    Innovative Solutions for Non IntrusiveInspecting of Insulated Objects

    ing. Mark de WaardProject Manager

    Applus RTD

  • 8/17/2019 RTD Incotest Presentation

    2/27

    Contents

    Introduction Applus RTD

    Non Intrusive Inspection

    Principle of RTD-INCOTEST ®

    Top 5 Applications

    | 2

  • 8/17/2019 RTD Incotest Presentation

    3/27

    Introduction Applus RTD

    RTD was Founded in 1937 in the NetherlandsPart of the Applus Group in 2006Specialized in Non-Destructive Testing (NDT) andInspection Solutions

    | 3

  • 8/17/2019 RTD Incotest Presentation

    4/27

    Introduction Applus RTD

    | 4

  • 8/17/2019 RTD Incotest Presentation

    5/27

    Examine installation parts whenever you want while in-service

    No unnecessary destruction of insulation or other

    Status on interior/exterior of equipment

    Know what is happening before a maintenance shutdown

    | 5

    Non-Intrusive means

  • 8/17/2019 RTD Incotest Presentation

    6/27

    | 6

    Last minutedefects are found

    ExtendeddowntimePlanned downtime

    Early in-serviceinspection

    Downtime is shorter as you know exactlywhere to look without last minute surprises

    Common approach

    The Applus RTD approach

    Minimizing Downtime

  • 8/17/2019 RTD Incotest Presentation

    7/27

  • 8/17/2019 RTD Incotest Presentation

    8/27

    In-Service Spot Check

    Alternative RTD-INCOTEST®

    ? Average Wall Thickness screening in one single areaMapping according to gridOnly global degradation; detection of local corrosion is

    sheer luck

    | 8

  • 8/17/2019 RTD Incotest Presentation

    9/27

    Principle of RTD-INCOTEST ®

    IN sulated COmponent TEST ing,by means of Pulsed Eddy Current (PEC)

    | 9

  • 8/17/2019 RTD Incotest Presentation

    10/27

    Principle of RTD-INCOTEST ®

    Low Alloy Carbon Steel (ferromagnetic)

    Wall Thickness 6-65 mm

    Insulation Thickness

  • 8/17/2019 RTD Incotest Presentation

    11/27

    Principle of RTD-INCOTEST ®

    Sensor selection diagram - none, alu & SS sheeting

    0

    10

    20

    30

    40

    50

    60

    70

    0 25 50 75 100 125 150 175 200 225 250 _ _ _ _ MKI Lift-off [mm] _____ MKII

    W a l

    l t h i c k n e s s

    [ m m

    ]

    V1.0-02

    P0.5-1

    P1.5-04

    P0.25-0

    | 11

  • 8/17/2019 RTD Incotest Presentation

    12/27

    Standard probes

    50mm

    Principle of RTD-INCOTEST ®

    | 12

  • 8/17/2019 RTD Incotest Presentation

    13/27

    Principle of RTD-INCOTEST ®

    | 13

    Time

  • 8/17/2019 RTD Incotest Presentation

    14/27

    Principle of RTD-INCOTEST ®

    | 14

  • 8/17/2019 RTD Incotest Presentation

    15/27

    Principle of RTD-INCOTEST ®

    | 15

    InspectionGrid

    AWT [%]

    Eddy CurrentDecay

    Evaluation

    Numbers

  • 8/17/2019 RTD Incotest Presentation

    16/27

    Top 5 Applications

    Sphere Legs

    Piping

    Vessels and Tanks

    Columns

    Sub Sea Applications

    | 16

  • 8/17/2019 RTD Incotest Presentation

    17/27

    Top 5 Applications – Sphere Legs

    | 17

  • 8/17/2019 RTD Incotest Presentation

    18/27

    Top 5 Applications – Sphere Legs

    | 18

  • 8/17/2019 RTD Incotest Presentation

    19/27

    Top 5 Applications – Piping

    | 19

  • 8/17/2019 RTD Incotest Presentation

    20/27

    Top 5 Applications – Vessels and Tanks

    | 20

  • 8/17/2019 RTD Incotest Presentation

    21/27

    Top 5 Applications – Columns

    | 21

  • 8/17/2019 RTD Incotest Presentation

    22/27

    Top 5 Applications – Sub Sea

    | 22

    Off-shore = On-shore for RTD-INCOTEST ®

  • 8/17/2019 RTD Incotest Presentation

    23/27

    Top 5 Applications – Sub Sea

    | 23

  • 8/17/2019 RTD Incotest Presentation

    24/27

    Conventional

    Down timeScaffolding

    Insulation RemovalSurface preperationInspection

    Apply Insulation

    | 24

    RTD-INCOTEST ®

    On streamRope Access orExtension ToolDirectly on Insulation

    Why RTD-INCOTEST ®

  • 8/17/2019 RTD Incotest Presentation

    25/27

    Screening and follow-up

    | 25

    False Call

    Severe Corrosion !

  • 8/17/2019 RTD Incotest Presentation

    26/27

    Reporting RTD-INCOTEST ®

    | 26

  • 8/17/2019 RTD Incotest Presentation

    27/27

    Corrosion Detection

    Screening Tool

    No Direct Surface Contact Needed

    No Surface Preparation Needed

    On-Stream

    Saves Time, Costs * and Risk