  • INTECONT PLUS For Measuring Systems

    % Compact weighingelectronics for continuousmeasuring systems

    % Comprehensive basicfunctionality with applicationspecific features

    % Enhanced operatingreliability throughdiagnostics and self-testingfunctions

    % Integrated display andcontrol panel

    % High operating convenience,automatic calibrationprograms

    % Serial interfaces; protocolsvia 3964(R) or MODBUS

    Application

    The INTECONT PLUS WeighingElectronics is specially designed forcontinuous weighing tasks in continuousproduction processes. It is the rightsolution whenever continuous processesrequire material flows to be measured andacquired with high accuracy with the useof

    % Belt weighers (MULTIBELT),

    % Solids flow meters (MULTISTREAM),

    % Coriolis mass flow meters(MULTICOR).

    This also covers special applications, e.g.legal-for-trade weighing or use in thehazardous area.The INTECONT PLUS WeighingElectronics is primarily designed forapplications with a need for convenientand elaborate display, control andmonitoring capabilities, in addition to basicmeasuring functions. The weighingelectronics ensures repeatability andtransparency of the production process.

    Equipment

    The system is supplied as front-of-panelmounting unit or with wall-mounting housingfor local installation. Operation is viaergonomically styled keyboard organized byoperating and service functions. Aluminescent, anti-glare two-line displayensures easy reading of results.For connection to EDP systems, serialinterfaces (3964(R) or MODBUS) areavailable. Commercial printers can beconnected via RS232 interface.

    Operating Principle

    The INTECONT PLUS functionality variesdepending on type of scale used. However,all variants have the following commonfeatures:

    % System accuracy for weighing tasksbetter than 0.05% (DIN EN 61143-1)

    % Manual and/or automatic zero setting

    % Full feed/dribble feed control foraccurate batching

    % High electromagnetic compatibility

    % Galvanically isolated outputs

    % Fail-safe data memory (EEPROM)

    % Integrated diagnostics and self-testingFunctions (SPC)

    % Factory presettings for simple andquick commissioning

    % Auto calibration (automatic calibrationprograms, self-starting taring)

    % Calibration intervals with signal output(intervals selectable at will)

    BV-D2061GB

  • % Flow rate pulse (level and pulsewidth set by parameter)

    % Status, event, calibration andquantity reports

    % Simulation mode for testing andlearning.

    Weighing Functions

    Depending on mechanical system used,current flow rate is acquired through

    % Belt load and belt speed(belt weighers)

    % Reactive force (solids flow meters)

    % Direct mass flow measurement onthe Coriolis principle (mass flowmeters).

    In addition to the comprehensive basicequipment, the following weighingfunctions are available:

    % Belt weighers

    - Accurate belt speedmeasurement

    - Belt influence compensation(BIC)

    - Belt run monitoring

    - Shifting of weighing to point ofdischarge

    - Legal-for-trade variant(upon request)

    % Solids Flow Meters

    - Adaption to varying measuringchute characteristics

    % Coriolis Mass Flow Meters

    - Accurate speed and torqueacquisition.

    Dimensions (mm)

    INTECONT PLUS Wall HousingBelt Weighers, Solids Flow Meters

    Bottom View

    INTECONT PLUS Wall Housing Coriolis Mass Flow Meters

    Panel cut-out282 + 0,5 x 88 + 0,5

    INTECONT PLUS for Front-of-Panel Mounting

  • INTECONT PLUS, FIP 401

    Technical Data

    Display Clear text fluorescent display,2 lines with 20 digits each,6 mm character height

    Power supply 24 VDC +30% / -20%Consumption 20 VA

    Ambient conditions Operating temperature -40 to 45CHumidity Class F (DIN 40040)EMC (OIML, IEC 801, EN 45501)Spark protection(EN 55011, VDE 871-B)conform to CE regulations

    Protection Front-of-panel mounting housingFront protected to IP 65

    Inputs Speed (RPM) input(NAMUR level 0.04 - 2500 Hz)Load cell input(R min 80 O, up to 500 m cable)Release contact (24 V, 5 mA)Measurement (Start/Stop 24 V / 5 mA)

    Outputs 2 limit values(230 V 8 A ohm./ 1 A induct.) Faults(230 V 8 A ohm./1 A induct.) Pulseoutput(totalizing counter 24 V/0,1A,max. 10 Hz)Analog output(flow rate 0/4 ... 20 mA, 500 O load)Prefeeder contact(Start/Stop, 230 V, 8 A ohm./1 A induct.)Batching(full/dribble feed, 230 V, 8 A ohm./1 A induct.)Control unit contact(Start/Stop, 230 V, 8 A ohm./1 A induct.)

    Interfaces Printer RS 2323964(R) interface module (RS422)MODBUS interface module (RS422or RS485)

    Options - Technical Datas

    Wall housing for beltweighers, solids flowmeters

    Wall housing IP 65 (Nema 4)Power supply 120 ... 230 V /24 V

    380 mm x 300 x 263 mm

    Wall housing for Coriolismass flow meters withcontrol unit and powerswitch

    Wall housing IP 55 (Nema 4)Power supply 120 or 230 V /24 VControl unit and power switch380 mm x 300 mm x 236 mm

    Power supply, 120 .. 230 V 24 V, 1 A

    Analog display 0 - 100%, panel-mounting unit4 - 20 mA, 96mm x 24 mm

    Pulse counter,non-resettable

    6-digit, non-resettable52 mm x 28 mm

    Pulse counter,resettable

    6-digit, resettable in manual52 mm x 28 mm

    Event printer 9-dot matrix printer with serialinterface RS 232 (V 24) andsystem cable

    S5 interface protocolvia 3964(R)

    FSP 0010 - program modulefor Siemens S5 (110U /115U /135U) for serialinterfacingData are made available in data module.User prerequisite: CP524 or equivalent

    S5 interface protocolvia MODBUS

    FSP 0011 - program modulefor Siemens S5 (115U / 135U)for serial interfacingData are made available in data module.User prerequisite: CP524 or equivalent

    Special scale/weighingelectronicsinterconnecting cable

    Length to be specified in yourorder(as standard, we supply 20 m)

  • INTECONT PLUS Variants

    INTECONT PLUS - FIP 401With 3964(R) or MODBUS protocol, 24 VDCsuitable for belt weighers, solids flow meters andCoriolis mass flow meters

    INTECONT PLUS FIP 401eWith 3964(R) protocol, legal-for-trade,suitable for belt weighers and Coriolis mass flow meters

    Options

    Wall housing with power supply 120 V ... 230 Vfor belt weighers and solids flow meters

    Wall housing with power supply 120 V ... 230 V, control unitand power switch, for Coriolis mass flow meters

    Power supply, 120 V (for plug socket)

    Power supply, 230 V (for plug socket)

    Power supply, 120 ... 230 V (control cubicle)

    Analog display

    Pulse counter, non-resettable

    Pulse counter, resettable

    Event printer

    S5 interface module via 3964(R)

    S5 interface module via MODBUS

    Special scale/weighing electronics interconnecting cable

    BV

    -D20

    61G

    B X

    BS

    05.

    1002

    . We

    rese

    rve

    the

    right

    to d

    isco

    ntin

    ue o

    r ch

    ange

    spe

    cific

    atio

    ns a

    t any

    tim

    e w

    ithou

    t not

    ice

    or o

    blig

    atio

    n.

    Measuring and Process SystemsSCHENCK PROCESS GmbHD-64273 DarmstadtPhone: +49 (0) 61 51-32 10 28Fax: +49 (0) 61 51-32 11 72E-Mail: [email protected]

    wwww.schenck-process.net