CALCULO POTENCIA INSTALADA, MAXIMA DEMANDA Y FACTOR DE SIMULTANEIDAD
VIVIENDA DE TRES PISOS
AREA DEL TERRENO 108.00 M2
AREA CONSTRUIDO POR PISO 151.58 M2
AREA LIBRE M2
1. POTENCIA INSTALADA
ALUMBRADO POR AREA DE PISO M2 25 W / M2 (Codig. Elect)
PRIMER PISO 67.15 25 W / M2 1,678.75 W
SEGUNDO PISO 63.47 25 W / M2 1,586.75 W
TERCER PISO 20.96 25 W / M2 524.00 W
ALUMBRADO AREA LIBRE 5 W / M2 (Codig. Elect)
(Area terreno - area const. Primer Piso) 40.85 5 W / M2 204.25 W
TOTAL 3,469.75 W
CARGA MOVIL TOMACORRIENTES
Según NTP- varian de 2000W a 5000 W asumir 4,000.00 W
ELECTROBOMBA 1 HP 735.00 W
CALENTADOR 100 lts 1,200.00 W
POTENCIA INSTALADA TOTAL 9,404.75 W
2. MAXIMA DEMANDA
ALUMBRADO HASTA 2000 W 100 % Cod. Elect 2,000.00 W
LOS SIGUIENTES 118,000 W 35 % ( 3,564.50 -2,0 (1,564.50*0.3 547.575 W
Se resta de 3,564.50 W (carga total de alumbrado y tomacorrientes = 2000 W)
Quedan: 3,564.50 W 2000 W 1,564.50 W AL 35 %
CARGA MOVIL TOMACORRIENTES asumido 4,000.00 2,000.00 W
Se toma el 50 % de la carga movil 4000 W al 50 %
ELECTROBOMBA 1 HP 735 W al 100 % 735.00 W
CALENTADOR 100 W 1200 W 75% 900.00 W
MAXIMA DEMANDA 6,182.58 W
3. FACTOR DE SIMULTANEIDAD
Factor entre Maxima Demanda y Potencia Instalada MD / PI 0.66
DISEÑO DE CONDUCTORES ELECTRICOSI = Dem/(0.80 x 220) I = I X FSEG
176
CIRCUITO PUNTOS WATT/PTO DEMANDA CORRIENTE INTENSIDAD FACT SEG AMPERIOS COD. ELECT
CIRCUITO DE ALUMBRADO
CIRCUITO C-1 5 80 400 220 0.8 2.27 1.25 2.84 2.5 mm
CIRCUITO C-2 9 80 720 220 0.8 4.09 1.25 5.11 2.5 mm
CIRCUITO C-3 3 80 240 220 0.8 4.09 1.25 5.11 2.5 mm
CIRCUITO DE TOMACORRIENTES
CIRCUITO C-4 12 150 1800 220 0.8 10.23 1.25 5.78 2.5 mm
CIRCUITO C-5 14 150 2100 220 0.8 11.93 1.25 6.91 2.5 mm
CIRCUITO C-6 3 150 450 220 0.8 1.25 1.25 1.56 2.5 mm
CIRCUITO ELECTROBOMBA
POTENCIA HP 3 375 1125 220 0.8 6.39 1.25 7.99 2.5 mm
CALENTADOR 3 1200 900 220 0.8 5.11 1.25 6.39 2.5 mm
ALIMENTADOR 1 6182 6182 220 0.8 35.13 1.25 43.91 16.00 mm **
CAIDA DE TENSIONFORMULA ρ= 1/0.0175
Δ v = 2 *I *L / ρ * S
CALCULO DE CAIDA DE TENSION I (AMP) SECCION LONGITUD POTENCIA ρ COBRE CAIDA TENSION CAIDA MAX.
CIRCUITO DE ALUMBRADO 3%(220 V)
CIRCUITO C-1 2.84 2.5 50 1840 57.143 1.99 6.6
CIRCUITO C-2 5.11 2.5 65.28 1680 57.143 4.67 6.6
CIRCUITO C-3 5.11 2.5 7.67 1680 57.143 0.55 6.6CIRCUITO DE TOMACORRIENTES
CIRCUITO C-4 5.78 2.5 40 3300 57.143 3.24 6.6
CIRCUITO C-5 6.91 2.5 65 3750 57.143 6.29 6.6CIRCUITO C-6 1.56 2.5 8 3750 57.143 0.17 6.6 ELECTROBOMBA POTENCIA HP 7.99 2.5 9 375 57.143 1.01 6.6
CALENTADOR 6.39 2.5 6 900 57.143 0.54 6.6
cos Ø
ALIMENTADOR 43.91 16 18.2 6182 57.143 1.75 6.6