hmsa airis ii 5.1 ortho protocols tmj t1 ge …...airis ii 5.1 ortho protocols tmj t1 ge coronal...

174
AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSA COR 3:50 2D GE/NORM 200 120 15 70 3 1 1 4/4 Interleved 256/160 OFF OFF 2 T E C H N I Q U E T A B S.Presat Inter. Walk Rephase Mode Bandwidth% AMI % Navi Echo MTC 0 OFF MANU/10 MANU/40 OFF OFF P A R T I C U L A R T A B Multi Echo 1 M A T R I X T A B Rect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap % OFF 100 OFF R-L AUTO 256 G A T I N G T A B Gating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/% OFF D Y N A M I C T A B Contrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save OFF OFF MANU 6 ISC ISC OFF F I L T E R T A B Truncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel OFF OFF ON OFF OFF AI3_E0 F A T S U P T A B Fat Sat Duration RF Amp% Freq. Graph Off. Freq. OFF O T H E R S T A B Carry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF Page 1 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality. If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Upload: others

Post on 22-Jun-2020

8 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINEHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 3:50 2D GE/NORM 200 120 15 70 3 1 1 4/4 Interleved 256/160 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI % Navi Echo MTC

0 OFF MANU/10 MANU/40 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF MANU 6

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 1 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 2: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols TMJ T1 GE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 3:50 2D GE/NORM 150 400 14 70 12 2 1 4/4 Interleved 224/192 OFF OFF 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI % Navi Echo MTC

0 OFF MANU/12 MANU/30 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 2 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 3: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols TMJ GE SAGITTAL KINEHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 3:50 2D GE/NORM 260 120 15 70 3 1 1 4/4 Interleved 256/160 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI % Navi Echo MTC

0 OFF MANU/10 MANU40 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF MANU 6

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 3 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 4: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols TMJ T2 FSE DE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:20 2D FSE/DE 150 5000 125 90 12 2 1 4/4 Interleved 224/160 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 19.9 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 125 19.9 16 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF MANU 6

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 4 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 5: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER SHIM CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR :26 2D SHIM/NORM 300 800 30 90 8 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF R-L AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF 1 ON

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL A-P ON A AUTO OFF Full OFF AUTO OFF

Page 5 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 6: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER SHIM SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG :16 2D SHIM/NORM 300 500 30 90 5 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF 1 ON

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL R-L ON A AUTO OFF Full OFF AUTO OFF

Page 6 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 7: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER SHIM TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS :38 2D SHIM/NORM 300 1200 30 90 12 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF 1 ON

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL F-H ON A AUTO OFF Full OFF AUTO OFF

Page 7 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 8: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER T1 SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:39 2D SE 200 520 20 90 14 1 1 4/5 Interleved 256/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/20 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3-_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 8 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 9: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER T1 SE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 6:30 2D SE 200 565 22 90 14 1 1 4/5 Interleved 256/192 OFF OFF 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/16 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 22 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 120 A-P MANU 512

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI1_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 9 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 10: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER T1 SE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 6:30 2D SE 180 565 22 90 14 1 1 4/5 Interleved 256/192 OFF OFF 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/16 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 22 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 120 A-P MANU 512

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI1_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 10 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 11: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER T1 COR HI-RES HMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 6:39 2D SE 200 520 20 90 14 1 1 4/5 Interleved 256/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/20 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 R-L MANU 512

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 11 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 12: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER PD SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:14 2D SE 200 1300 25 90 14 1 1 4/5 Interleved 256/192 3/4 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

1 OFF MANU/13 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 25 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 12 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 13: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER ME SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 8:56 2D SE 200 2000 25/80 90 14 1 2 4/5 Interleved 256/180 3/4 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% Bandwidth% AMI% Half Echo MTC

0 OFF MANU/13 MANU/8 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 TE 2 Multi Echo 25 80 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 13 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 14: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER T2 FSE DE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:42 2D FSE/DE 200 4500 125 90 14 1 1 4/5 Interleved 256/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

1 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 19 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 14 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 15: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER T2 FSE DE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:24 2D FSE/DE 200 4500 125 90 14 1 1 4/5 Interleved 256/192 OFF OFF 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 24 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 130 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 15 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 16: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER SHARED PD T2 CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:22 2D FSE/NORM 200 3500 25/125 90 14 1 2 4/5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 TE 2 Shot Num 1st E.Factor 2nd E.Factor IET E.Alloc Multi Echo 25 125 46 3 5 25 Share 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 120 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 16 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 17: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER SHARED PD T2 SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:22 2D FSE/NORM 200 3500 25/125 90 14 1 2 4/5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 TE 2 Shot Num 1st E.Factor 2nd E.Factor IET E.Alloc Multi Echo 25 125 46 3 5 25 Share 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 120 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 17 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 18: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER FIR CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:05 2D FIR/DE 200 3800 25 90/90 14 1 1 4.5/5 Interleved 256/176 1/2 OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num E.Factor IET E.Alloc E.Shift 25 22.7 24 4 25 Cent 0

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI4_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 18 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 19: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER FIR DE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 6:05 2D FIR/DE 200 3800 25 90/90 14 1 1 4.5/5 Interleved 256/176 1/2 OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num E.Factor IET E.Alloc E.Shift 25 22.7 24 4 25 Cent 0

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI4_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 19 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 20: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER IR CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 7:22 2D IR 220 2300 25 80 14 1 1 4/5 Interleved 256/160 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% MTC

0 OFF MANU/15 MANU/30 OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 20 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 21: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER FATSEP F CORONAL PDHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:48 2D FatSepF 200 2000 45 90 14 1 1 4/5 Interleved 256/224 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 27 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 45 27 144 2 45 Cent 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 130 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 21 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 22: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOUDLER FATSEP F CORONAL T2HMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:48 2D FatSepF 200 3100 90 90 14 1 1 4/5 Interleved 256/224 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 27 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 90 27 53 3 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 130 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 22 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 23: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER FATSEP F SAGITTAL PDHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:48 2D FatSepF 200 2000 45 90 14 1 1 4/5 Interleved 256/224 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 27 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 45 27 144 2 45 CENT 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 130 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 23 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 24: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER FATSEP F SAGITTAL T2HMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:48 2D FatSepF 200 3100 90 90 14 1 1 4/5 Interleved 256/224 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 27 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 90 27 53 3 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 130 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 24 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 25: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER FATSEP G SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:24 2D FatSepF/2pt 550 3100 17.1 90 14 1 1 4/5 Interleved 256/200 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/27 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 120 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 25 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 26: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER FATSEP G TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 4:24 2D FatSepF/2pt 550 3100 17.1 90 14 1 1 4/5 Interleved 256/200 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/27 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 120 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 26 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 27: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER FATSEP G TRS 3 PTHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 6:48 2D FatSepF/3pt 850 3100 28.5 90 14 1 1 4/5 Interleved 256/200 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/39 MANU/40 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 120 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 27 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 28: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER FATSEP S T1 TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:45 2D FatSepF/2pt 180 750 28 90 14 1 1 4/5 Interleved 224/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/25 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 120 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 28 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 29: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER T1 RSSG 3D TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi sl. Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:35 3D GE/RSSG 220 46 28 90 14 1 1 4/5 Interleved 256/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

1 OFF MANU/17 MANU/0 OFF OFF

P A R T I C U L A R T A BRF Angle Angle E.Alloc Multi Echo AUTO 117 SEQ 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 130 A-P MANU 512 35 MANU 16

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 29 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 30: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER 3D T2 SG TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 6:29 3D GE/SG 200 67 30 20 35 1 1 3/3 Interleved 256/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

1 OFF MANU/8 MANU/0 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %MANU 80 MANU RES 130 A-P MANU 512 35 MANU 16

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 30 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 31: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols SHOULDER 3D T2 GE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 6:29 3D GE/NORM 200 500 15 25 14 1 1 4/5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/0 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 130 A-P MANU 512 35 MANU 16

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 31 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 32: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW SHIM CORONAL HMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR :19 2D SHIM 300 600 30 90 6 1 1 10/10 Interleved 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF R-L AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF 1 ON

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL A-P ON A AUTO OFF Full OFF AUTO OFF

Page 32 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 33: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW T1 SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:52 2D SE 150 500 25 90 16 1 1 3.5/4 Interleved 256/176 OFF ON 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/10 MANU/40 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 25 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 33 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 34: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW T1 SE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:17 2D SE 150 550 15 90 16 1 1 3/3.5 Interleved 224/192 OFF ON 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/90 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 15 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 34 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 35: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW T1 SE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:46 2D SE 120 450 20 90 18 1 1 4/5 Interleved 224/192 OFF ON 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/14 MANU/40 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 35 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 36: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW ME SE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 7:41 2D SE 120 2400 20/90 90 18 1 1 4/5 Interleved 224/160 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% Bandwidth% Half Echo MTC

0 OFF MANU/15 MANU/7 OFF OFF

P A R T I C U L A R T A BTE 1 TE 2 Multi Echo 20 90 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 36 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 37: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW T2 FSE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:26 2D FSE/DE 150 3500 100 90 14 1 1 3.5/4 Interleved 256/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 34.1 OFF

P A R T I C U L A R T A BTE 1 TE 2 Shot Num E.Factor IET E.Alloc E.Shift Multi Echo 100 34.1 19 10 20 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 37 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 38: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW T2 FSE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:42 2D FSE/DE 120 4500 100 90 18 1 1 3/4 Interleved 256/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 34.1 OFF

P A R T I C U L A R T A BTE 1 TE 2 Shot Num E.Factor IET E.Alloc E.Shift Multi Echo 100 34.1 19 10 20 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 38 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 39: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW T2 FSE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:42 2D FSE/DE 120 4500 100 90 18 1 1 3/4 Interleved 256/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 34.1 OFF

P A R T I C U L A R T A BTE 1 TE 2 Shot Num E.Factor IET E.Alloc E.Shift Multi Echo 100 34.1 19 10 20 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 39 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 40: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW FATSEP G CORONAL MTCHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:46 2D FatSepG/2pt 150 900 17.1 90 16 1 1 3.5/4 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC Wave Duration RF.Amp Off.Freq

0 OFF MANU/27 MANU/30 OFF ON Sinc 10 12.7 1.2

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI2_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 40 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 41: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW FATSEP G CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 3:50 2D FatSepG/2pt 150 600 17.1 90 16 1 1 3.5/4 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/27 MANU/30 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI2_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 41 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 42: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW IR CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:29 2D IR 150 1800 25 90 14 1 1 3.5/4 Interleved 224/160 3/4 OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/10 MANU/40 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 180 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 42 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 43: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW T2 GE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:24 2D GE/NORM 150 500 11 25 16 1 1 3.5/4 Interleved 224/192 3/4 OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/14 MANU/40 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 43 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 44: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW T2 GE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:33 2D GE/SG 150 520 14 25 18 1 1 4/5 Interleved 224/160 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/20 MANU/0 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 44 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 45: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ELBOW 3D SG CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 8:00 3D GE/SG 150 50 20 20 40 1 1 2/2 Interleved 256/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/8 MANU/40 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 150 H-F AUTO 256 40 MANU 16

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 45 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 46: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST SHIM CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR :10 2D SHIM/NORM 300 300 30 90 3 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF R-L AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF 1 ON

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL A-P ON A AUTO OFF Full OFF AUTO OFF

Page 46 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 47: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST TRS SHIMHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS :26 2D SHIM/NORM 300 800 30 90 8 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF 1 ON

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL F-H ON A AUTO OFF Full OFF AUTO OFF

Page 47 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 48: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T1 SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:23 2D SE 130 420 20 90 11 1 1 2.5/3.5 Interleved 256/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/18 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 48 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 49: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T1 SE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:29 2D SE 130 350 20 90 14 1 1 3/3.5 Interlev/2 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/18 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 49 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 50: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T1 SE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:36 2D SE 130 350 20 90 14 1 1 3/4 Interlev/2 256/240 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/18 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 50 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 51: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST ME SE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:36 2D SE 130 2800 20/90 90 14 1 2 3/4 Interleved 224/160 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/7 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 TE 2 Multi Echo 20 90 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 51 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 52: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T2 FSE DE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:55 2D FSE/DE 130 3700 100 90 11 1 1 2.5/3.5 Interleved 256/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 TE 2 Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 100 22.7 24 8 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 52 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 53: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T2 FSE DE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:24 2D FSE/DE 130 4500 100 90 14 1 1 3/4 Interleved 256/192 OFF OFF 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 100 22.7 24 8 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 53 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 54: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST SHARED PD T2 CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:24 2D FSE/DE 130 3000 25/100 90 11 1 2 2.5/3.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 TE 2 Level% Shot Num. 1st E.Factor 2nd E.Factor IET E.Alloc Multi Echo 100 125 22.7 54 3 6 25 Share 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 170 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 54 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 55: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST SHARED PD T2 TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 4:48 2D FSE/NORM 130 4500 25/125 90 14 1 2 3/4 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 TE 2 Level% Shot Num. 1st E.Factor 2nd E.Factor IET E.Alloc Multi Echo 100 125 22.7 32 3 6 25 Share 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 55 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 56: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST IR CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:24 2D IR 130 2000 25 90 11 1 1 2.5/3.5 Interleved 224/160 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% Level% Half Echo MTC

0 OFF MANU/14 MANU/20 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 1 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 56 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 57: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST FATSEP F CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:48 2D FatSepF 130 3000 90 90 11 1 1 2.5/3.5 Interleved 256/192 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 27 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num E.Factor IET E.Alloc E.Shift Org.Image Calc Image 90 27 48 4 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 57 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 58: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST FATSEP F TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:17 2D FatSepF 130 3300 90 90 14 1 1 3/4 Interleved 256/192 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 27 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num E.Factor IET E.Alloc E.Shift Org.Image Calc Image 90 27 48 4 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 58 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 59: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST FATSEP G TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:17 2D FatSepG 130 550 17.1 90 14 1 1 3/4 Interleved 256/200 ON OFF 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/28 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI2_E1

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 59 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 60: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST FATSEP S CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:34 2D FatSepS 130 550 24 90 11 1 1 2.5/3.5 Interleved 256/192 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/27 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 260 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 60 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 61: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T1 3D RSSG CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:57 3D GE/RSSG 130 45 18 90 25 1 1 2/2 Interleved 256/176 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/0 OFF OFF

P A R T I C U L A R T A BRF Phase Angle E.Alloc Multi Echo

AUTO 117 SEQ 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 150 H-F MANU 256 25 MANU 16

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 61 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 62: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T2 3D SG CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:11 3D GE/SG 140 65 30 20 25 1 1 2/2 Interleved 256/176 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/16 MANU/20 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 130 H-F MANU 512 25 MANU 24

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 62 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 63: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T2 GE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:29 2D GE/SG 140 350 15 25 11 1 1 2.5/3.5 Interleved 224/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/0 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 63 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 64: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T2 GE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:48 2D GE/NORM 130 500 15 25 14 1 1 3/3.5 Interleved 256/192 OFF OFF 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/17 MANU/0 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 64 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 65: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T2 GE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:26 2D GE/SG 130 500 15 25 14 1 1 3/3.5 Interleved 224/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/0 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 170 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 65 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 66: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST SHIM COR KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR :10 2D SHIM 300 300 30 90 3 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% AMI% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF R-L AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF 1 ON

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF 0 OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL A-P ON A AUTO OFF Full OFF AUTO OFF

Page 66 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 67: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST SHIM TRS KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS :26 2D SHIM/NORM 300 800 30 90 8 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% AMI% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF 1 ON

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF 0 OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL F-H ON A AUTO OFF Full OFF AUTO OFF

Page 67 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 68: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T1 SE SAG KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:29 2D SE 140 350 20 90 14 1 1 3/3.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/18 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 68 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 69: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T1 SE TRS KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:14 2D SE 140 350 20 90 14 1 1 3/4 Interlev/2 256/224 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/18 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 69 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 70: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T1 SE COR KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:23 2D SE 140 420 20 90 14 1 1 3/3.5 Interlev/2 256/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/18 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 70 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 71: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST ME SE TRS KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 8:58 2D SE 140 2800 20/90 90 14 1 2 3/4 Interleved 224/160 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/7 MANU/.30 OFF OFF

P A R T I C U L A R T A BTE 1 TE 2 Multi Echo 20 90 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 71 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 72: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T2 FSE DE COR KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:55 2D FSE/DE 140 3700 100 90 11 1 1 3/3.5 Interleved 256/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num. E.Factor IET E.Alloc E.Shift Multi Echo 100 22.7 24 8 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 72 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 73: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST T2 FSE TRS KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:24 2D FSE/DE 140 4500 100 90 14 1 1 3/4 Interleved 224/192 OFF OFF 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 19.9 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num. E.Factor IET E.Alloc E.Shift Multi Echo 100 19.9 24 8 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 73 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 74: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST SHARED COR KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:24 2D FSE/NORM 140 3000 25/125 90 11 1 2 3/3.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 TE 2 Level% Shot.Num 1st E.Factor 2nd E.Factor IET E.Alloc Multi Echo 25 125 22.7 54 3 6 25 Share 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU RES 170 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 74 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 75: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST SHARED TRS KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 4:48 2D FSE/NORM 140 4500 25/125 90 14 1 2 3/4 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 TE 2 Level% Shot.Num 1st E.Factor 2nd E.Factor IET E.Alloc Multi Echo 25 125 22.7 32 3 6 25 Share 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 75 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 76: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST IR CORONAL KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:24 2D FSE/NORM 140 2000 25 90 11 1 1 3/3.5 Interleved 224/160 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/14 MANU/30 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 76 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 77: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST FATSEP F COR KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:48 2D FatSepF 140 3000 90 90 11 1 1 3/3.5 Interleved 224/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 23.6 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num. E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 90 23.6 48 4 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 77 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 78: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols WRIST FATSEP F TRS KNEE COILHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:17 2D FatSepF 140 3300 90 90 11 1 1 3/3.5 Interleved 224/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 23.6 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num. E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 90 23.6 48 4 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF 100 MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 78 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 79: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND SHIM CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR :44 2D SHIM 300 300 30 90 3 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 38.3 OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF 0 OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL A-P ON A AUTO OFF Full OFF AUTO OFF

Page 79 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 80: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND SHIM TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 1:16 2D SHIM 300 800 30 90 8 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 38.3 OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF 0 OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL F-H ON A AUTO OFF Full OFF AUTO OFF

Page 80 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 81: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND T1 SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:46 2D SE 200 450 20 90 11 1 1 3/3.5 Interleved 256/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/18 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 81 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 82: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND T1 SE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:07 2D SE 130 400 20 90 20 1 1 3/3.5 Interlev/2 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/18 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 82 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 83: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND T1 SE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 6:24 2D SE 150 400 20 90 20 1 1 3/3.5 Interlev/2 256/240 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/18 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 83 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 84: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND ME SE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 8:58 2D SE 150 2800 20/90 90 20 1 2 3/3.5 Interleved 256/240 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/7 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 TE 2 Multi Echo 20 90 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 84 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 85: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND T2 FSE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 3:52 2D FSE/DE 150 6100 125 90 20 1 1 3/3.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 19 10 25 Seq 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 85 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 86: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND FATSEP G TRS HMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:00 2D FatSepG 150 750 17 90 20 1 1 3/3.5 Interleved 256/200 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/28 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC L T E R T OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 86 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 87: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND IR CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:24 2D IR 200 2000 25 90 12 1 1 3/4 Interleved 256/160 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/14 MANU/30 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC L T E R T OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 87 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 88: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND 3D T1 RSSG CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:17 3D GE/RSSG 200 45 18 50 25 1 1 2/2 Interleved 256/176 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/0 OFF OFF

P A R T I C U L A R T A BRF Phase Angle E.Alloc Multi Echo

AUTO 117 SEQ 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 130 R-L MANU 256 25 MANU 16

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC L T E R T OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 88 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 89: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND T2 3D SG CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:11 3D GE/SG 200 65 30 20 25 1 1 2/2 Interleved 256/176 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/8 MANU/0 OFF OFF

P A R T I C U L A R T A BRF Phase Angle E.Alloc Multi Echo

AUTO 117 SEQ 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 130 R-L MANU 256 25 MANU 16

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC L T E R T OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 89 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 90: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HAND T2 GE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 6:43 2D GE/NORM 130 700 15 25 20 1 1 3/3.5 Interleved 256/192 OFF OFF 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/17 MANU/0 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 90 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 91: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP SHIM TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS :45 2D SHIM 300 1400 30 90 14 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF 0 OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL F-H ON A AUTO OFF Full OFF AUTO OFF

Page 91 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 92: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP T1 SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:29 2D SE 380 350 20 90 15 1 1 4/5 Interlev/2 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/20 MANU/20 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU TM/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI2_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 92 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 93: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP T1 SE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:07 2D SE 300 400 20 90 20 1 1 4.5/5.5 Interlev/2 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/20 MANU/20 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI2_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 93 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 94: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP T1 SE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:07 2D SE 300 400 20 90 20 1 1 4/5 Interlev/2 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/20 MANU/20 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI2_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 94 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 95: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP T2 FSE DE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:17 2D FSE/DE 380 4600 125 90 15 1 1 4/5 Interleved 256/192 OFF OFF 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc Multi Echo 125 22.7 23 10 25 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 120 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 95 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 96: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP T2 FSE DE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:05 2D FSE/DE 380 6100 125 90 20 1 1 4/5 Interleved 256/256 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc Multi Echo 125 22.7 23 10 25 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 96 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 97: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP FIR DE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:35 2D FIR/DE 380 4300 25 90/90 15 1 1 4/5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift 25 22.7 32 6 25 Cent 0

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 97 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 98: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP FATSEP F TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:29 2D FatSepF 380 5300 90 90 20 1 1 4/5 Interleved 256/220 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 27 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 90 27 31 4 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 98 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 99: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP FATSEP G TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:52 2D FatSepG 380 400 17.1 90 20 1 1 4/5 Interlev/2 256/220 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/27 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 99 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 100: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP FATSEP G TRS 3PTHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 9:32 2D/3PT FatSepG 380 650 28.5 90 20 1 1 4/5 Interlev/2 256/220 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/31 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 100 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 101: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP T2 GE SG TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:22 2D GE/SG 380 650 15 25 20 1 1 4/5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/0 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Res 130 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 101 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 102: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP UNILAT T1 SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:46 2D SE 240 300 20 90 15 1 1 4/5 Interlev/2 224/180 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/20 MANU/20 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Res 160 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 102 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 103: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP UNILAT T1 SE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:56 2D SE 240 330 20 90 18 1 1 4/5 Interlev/2 224/180 OFF ON 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/20 MANU/20 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Res 150 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 103 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 104: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP UNILAT T1 SE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:56 2D SE 240 360 20 90 20 1 1 4/5 Interleved 224/180 OFF ON 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/20 MANU/20 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Res 130 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 104 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 105: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP UNILAT T2 FSE DE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:04 2D FSE/DE 240 4000 100 90 15 1 1 4/5 Interleved 224/192 OFF ON 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 29.9 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 100 29.9 38 10 20 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Res 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 105 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 106: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP UNILAT T2 FSE DE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:42 2D FSE/DE 240 4500 100 90 18 1 1 4/5 Interleved 224/192 OFF OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 29.9 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 100 29.9 19 10 20 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 106 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 107: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP UNILAT T2 FSE DE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:40 2D FSE/DE 240 5000 100 90 20 1 1 4/5 Interleved 224/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 29.9 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 100 29.9 34 10 20 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MAN RES 180 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON 0 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 107 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 108: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP UNILAT IR CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:24 2D IR 260 1500 20 90 15 1 1 4.5/5 Interleved 224/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/14 MANU/40 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MAN RES 160 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 1 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 108 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 109: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP UNILAT FIR CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:34 2D FIR 260 3800 20 90/90 15 1 1 4.5/5 Interleved 224/160 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 29.9 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift 20 29.9 44 6 20 Cent 0

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MAN RES 170 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 109 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 110: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols HIP UNILAT FATSEP F CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:02 2D FatSepF 260 4200 90 90 15 1 1 4.5/5 Interleved 224/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 23.6 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 90 23.6 72 4 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MAN RES 180 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 110 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 111: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE SHIM CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR :26 2D SHIM 300 800 30 90 8 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL A-P ON A AUTO OFF Full OFF AUTO OFF

Page 111 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 112: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE SHIM SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG :19 2D SHIM 300 600 30 90 6 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL R-L ON A AUTO OFF Full OFF AUTO OFF

Page 112 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 113: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE SHIM TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS :38 2D SHIM 300 1200 30 90 12 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL F-H ON A AUTO OFF Full OFF AUTO OFF

Page 113 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 114: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE T1 SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:08 2D SE 180 350 20 90 18 1 1 3.5/4.5 Interleved 256/220 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/18 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L MANU 512

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI1_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 114 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 115: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE PD SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 7:41 2D SE 180 1200 25 90 18 1 1 3.5/4.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/14 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 25 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI1_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 115 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 116: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE ME SE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 9:11 2D SE 180 2600 20 90 20 1 2 3.5/4.5 Interleved 256/180 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% Bandwidth% AMI% Half Echo MTC

0 OFF MANU/20 MANU/7 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 TE 2 Multi Echo 20 90 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 116 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 117: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE T2 FSE DE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:28 2D FSE/DE 180 6100 125 90 20 1 1 3.5/4.5 Interleved 256/224 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 22 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 117 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 118: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE T2 FSE DE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:28 2D FSE/DE 180 6100 125 90 20 1 1 3.5/4.5 Interleved 256/224 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 22 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 118 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 119: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE T2 FSE DE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 4:05 2D FSE/DE 160 5100 100 90 20 1 1 4/5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 24 8 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 119 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 120: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE SHARED PD T2 CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:34 2D FSE 180 3800 25/125 90 18 1 2 3.5/4.5 Interleved 256/224 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 TE 2 Level% Shot.Num 1stE.Factor 2ndE.Factor IET Multi Echo 25 125 22.7 44 3 5 25 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 120 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 121: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE SHARED PD T2 SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 6:10 2D FSE 180 4200 25/125 90 20 1 2 3.5/4.5 Interleved 256/224 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 TE 2 Level% Shot.Num 1stE.Factor 2ndE.Factor IET Multi Echo 25 125 22.7 44 3 5 25 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 121 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 122: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE T1 SE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:20 2D SE 180 400 20 90 20 1 1 3.5/4.5 Interlev/2 256/200 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/18 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI1_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 122 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 123: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE FIR DE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:24 2D FIR 180 4000 20 100/90 18 1 1 3.5/4.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 34.1 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift 20 34.1 48 4 20 Cent 0

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 123 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 124: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE FIR DE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 7:02 2D FIR 180 4400 20 100/90 20 1 1 3.5/4.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 34.1 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift 20 34.1 48 4 20 Cent 0

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 124 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 125: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE IR CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI MultiSlice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:56 2D IR 180 2000 25 90 18 1 1 3.5/4.5 Interleved 256/160 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/14 MANU/30 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 110 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

ON OFF ON 1 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 125 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 126: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE 3D PBSG SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:56 3D GE/PBSG 180 16 8 90 32 1 1 3/3 Single 256/256 1/2 OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% Half Echo #RF Prep MTC

0 OFF MANU/30.7 OFF 20 OFF

P A R T I C U L A R T A BRF Phase Angle E.Alloc

MANU 180 SEQ

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256 32 MANU 20

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI1_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 126 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 127: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE 3D RSSG SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 6:24 3D GE/RSSG 180 40 14 45 60 1 1 1.7 Interleved 256/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/12 MANU/40 OFF OFF

P A R T I C U L A R T A BRF Phase Angle E.Alloc Multi Echo

AUTO 117 SEQ 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256 60 MANU 20

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 127 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 128: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE T2 3D SG SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 6:24 3D GE/SG 180 40 16 25 50 1 1 2/2 Interleved 256/192 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/0 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256 100 MANU 20

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI2_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 128 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 129: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE T2 SG TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 4:48 2D GE/SG 160 500 15 25 15 1 1 4/5 Interleved 256/192 OFF OFF 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/0 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 129 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 130: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE FATSEP F CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:42 2D FatSepF 180 4400 90 90 18 1 1 3.5/4.5 Interleved 256/224 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

1 OFF 27 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 90 27 32 4 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 130 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 131: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE FATSEP F SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:20 2D FatSepF 180 5000 90 90 20 1 1 3.5/4.5 Interleved 256/224 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

1 OFF 27 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 90 27 32 4 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 131 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 132: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE FATSEP G SAGITTAL MTCHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 7:02 2D FatSepG 180 1100 17.1 90 20 1 1 3.5/4.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC Wave Duration RF.Amp Off.Freq

0 OFF MANU/33.8 MANU/0 OFF ON Sinc 10 12.7 1.2

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI2_E1

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 132 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 133: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE FATSEP G SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:56 2D FatSepG 180 740 17.1 90 20 1 1 3.5/4.5 Interleved 256/200 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/28 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI2_E1

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 133 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 134: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols KNEE FATSEP G SAGITTAL 3PTHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 8:00 2D/3PT FatSepG 180 1200 28.5 90 20 1 1 3.5/4.5 Interleved 256/200 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/51 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI2_E1

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 134 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 135: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE SHIM SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG :16 2D SHIM 300 500 30 90 5 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL R-L ON A AUTO OFF Full OFF AUTO OFF

Page 135 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 136: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE SHIM TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS :22 2D SHIM 300 700 30 90 7 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL F-H ON A AUTO OFF Full OFF AUTO OFF

Page 136 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 137: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE 3D PBSG SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:01 3D GE/PBSG 180 16 8 90 26 1 1 3/3 Single 256/256 1/2 OFF 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% Half Echo #RF Prep MTC

0 OFF MANU/30.7 OFF 20 OFF

P A R T I C U L A R T A BRF Phase Angle E.Alloc

MANU 180 SEQ

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256 26 MANU 20

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI1_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 137 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 138: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE 3D T2 GE SG SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:01 3D GE/SG 180 60 30 20 40 1 1 2/2 Interleved 256/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/9 MANU/30 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 130 A-P AUTO 256 40 MANU 10

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 138 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 139: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE FIR CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:36 2D FIR 180 3500 25 100/90 16 1 1 4/4.5 Interleved 256/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift 25 22.7 96 2 25 SEQ 0

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 120 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 1 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 139 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 140: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE FIR SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:36 2D FIR 180 3500 25 100/90 16 1 1 4/4.5 Interleved 256/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift 25 22.7 96 2 25 SEQ 0

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 120 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 1 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 140 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 141: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE FATSEP F CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:24 2D FatSepF 160 4500 90 90 16 1 1 4/4.5 Interleved 256/192 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 27 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 90 27 72 4 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 150 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 141 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 142: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE FATSEP F SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:24 2D FatSepF 160 4500 90 90 16 1 1 4/4.5 Interleved 256/192 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 27 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Org.Image Calc.Image 90 27 72 4 45 SEQ 0 ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 150 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 142 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 143: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE FATSEP G SAGITTAL 2PTHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:00 2D/PT FatSepG 180 600 17.1 90 16 1 1 3/3.5 Interleved 256/200 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/28 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI1_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 143 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 144: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE FATSEP G SAGITTAL 3PTHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 6:24 2D/3PT FatSepG 180 960 28.5 90 16 1 1 3/3.5 Interleved 224/200 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/40 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI1_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 144 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 145: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE IR CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:24 2D IR 180 2000 25 90 16 1 1 4/4.5 Interleved 256/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/10 MANU/40 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 120 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 1 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 145 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 146: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE IR SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 6:24 2D IR 180 2000 25 90 16 1 1 4/4.5 Interleved 256/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/10 MANU/40 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 120 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON 1 OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 146 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 147: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE PD FSE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:34 2D FSE/NORM 160 2200 25 90 16 1 1 4/4.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 25 22.7 76 4 25 Cent 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 160 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 147 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 148: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE PD FSE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:34 2D FSE/NORM 180 2200 25 90 16 1 1 3/3.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 25 22.7 76 4 25 Cent 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 160 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 148 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 149: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE SHARED PD T2 CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:48 2D FSE/NORM 160 3000 25/75 90 16 1 2 4/4.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 TE 2 Level% Shot.Num 1st.Efactor 2ndE.Factor IET E.Alloc Multi Echo 25 75 22.7 48 2 4 25 Share 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 149 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 150: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE SHARED PD T2 SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:48 2D FSE/NORM 180 3000 25/75 90 16 1 2 4/4.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 TE 2 Level% Shot.Num 1st.Efactor 2ndE.Factor IET E.Alloc Multi Echo 25 75 22.7 48 2 4 25 Share 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 150 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 151: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE T1 SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:22 2D SE 160 300 20 90 16 1 1 4/4.5 Interleved 256/192 OFF ON 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/21 MANU/20 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 140 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI2_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 151 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 152: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE T1 SE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:22 2D SE 180 300 20 90 16 1 1 3/3.5 Interleved 256/192 OFF ON 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/21 MANU/20 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 140 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI2_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 152 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 153: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE T1 SE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:22 2D SE 160 350 20 90 18 1 1 4/4.5 Interleved 256/192 OFF ON 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/21 MANU/20 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 20 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 120 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI2_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 153 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 154: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE T2 FSE DE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:40 2D FSE/DE 160 5000 125 90 16 1 1 4/4.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 34 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 180 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 154 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 155: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE T2 FSE DE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:40 2D FSE/DE 180 5000 125 90 16 1 1 3/3.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 34 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 180 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 155 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 156: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE T2 FSE DE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:08 2D FSE/DE 160 5500 125 90 18 1 1 4/5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 OFF 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 28 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 150 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 156 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 157: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE T2 GE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 5:18 2D GE/NORM 180 520 14 30 16 1 1 3/3.5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/15 MANU/40 OFF OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 28 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 160 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 157 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 158: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE T2 GE SAGITTAL MTCHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:58 2D GE/NORM 180 800 15 50 16 1 1 3/3.5 Interleved 224/192 3/4 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC Wave Duration RF Amp Off Freq

0 OFF MANU/16 MANU/30 OFF ON Sinc 10 12.7 1.2

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 130 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 158 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 159: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE T2 GE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:37 2D GE/NORM 160 550 15 30 16 1 1 4/5 Interleved 256/192 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/20 MANU/20 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 160 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 159 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 160: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE T2 GE TRS MTCHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 5:35 2D GE/NORM 160 900 15 50 18 1 1 4/5 Interleved 224/192 3/4 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC Wave Duration RF.Amp Off.Freq

0 OFF MANU/16 MANU/30 OFF ON Sinc 10 12.7 1.2

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 130 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 160 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 161: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols ANKLE T2 ME TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 6:56 2D SE 180 2000 20/90 90 18 1 2 4/4.5 Interleved 224/176 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% Bandwidth AMI% Half Echo MTC

0 OFF MANU/28 MANU/14 MANU/0 OFF OFF

P A R T I C U L A R T A BTE 1 TE2 Multi Echo 20 90 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 161 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 162: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT SHIM TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS :22 2D SHIM 300 700 30 90 7 1 1 10/10 Sequential 64/32 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% Navi Echo MTC

0 OFF 38.3 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF A-P AUTO 64

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF OFF OFF

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL F-H ON A AUTO OFF Full OFF AUTO OFF

Page 162 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 163: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT 3D RSSG SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 6:39 3D GE/RSSG 220 40 18 45 48 1 1 1.5 Interleved 256/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/13 MANU/40 OFF OFF

P A R T I C U L A R T A BRF Phase Angle E.Alloc Multi Echo

AUTO 117 SEQ 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 130 A-P AUTO 256 48 MANU 10

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 163 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 164: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT 3D T2 SG SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI S.Encode Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 8:19 3D GE/SG 220 60 30 20 40 1 1 2 Interleved 256/160 OFF OFF 1

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/7 MANU/40 OFF OFF

P A R T I C U L A R T A BMulti Echo

1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 130 A-P AUTO 256 40 MANU 16

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 164 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 165: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT FATSEP G SAGITTAL 2PTHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:40 2D FatSepG 220 700 17.1 90 18 1 1 3/4 Interleved 256/200 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/28 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI1_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 165 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 166: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT FATSEP G SAGITTAL 3PTHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 7:20 2D/3PT FatSepG 220 1100 28.5 90 18 1 1 3/4 Interleved 256/200 OFF OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/51 MANU/20 OFF OFF

P A R T I C U L A R T A BOrg.Image Calc.Image

ON Ad/Sb

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 H-F AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI1_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 166 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 167: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT IR CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 6:24 2D IR 220 2000 25 80 15 1 1 4/4.5 Interleved 256/160 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/10 MANU/40 OFF OFF

P A R T I C U L A R T A B

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 167 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 168: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT T1 SE CORONALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 4:13 2D SE 220 550 15 80 15 1 1 3/4 Interleved 256/192 1/2 OFF 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/12 MANU/90 ON OFF

P A R T I C U L A R T A BTE 1 Multi Echo 15 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 120 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 168 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 169: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT T1 SE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 4:54 2D SE 220 320 15 90 18 1 1 3/4 Interleved 256/192 OFF ON 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/13 MANU/90 ON OFF

P A R T I C U L A R T A BTE 1 Multi Echo 15 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 120 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 169 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 170: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT T1 SE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 6:24 2D SE 150 500 25 90 20 1 1 4/5 Interleved 224/192 OFF ON 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% AMI% Half Echo MTC

0 OFF MANU/9 MANU/40 OFF OFF

P A R T I C U L A R T A BTE 1 Multi Echo 25 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 170 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 171: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT T2 FSE TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 7:44 2D FSE/DE 150 6100 125 90 20 1 1 4/5 Interleved 256/192 OFF ON 4

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 ON FREQ 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 19 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU Tm/Rs 200 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 171 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 172: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT T2 FSE SAGITTALHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSASAG 6:36 2D FSE/DE 220 5500 125 90 18 1 1 3/4 Interleved 256/192 OFF ON 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 ON FREQ 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 24 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 130 A-P AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL L-R ON A AUTO AUTO Full OFF AUTO OFF

Page 172 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 173: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT T2 FSE CORHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSACOR 5:31 2D FSE/DE 220 4600 125 90 15 1 1 3/4 Interleved 256/192 OFF ON 3

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Level% MTC

0 ON FREQ 22.7 OFF

P A R T I C U L A R T A BTE 1 Level% Shot.Num E.Factor IET E.Alloc E.Shift Multi Echo 125 22.7 24 10 25 SEQ 0 1

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF MANU RES 130 R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL P-A ON A AUTO AUTO Full OFF AUTO OFF

Page 173 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009

Page 174: HMSA AIRIS II 5.1 Ortho Protocols TMJ T1 GE …...AIRIS II 5.1 Ortho Protocols TMJ T1 GE CORONAL KINE HMSA QS4 DM# 60248 B A S I C T A B Scan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2

AIRIS II 5.1 Ortho Protocols FOOT T2 ME TRSHMSA

QS4 DM# 60248

B A S I C T A BScan Scan Time 2D/3D Pulse seq. FOV TR TE1/TE2 FA/TI Multi Slice Angle Multi Echo Thick/Int. Multi scan Freq/Phase Half Scan Dual Slice NSATRS 8:19 2D SE 150 2600 20/90 90 20 1 1 4/5 Interleved 224/160 1/2 ON 2

T E C H N I Q U E T A BS.Presat Inter. Walk Rephase Mode Bandwidth% Bandwidth AMI% Half Echo MTC

0 OFF MANU/15 MANU/7 MANU/30 OFF OFF

P A R T I C U L A R T A BTE 1 TE 2 Multi Echo 20 90 2

M A T R I X T A BRect FOV Rect. % Anti-aliasing Mode % Phase Dir. Recon Matrix Number 3D Slice # Slice Reject Rate % Overlap %

OFF OFF R-L AUTO 256

G A T I N G T A BGating Gate Mode Navi Gate Gate Win. Navi# TR Beat Rate Count Multi-phase Segment Number Card Phases Delay (ms) Interval (ms) Echo Alloc. Echo Shift G. Margin/%

OFF

D Y N A M I C T A BContrast Travel time Int. Pause S.W. time Breathhold Fluoro # Dynamic Start (sec) 1st Number 2nd Number 3rd Number 3rd Interval Update Scr. Image Sub. Image Disk Save

OFF OFF

ISCISC OFF

F I L T E R T A BTruncation Shading Correction Adaptive k space FOV Filter T2 correct. Level % T2 Target FOV Adp.Sel

OFF OFF ON OFF AI3_E0

F A T S U P T A BFat Sat Duration RF Amp% Freq. Graph Off. Freq.

OFF

O T H E R S T A BCarry Offset Line/Box Inf. FOV Stack Mode Slice Order Gap Int. Rcoil Mode Prescan Vol. Shim Oblique Check Seq. Voice F-Search

MAG LINE YES NORMAL H-F ON A AUTO AUTO Full OFF AUTO OFF

Page 174 of 174 Caution: These HMSA recommended protocols have been tested and proven to deliver good image quality.

If the user deviates from these recommended protocols, HMSA cannot guarantee image quality. 2/24/2009