schenck fip 401
DESCRIPTION
Descripcion FIP 401TRANSCRIPT
-
INTECONT PLUS For Measuring Systems
% Compact weighingelectronics for continuousmeasuring systems
% Comprehensive basicfunctionality with applicationspecific features
% Enhanced operatingreliability throughdiagnostics and self-testingfunctions
% Integrated display andcontrol panel
% High operating convenience,automatic calibrationprograms
% Serial interfaces; protocolsvia 3964(R) or MODBUS
Application
The INTECONT PLUS WeighingElectronics is specially designed forcontinuous weighing tasks in continuousproduction processes. It is the rightsolution whenever continuous processesrequire material flows to be measured andacquired with high accuracy with the useof
% Belt weighers (MULTIBELT),
% Solids flow meters (MULTISTREAM),
% Coriolis mass flow meters(MULTICOR).
This also covers special applications, e.g.legal-for-trade weighing or use in thehazardous area.The INTECONT PLUS WeighingElectronics is primarily designed forapplications with a need for convenientand elaborate display, control andmonitoring capabilities, in addition to basicmeasuring functions. The weighingelectronics ensures repeatability andtransparency of the production process.
Equipment
The system is supplied as front-of-panelmounting unit or with wall-mounting housingfor local installation. Operation is viaergonomically styled keyboard organized byoperating and service functions. Aluminescent, anti-glare two-line displayensures easy reading of results.For connection to EDP systems, serialinterfaces (3964(R) or MODBUS) areavailable. Commercial printers can beconnected via RS232 interface.
Operating Principle
The INTECONT PLUS functionality variesdepending on type of scale used. However,all variants have the following commonfeatures:
% System accuracy for weighing tasksbetter than 0.05% (DIN EN 61143-1)
% Manual and/or automatic zero setting
% Full feed/dribble feed control foraccurate batching
% High electromagnetic compatibility
% Galvanically isolated outputs
% Fail-safe data memory (EEPROM)
% Integrated diagnostics and self-testingFunctions (SPC)
% Factory presettings for simple andquick commissioning
% Auto calibration (automatic calibrationprograms, self-starting taring)
% Calibration intervals with signal output(intervals selectable at will)
BV-D2061GB
-
% Flow rate pulse (level and pulsewidth set by parameter)
% Status, event, calibration andquantity reports
% Simulation mode for testing andlearning.
Weighing Functions
Depending on mechanical system used,current flow rate is acquired through
% Belt load and belt speed(belt weighers)
% Reactive force (solids flow meters)
% Direct mass flow measurement onthe Coriolis principle (mass flowmeters).
In addition to the comprehensive basicequipment, the following weighingfunctions are available:
% Belt weighers
- Accurate belt speedmeasurement
- Belt influence compensation(BIC)
- Belt run monitoring
- Shifting of weighing to point ofdischarge
- Legal-for-trade variant(upon request)
% Solids Flow Meters
- Adaption to varying measuringchute characteristics
% Coriolis Mass Flow Meters
- Accurate speed and torqueacquisition.
Dimensions (mm)
INTECONT PLUS Wall HousingBelt Weighers, Solids Flow Meters
Bottom View
INTECONT PLUS Wall Housing Coriolis Mass Flow Meters
Panel cut-out282 + 0,5 x 88 + 0,5
INTECONT PLUS for Front-of-Panel Mounting
-
INTECONT PLUS, FIP 401
Technical Data
Display Clear text fluorescent display,2 lines with 20 digits each,6 mm character height
Power supply 24 VDC +30% / -20%Consumption 20 VA
Ambient conditions Operating temperature -40 to 45CHumidity Class F (DIN 40040)EMC (OIML, IEC 801, EN 45501)Spark protection(EN 55011, VDE 871-B)conform to CE regulations
Protection Front-of-panel mounting housingFront protected to IP 65
Inputs Speed (RPM) input(NAMUR level 0.04 - 2500 Hz)Load cell input(R min 80 O, up to 500 m cable)Release contact (24 V, 5 mA)Measurement (Start/Stop 24 V / 5 mA)
Outputs 2 limit values(230 V 8 A ohm./ 1 A induct.) Faults(230 V 8 A ohm./1 A induct.) Pulseoutput(totalizing counter 24 V/0,1A,max. 10 Hz)Analog output(flow rate 0/4 ... 20 mA, 500 O load)Prefeeder contact(Start/Stop, 230 V, 8 A ohm./1 A induct.)Batching(full/dribble feed, 230 V, 8 A ohm./1 A induct.)Control unit contact(Start/Stop, 230 V, 8 A ohm./1 A induct.)
Interfaces Printer RS 2323964(R) interface module (RS422)MODBUS interface module (RS422or RS485)
Options - Technical Datas
Wall housing for beltweighers, solids flowmeters
Wall housing IP 65 (Nema 4)Power supply 120 ... 230 V /24 V
380 mm x 300 x 263 mm
Wall housing for Coriolismass flow meters withcontrol unit and powerswitch
Wall housing IP 55 (Nema 4)Power supply 120 or 230 V /24 VControl unit and power switch380 mm x 300 mm x 236 mm
Power supply, 120 .. 230 V 24 V, 1 A
Analog display 0 - 100%, panel-mounting unit4 - 20 mA, 96mm x 24 mm
Pulse counter,non-resettable
6-digit, non-resettable52 mm x 28 mm
Pulse counter,resettable
6-digit, resettable in manual52 mm x 28 mm
Event printer 9-dot matrix printer with serialinterface RS 232 (V 24) andsystem cable
S5 interface protocolvia 3964(R)
FSP 0010 - program modulefor Siemens S5 (110U /115U /135U) for serialinterfacingData are made available in data module.User prerequisite: CP524 or equivalent
S5 interface protocolvia MODBUS
FSP 0011 - program modulefor Siemens S5 (115U / 135U)for serial interfacingData are made available in data module.User prerequisite: CP524 or equivalent
Special scale/weighingelectronicsinterconnecting cable
Length to be specified in yourorder(as standard, we supply 20 m)
-
INTECONT PLUS Variants
INTECONT PLUS - FIP 401With 3964(R) or MODBUS protocol, 24 VDCsuitable for belt weighers, solids flow meters andCoriolis mass flow meters
INTECONT PLUS FIP 401eWith 3964(R) protocol, legal-for-trade,suitable for belt weighers and Coriolis mass flow meters
Options
Wall housing with power supply 120 V ... 230 Vfor belt weighers and solids flow meters
Wall housing with power supply 120 V ... 230 V, control unitand power switch, for Coriolis mass flow meters
Power supply, 120 V (for plug socket)
Power supply, 230 V (for plug socket)
Power supply, 120 ... 230 V (control cubicle)
Analog display
Pulse counter, non-resettable
Pulse counter, resettable
Event printer
S5 interface module via 3964(R)
S5 interface module via MODBUS
Special scale/weighing electronics interconnecting cable
BV
-D20
61G
B X
BS
05.
1002
. We
rese
rve
the
right
to d
isco
ntin
ue o
r ch
ange
spe
cific
atio
ns a
t any
tim
e w
ithou
t not
ice
or o
blig
atio
n.
Measuring and Process SystemsSCHENCK PROCESS GmbHD-64273 DarmstadtPhone: +49 (0) 61 51-32 10 28Fax: +49 (0) 61 51-32 11 72E-Mail: [email protected]
wwww.schenck-process.net