CURSO DE OPERACIÓN Y MANTENIMIENTO
RADIOFARO OMNIDIRECCIONAL VHF CONVENCIONAL (CVOR)
SELEX Sistemi Integrati Inc.11300 West 89th Street
Overland Park, KS 66214USA
T: 1-913-495-2600
![Page 2: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/2.jpg)
• Localizar cada ensamblaje principal del Equipo CVOR 1150, explicar la función de cada, y explicar su contribución al flujo de señales.
• Operar y alinear el equipo CVOR según las especificaciones del fabricante.
• Reconocer condiciones de falla y corregir la causa al nivel de modulo o Unidad Reemplazable en Sitio (LRU).
OBJECTIVOS DEL CURSO
![Page 3: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/3.jpg)
LECTURA
REVISION DE TEORIA BASICA DE CVOR
![Page 4: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/4.jpg)
INSTALACION TIPICA DE ESTACION DE CVOR CON GROUND CHECK AUTOMATICO
![Page 5: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/5.jpg)
OBJECTIVOS DE LA REVISION DE TEORIA BASICA DE CVOR
• La exigencia por VOR• Espectro RF punto de vista de la aeronave• La relación de fase entre los componentes AM y FM.• Como se produce cada componente en un sistema
CVOR.• Las tres salidas de RF del transmisor• Las características de cada salida de banda lateral
![Page 6: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/6.jpg)
TYPICAL ON-BOARD INDICATORS
SOLO VOR VOR CON ILS
![Page 7: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/7.jpg)
COMPARANDO LAS DOS SEÑALES DE 30 Hz EN DIFERENTES ACIMUTES
NORTEEL RADIAL
0 GRADOS
LAS SEÑALES AM Y FM CON
LA MISMA FASE
ESTEEL RADIAL 90 GRADOS
LA AM ATRASA LA FM POR 90 GRADOS
SUREL RADIAL
180 GRADOS LA AM
ATRASA LA FM POR 180
GRADOS
OESTEEL RADIAL
270 GRADOS LA AM
ATRASA LA FM POR 270
GRADOS
![Page 8: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/8.jpg)
ORIGEN DEL COMPONENTE 30 Hz AM
RF MODULADO POR SEÑAL DE
AUDIO 30 Hz
SEÑAL DE AUDIO 30 Hz DEL RF
DETECTADO
![Page 9: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/9.jpg)
ORIGEN DEL COMPONENTE 30 Hz FM
SEÑAL DE AUDIO 9960 Hz CON
MODULACION DE FRECUENCIA
30 Hz
SEÑAL DE AUDIO 30 Hz DISCRIMINADO DE LA SEÑAL DE AUDIO 9960 Hz
9960 9480 9960 10440 9960
![Page 10: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/10.jpg)
SEÑAL DE UN VOR DESDE EL PUNTO DE VISTA DE LA AERONAVE (ANALIZADOR DE ESPECTRO)
![Page 11: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/11.jpg)
CONCEPTO SIMPLIFICADO DE RADIACION DE CVOR
ANTENA CVOR
PATRON DE RADIACION LIMACON
Componente FM (Referencia):
Portadora RF con bandas laterales de 9960Hz AM, variando su frecuencia con forma sinusoidal de 30Hz
Componente AM (Variable) es formado por la rotacion horaria en frecuencia de 30Hz.
![Page 12: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/12.jpg)
LECTURA
ANTENA LAZO ALFORD
![Page 13: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/13.jpg)
OBJECTIVOS DE LA LECTURA DE LA ANTENA LAZO ALFORD
• La forma fisica de la Antena Lazo Alford • La teoria de propagacion de la antena Lazo
Alford• Puntos de ajuste de la Antena Lazo Alford • La forma fisica del puente coaxial• La teoria basica del puente coaxial
![Page 14: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/14.jpg)
VISTA SUPERIOR DE LA ANTENA LAZO ALFORD
Condensador de aire dielectrico
Condensador de aire dielectrico
Platos Extremos
![Page 15: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/15.jpg)
RED DE ACOPLAMIENTO DE IMPEDANCIA
Conector de la antena J1
Pieza de Posicionamiento
Codo
Cabo Sintonizador
Cable de alimentacion del Transmisor
![Page 16: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/16.jpg)
CORRIENTE EN CADA ELEMENTO
ASUMA DIFERENCIA DE
FASE ENTRE LOS DOS DIPOLOS
DOBLADOS DE 180 GRADOS.
![Page 17: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/17.jpg)
CORRIENTES INTERNAS
![Page 18: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/18.jpg)
CORRIENTES RESTANTES CON LAS CORRIENTES INTERNAS ANULADAS
![Page 19: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/19.jpg)
ARMARIO INTERFAZ
![Page 20: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/20.jpg)
PUENTE COAXIAL
![Page 21: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/21.jpg)
PUENTE COAXIAL
![Page 22: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/22.jpg)
MEZCLANDO CSB CON SBO
0 DEGREES 180 DEGREES
MODULATED RF
SIDEBAND ONLY
![Page 23: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/23.jpg)
PUENTE COAXIAL
CSB+SB1CSB-SB1CSB+SB2
CSB-SB2
![Page 24: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/24.jpg)
SISTEMA DE CUATRO LAZOS – PAR NUMERO 1
NW
SE
Por motivo que las dos antena tienen fase opuesta, el patron que se forma es de dos lobulos, con un nulo de RF entre los dos.
![Page 25: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/25.jpg)
SISTEMA DE CUATRO LAZOS – PAR NUMERO 1
NW
SE
Por motivo que las bandas laterales de 30Hz tienen fase opuesta, cuando una antena esta en la porcion de alta amplitud, la otra antena esta en su porcion de baja amplitud.
![Page 26: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/26.jpg)
SISTEMA DE CUATRO LAZOS – PAR NUMERO 1
NW
SE
Por eso, una aeronave al Noroeste recibiria una senal de 30Hz AM con fase opuesta del que esta al Sudeste.
![Page 27: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/27.jpg)
SISTEMA DE CUATRO LAZOS – PAR NUMERO 2
NE
SW
El otro par tiene el mismo efecto en la dirección NE/SW.
![Page 28: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/28.jpg)
SISTEMA DE CUATRO LAZOS – SUMA DE LOS DOS PARES
NW
SEPara las naves que no están en los nulos, la fuerza de campo del patrón es la suma de los dos.
![Page 29: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/29.jpg)
SUMA DE LOS CUATRO PATRONES
NW
SE
La suma de los dos patrones forma un limacon. NE
SW
![Page 30: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/30.jpg)
LAS TRES SALIDAS DEL ARMARIO DEL CVOR A LA PUENTE
1. CSB – RF en FC, con su amplitud modulada por 9960Hz + 1020Hz + VOZ
2. SB1 Banda Lateral 1 – RF en FC, con su amplitud modulada por una onda sinusoidal de 30Hz rectificada. Los lobulos alternados invierten la fase de la RF. (SENO)
3. SB2 Banda Lateral 2 – Igual a SB1, pero con diferencia de 90 grados de fase de los 30Hz. (COSENO)
4. Las bandas laterales se mezclan con la portadora en el puente, formando una portadora modulada.
![Page 31: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/31.jpg)
Add ground check and duantal/quadrantal error resolution
![Page 32: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/32.jpg)
LECTURA
DIAGRAM DE BLOQUES DEL ARMARIO DEL TRANSMISOR
![Page 33: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/33.jpg)
OBJECTIVOS DE LA LECTURA DEL DIAGRAMA DE BLOQUES DEL ARMARIO TRANSMISOR
• Los componentes fisicos del armario
• La funcion mayor de cada modulo
• El flujo de RF, Audio, y senales de control
![Page 34: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/34.jpg)
VISTA DEL TRANSMISOR CON PUERTA CERRADA
![Page 35: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/35.jpg)
COMPONENTES MAYORES DEL TRANSMISOR
TRANSMISOR 1
TRANSMISOR 2
RMS
![Page 36: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/36.jpg)
MODULOS DISTINTOS DEL TRANSMISOR
![Page 37: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/37.jpg)
![Page 38: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/38.jpg)
AUDIO GENERADORAUDIO GENERADOR
![Page 39: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/39.jpg)
CSB GENERADORCSB GENERADOR
![Page 40: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/40.jpg)
GENERADOR DE BANDA LATERALGENERADOR DE BANDA LATERAL
![Page 41: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/41.jpg)
RMSRMS
![Page 42: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/42.jpg)
MONITOREOMONITOREO
![Page 43: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/43.jpg)
FUENTES DE ALIMENTACIONFUENTES DE ALIMENTACION
![Page 44: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/44.jpg)
GENERADOR DE CSB
Sintentizador genera RF de onda continua
Audio Generador agrega Audio
Portadora Modulada
(CSB) a la antena
![Page 45: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/45.jpg)
GENERADOR DE CSB
LPF elimina armonicas
Acoplador Directional suministra muestras para medidas de Potencia y ROE (VSWR)
RF Monitor detecta muestras y suministra audio al Audio Generador para sacar medidas
![Page 46: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/46.jpg)
Banda Lateral 1 SBO: Onda continua en la frecuencia de la portadora, modulada 100% por una onda sinusoidal de 30Hz rectificada.
Onda sinusoidal de 30Hz + Bifase Seno = Onda sinusoidal rectificada, mezclada con el RF para producir el SBO.
Bifase tambien es utilizado para invertir la fase del RF el el mismo tiempo que esta invertiendo la onda sinusoidal.
![Page 47: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/47.jpg)
Banda Lateral 2 SBO: Onda continua en la frecuencia de la portadora, modulada 100% por una onda coseno de 30Hz rectificada.
Onda coseno de 30Hz + Bifase Seno = Onda coseno rectificada, mezclada con el RF para producir el SBO.
Bifase tambien es utilizado para invertir la fase del RF el el mismo tiempo que esta invertiendo la onda coseno.
![Page 48: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/48.jpg)
Fuentes de Alimentacion
![Page 49: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/49.jpg)
RF recibido por la antena dipolo
RF entra a los dos detectores
Ambos monitores pueden seleccionar cualquier detector
RF Detectado (audio) entra en ambos monitores
![Page 50: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/50.jpg)
RF Detectado (audio) de la carga falsa
La senal Standby
Es analizada por ambos monitores En el Standby, solamente se supervisa los niveles de CSB y SBO.
![Page 51: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/51.jpg)
Sincronizacion de Identificacion del DME
![Page 52: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/52.jpg)
LECTURA
OPERACION DEL PMDT
![Page 53: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/53.jpg)
Objectivos de la Lectura de Operacion del PMDT
• Como accesar el PMDT• Organizacion de la pantalla del PMDT• Los iconos Print y Copy• Manejando la Memoria
![Page 54: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/54.jpg)
SEC3
THREE
Hacer Doble-click
en el icono PMDT Utilizar usuario y
Contrasena
Por defecto
![Page 55: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/55.jpg)
Cuatro niveles de seguridad:• Level 1, Solo mirar los datos y
configuraciones• Level 2, solo controles basicos (On, Off,
Transfer, Reset)• Level 3, control y configuracion completa• Level 4, igual a level 3 pero agrega la
capacidad de crear y manejar usuarios
![Page 56: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/56.jpg)
Informacion y controles en la Barra Lateral:
• Si hay una alerta de mantenimiento• Si en modo local (tiene que estar en
modo local para hacer cambios)• Estado y conexion de cada transmisor.
Estos botones permiten control.• Estado de cada monitor. Control de
modo Bypass.• Medidas de los parametros principales.• Estado de los DMEs
Barra Lateral – siempre visible si conectado.
![Page 57: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/57.jpg)
Imprime datos en esta pagina a una
impresora conectada al PC.
Copiar datos de esta pagina al “clipboard”.
Estos datos pueden ser pegados a otros
programas (Word Pad, Word, Excel, email, etc.)
![Page 58: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/58.jpg)
Active RAM –
These values are the ones actually used by the VOR
Screen RAM –
These values are the ones displayed on the screen
Battery-operated Backup memory
PC storage device
Printer connected to the PMDT Laptop
APPLY (F7)RESET (F8)
System, PrintSystem, Configuration, Save
System, Configuration, Load
RMS, Config_Backup
RMS, Config_Restore
![Page 59: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/59.jpg)
LECTURE
CSB TRANSMITTER
![Page 60: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/60.jpg)
Objectives of CSB Transmitter Lecture
• The inputs and outputs of the Frequency Synthesizer and CSB Power Amp
• Physical setting and alignment procedures for the Frequency Generator and CSB Power Amp
• Test Points of Frequency Synthesizer and CSB Power Amp
• Jumper configurations of Frequency Synthesizer and CSB Power Amp
• Signal generation and flow of the CSB
![Page 61: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/61.jpg)
![Page 62: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/62.jpg)
1150-610
R81
1A4/A20
CARRIER FREQ.10 mW (TYP.)
J8
TP4
TP5
GND
TP1
TP2
TP3
Table 3‑9. Synthesizer CCA (1A4, 1A20) Controls and Indicators
TP1 Lower Sideband Quadrature Signal. When Sidebands 1 and 2 (1A4, 1A21) are in phase and equal amplitude this signal is a triangular waveform.
TP2 Upper Sideband Quadrature Signal. When Sidebands 3 and 4 (1A5, 1A22) are in phase and equal amplitude this signal is a triangular waveform.
TP3 Carrier Phase Error Voltage
TP4 Carrier Phase Control Voltage
TP5 DVOR Sideband Manual Phase Control Voltage
TP6 This test point is available for scope or voltmeter groundCarrier sample
for test purposes
![Page 63: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/63.jpg)
Pressing this button causes a window to appear with the proper dip switch settings to select the frequency in the window.
![Page 64: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/64.jpg)
Dip switch settings for frequency selection
![Page 65: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/65.jpg)
Percent modulation leveling
Power out leveling AND VSWR protection is accomplished by the Audio Generator using the forward and reverse power feedback from the RF Monitor
When the percent modulation is programmed to be more than 43%, supply voltage is increased to 48V
Overtemp protection – thermistor mounted on Q5, Q6
![Page 66: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/66.jpg)
Low-Pass Filter Assembly and Directional Coupler
The LPA Filters out harmonics
Reflected port to measure VSWR
Forward port to measure transmitted power
Feedback for phase and frequency lock
Carrier sample for test point
![Page 67: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/67.jpg)
LECTURE
AUDIO GENERATOR
![Page 68: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/68.jpg)
Objectives of Audio Generator Lecture
• The inputs and outputs of the Audio Generator
![Page 69: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/69.jpg)
Componentes de la Señal Compuesta de Audio:
•9960 Hz (30 %)
•Ident (8%) durante el tiempo que se envia la identificación
•Voz (30%) si es seleccionado y hay una entrada
•Componente DC que es proporcional a la potencia de la portadora
Salida Compuesta del Audio Generador
![Page 70: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/70.jpg)
Salidas de Audio del Audio Generador
•Onda sinusoidal de 30 Hz
•Esa onda sera rectificada dentro del Generador de Banda Lateral.
•Banda Lateral 1 y 2 tienen 90 grados de diferencia de fase.
![Page 71: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/71.jpg)
Salidas de bifase del Audio Generador
•Onda cuadrada
•Cada vez que la banda lateral llega a cero, la bifase cambia de nivel
•La bifase es utilizada en el Generador de Banda Lateral para rectificar la onda sinusoidal de 30Hz y para invertir el RF durante la porcion negativa de la onda de 30Hz.
![Page 72: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/72.jpg)
Niveles de Fase de Banda Lateral – nivel DC fijado por el operador del PMDT, para ajustar la fase de la banda lateral a la portadora.
Salidas del Audio Generador de Fasor de Bandal Lateral
![Page 73: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/73.jpg)
Comunicacion Serial entre Audio Generador y el RMS
Datos al RMS para el uso del PMDT – medidas de audio y voltajes analogicas desde el RF Monitor
Señales analogicas y de audio desde el RF Monitor.
Voz desde un sistema automatizado (ejemplo ATIS) o desde un microfono
![Page 74: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/74.jpg)
LECTURA
GENERACION DE LAS BANDAS LATERALES
![Page 75: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/75.jpg)
Objectivos de la Lectura de Generacion de Bandas Laterales
• Entradas y salidas del Generador de Banda Lateral• Procedimientos de Ajuste en Campo del Generador
de Banda Lateral• Funcion de los Aisladores
![Page 76: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/76.jpg)
Sideband 1
RF onda continua en la frecuencia de la portadora
![Page 77: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/77.jpg)
Sideband 2
RF onda continua en la frecuencia de la portadora
![Page 78: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/78.jpg)
Sideband 1
Sideband 2
![Page 79: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/79.jpg)
Puntos de Prueba del Generador de Banda Lateral
Table 3‑10. Generador de Banda Lateral (1A5, 1A21) Indicadores y Controles
TP1 Dynamic Phase Control Voltage – Forma de Onda para compensar por la distorcion de fase causado por la modulacion en Banda Lateral 1.
TP2 Sideband Manual Phase Control Voltage – Voltaje DC definido por el operador en el ajuste de fase de la Banda Lateral 1 a Portadora
TP3 Mean Phase Control Voltage. Nivel DC que compensa por la distorcion de fase causado por cambios de temperatura en Banda Lateral 1.
TP4 Mean Phase Error Voltage – Voltaje que representa el error de fase de la banda lateral 1. Ese valor debe de ser muy cerca de cero.
TP5 La salida de la banda lateral 1 detectada. Una onda sinusoidal rectificada.
![Page 80: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/80.jpg)
Table 3‑10. Sideband Generator (1A5, 1A21) Controls and Indicators
TP6 La salida de la banda lateral 2 detectada. Una onda sinusoidal rectificada.
TP7 Mean Phase Error Voltage – Voltaje que representa el error de fase de la banda lateral 2. Ese valor debe de ser muy cerca de cero.
TP8 Mean Phase Control Voltage. Nivel DC que compensa por la distorcion de fase causado por cambios de temperatura en Banda Lateral 2.
TP9 Sideband Manual Phase Control Voltage – Voltaje DC definido por el operador en el ajuste de fase de la Banda Lateral 2 a Portadora
TP10 Dynamic Phase Control Voltage – Forma de Onda para compensar por la distorcion de fase causado por la modulacion en Banda Lateral 2.
Puntos de Prueba del Generador de Banda Lateral
![Page 81: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/81.jpg)
TP1 (TP10)Cambio suave
No ruido en la parte redondada (no oscilaciones)
Generador de Banda Lateral TP1 y TP10
![Page 82: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/82.jpg)
Los aisladores son utilizados para acoplar la energia reflejada a un circuito detector, para supervisar la ROE (VSWR) de las puertas de banda lateral del puente coaxial
Isolators
![Page 83: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/83.jpg)
LECTURA
RF MONITOR
![Page 84: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/84.jpg)
Objectivos de la Lectura de RF Monitor
• Las entradas y salidas del RF Monitor• Los Puntos de Prueba del RF Monitor• Los puntos de ajuste del RF Monitor
![Page 85: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/85.jpg)
Entradas y salidas del RF Monitor
Cada entrada es de RF
TX 1 Potencia Directa
TX 1 Potencia Reflejada
Cada salida es audio, suministrado al Audio Generator
SB1 Potencia Reflejada
SB2 Potencia Reflejada
Cada salida de audio aparece en un punto de prueba.
El RF Monitor contiene la carga fantasma para el Transmisor Standby
La Potencia Directa de las bandas laterales no son detectadas en el RF Monitor
![Page 86: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/86.jpg)
Ajustes del RF Monitor
Ajustes
Todos los ajustes son para calibrar el las lecturas en el PMDT y igualarlos con un wattmetro externo.
TX 1 y TX2 Potencia Directa y Reflejada
Bandas Lateral 1 y 2 Reflejada
Note: La medida de la potencia directa de cada banda lateral es ajustado utilizando R100 en el Generador de Banda Lateral.
![Page 87: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/87.jpg)
LECTURA
MONITORES
![Page 88: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/88.jpg)
Objectivos de la Lectura Monitores
• Las entradas y salidas del Monitor• Principios de como se analiza la señal compuesta
![Page 89: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/89.jpg)
Antena Monitora
La antena monitora es una antena Dipolo montada en una de las radiales principales (0, 90, 180, or 270). La opcion de Auto Ground Check pone una antena en cada una de 8 o 16 radiales.
![Page 90: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/90.jpg)
Detector 1
Detector 2
Generador de Prueba
Standby Compuesto
![Page 91: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/91.jpg)
Field Det 1
Field Det 2
Test Gen
Composite (TP5)MUX
30Hz Filter Peak Detectpr
Zero Crossing Detectpr
% Mod 30Hz AM
Square Wave
30Hz AM freq, Azimuth
9960 Hz Filter Peak Detectpr
Zero Crossing Detectpr
% Mod 9960Hz AM
Square Wave
9600Hz freq
FM Discriminator Peak Detectpr
Zero Crossing Detectpr
Dev. Ratio FM
Square Wave
30Hz FM freq, Azimuth
300 – 3KHz Filter
1020 Notch FL
1020Hz Filter
% Mod VoicePeak Detectpr
% Mod Ident
Freq Ident
Diagrama de Bloques Simplificado de la Tarjeta Monitor
![Page 92: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/92.jpg)
LECTURA
DETECTOR DE CAMPO
![Page 93: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/93.jpg)
Detecta RF de la antena de monitor de Campo, lo convierte en audio para ser analizado por el monitor.
Lectura Detector de Campo
![Page 94: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/94.jpg)
LECTURE
REMOTE MAINTENANCE SYSTEM (RMS)
![Page 95: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/95.jpg)
CPU CCA Lecture
• The main function of the CPU CCA• The purpose of the Lithium battery
Gathers data for interaction with PMDT and RCSU software.
Communicates with other RMS modules through the backplane.
The EEPROM is actually a battery-operated RAM.
• Retains its memory as long as the battery is good.
• Battery is designed to stay good for 100 years, as long as power remains constantly on.
• It takes more than a month of no power to drain the battery
• If the CPU CCA is removed from the cabinet, remove the battery jumper to conserve charge.
![Page 96: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/96.jpg)
• Allows CPU μP to send and receive info to/from various discrete and analog lines.
Facilities CCA
![Page 97: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/97.jpg)
1 M48V Sys. A BCPS 48 Vdc 2 S48V Sys. B BCPS 48 Vdc 3 M28V Sys. A BCPS 28 Vdc 4 S28V Sys. B BCPS 28 Vdc 5 M12V Sys. A LVPS 12 Vdc 6 S12V Sys. B LVPS 12 Vdc 7 M5V Sys. A LVPS 5 Vdc 8 S5V Sys. B LVPS 5 Vdc 9 M-12V Sys. A LVPS -12 Vdc 10 S-12V Sys. B LVPS -12 Vdc 11 GENLVL Test Generator Level 12 SPARE1 Spare 1 (future use) 13 MBCRET Sys. A BCPS Return (N/C) 14 BARO RET Barometer Sensor Return 15 SBCRET Sys. B BCPS Return (N/C) 16 WIND RET Wind Sensor Return 17 MTXRET Sys. A Transmitter Return 18 TX OUT (OUT) Antenna Status to RSCU 19 STXRET Sys. B Transmitter Return 20 TACH Tachometer 21 MBCOT Sys. A BCPS Overtemp Sta-
tus 22 MBCUPS Sys. A BCPS UPS Status
23 MBCBL Sys. A BCPS Battery Low Status
24 MBCPF Sys. A BCPS Power Fail Status
25 SBCOT Sys. B BCPS Overtemp Sta-tus
26 SBCUPS Sys. B BCPS UPS Status
27 SBCBL Sys. B BCPS Battery Low Status
28 SBCPF Sys. B BCPS Power Fail Status
29 MALM Monitor 1 Alarm 30 MNORM Monitor 1 Normal 31 MBYP Monitor 1 Bypass 32 SALM Monitor 2 Alarm 33 SNORM Monitor 2 Normal 34 SBYP Monitor 2 Bypass 35 MBCCD Sys. A BCPS Charger Dis-
connect (ON/OFF) 36 SBCCD Sys. B BCPS Charger Discon-
nect (ON/OFF) 37 #1 ON Turn-on Sys. A Signal
from RSCU Control Interface CCA
38 #2 ON Turn-on Sys. B Signal from RSCU Control Interface CCA
39 OFF Turn-off On-Air System Signal from RSCU Control Interface CCA
40 TX IND (IN) On-Air Transmitter Indicator Status from Relay 1K1
41 SPARE 8 Spare 8 (future use) 42 Spare 7 Spare 7 (future use) 43 TRANSFER Transfer Status to RSCU
Control Interface CCA 44 SPARE2 Spare 2 (future use)
45 SPARE3 Spare 3 (future use) 46 SPARE4 Spare 4 (future use) 47 SPARE 5 Spare 5 (future use) 48 TIME INTER-
VAL INTO Signal from CPU CCA
49 SPARE 6 Spare 6 (future use) 50 FAN2 (Disabled)
Facilities CCA Inputs and Outputs
![Page 98: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/98.jpg)
Summary – Allows CPU μP to communicate with devices that require serial communication.
•Audio Generator(s)•Monitors•DME(s)•PMDT•External Modem (if used, not required)
Serial Interface CCA
![Page 99: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/99.jpg)
Provides a composite audio signal to apply to the monitors for testing/certification.
It takes several minutes for a signal to form once it is configured.
Test Generator CCA
![Page 100: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/100.jpg)
Two modems on this module:
1. Dedicated line for RCSU
2. Dialup modem for remote PMDT connection
Modem CCA
![Page 101: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/101.jpg)
Optional RSCU Interface
Allows interface between VOR and obsolete 1138 RSCU.
![Page 102: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/102.jpg)
Low Voltage Power Supplies
1150-113
A18POWER PANEL
(PART OF) 1A34POWER SUPPLY (STANDBY)950350-0002
950350-0002POWER SUPPLY (MAIN)
1A33
030398-0002
030757-0001
030749-0001
030363-0002
030757-0001
030398-0002
012616-1003
012617-1003
012743-0001
012743-0001
012743-0001
012618-1003
012689-1001
012620-0001
012619-0002
012101-1001
012617-1003
012616-1003
A1 RF MONITOR ASSEMBLY
SIDEBAND GENERATOR
SYTHESIZER
CSB POWER AMPLIFIER
JACK ASSEMBLY
SYTHESIZER
SIDEBAND GENERATOR
AUDIO GENERATOR
MONITOR
LOW VOLTAGE POWER SUPPLY
LOW VOLTAGE POWER SUPPLY
LOW VOLTAGE POWER SUPPLY
CPU
TEST GENERATOR
FACILITIES
SERIAL INTERFACE
MODEM
MONITOR
AUDIO GENERATOR
A2
1A7
1A8
1A9
1A10
SPARE 1SPARE 2
1A11
1A12
1A13
1A14
1A15
1A16
1A24
1A23
1A21
1A20
1A19
1A38
1A4
1A3
1A5
CCA DISPLAY A1A1 & A1A2
SYSTEM
NORM
AC INPUTPOWER
DC INPUTPOWER
BA
OFF
ON
ON
OFF
AUDIO
1150 VORSYSTEM A
OFF
ON
INTERNATIONAL,INC.SYSTEMSAIRPORT
CABINET DOOR REMOVED FOR CLARITY
ON
OFF
MIC
NORM ALARM BYPASS
030364-0001
OR 030363-0003
OR 030363-0003030363-0002
SIDEBAND GENERATOR1A6 030398-0002
SIDEBAND GENERATOR030398-0002
1A221A14 supplies the RMS
1A15 supplies Transmitter 1
1A16 supplies Transmitter 2
![Page 103: 4.2) CVOR Overheads Selex Spanish.ppt](https://reader037.vdocuments.co/reader037/viewer/2022102421/55cf9e06550346d033b05943/html5/thumbnails/103.jpg)
•6.4.3 Cabinet Backplane Connector Adjustment. Use if a replacement module in the RMS does not quite fit into the slot.
•6.4.4 Replacing CPU (1A13) CCA. Use this procedure when replacing a CPU CCA. It outlines the procedures for loading the alignment and configuration data into the new CPU.
•6.4.5 Update of CVOR Software. This should not be attempted except at the instruction of the factory. New software may not be compatible with old hardware.
•6.4.8 Changing the CPU CCA (1A13) Lithium Battery. If the battery fails during Annual Preventive Maintenance (or at any other time), follow this procedure to replace it. This will keep the data intact.
•9.7.1 Strapping Battery Charger Power Subsystem (BCPS) for 240 VAC. On recently sold systems, the BCPS does not need to be strapped.
•9.7.4 Checking the Battery Charger Power Subsystem for 43 or 48 Volts. Use this procedure any time the Main Voltage needs to be checked. Especially check it after the BCPS is replaced, or after a commercial power surge.
Procedures not covered during labs