medhouses building quality and installations - costa blanca

20
Calidad Constructiva Medhouses Medhouse Building Quality ¿Qué nos hace distintos? What makes us different?

Upload: armando-macia

Post on 13-Apr-2017

131 views

Category:

Real Estate


2 download

TRANSCRIPT

Page 1: Medhouses Building Quality and Installations - Costa Blanca

Calidad Constructiva Medhouses Medhouse Building Quality

¿Qué nos hace distintos?

What makes us different?

Page 2: Medhouses Building Quality and Installations - Costa Blanca

Obtuvimos un certificado energético B con calificación 39 KW/ m2 al año lo que supone una de las mejores calificaciones en la provincia gracias a nuestras instalaciones de ahorro energético y calidad constructiva basado en sistemas sostenibles.

We have received a B energy certification with a result of 39 KW /m2 per year which is one of the best energy certifications on the Costa Blanca which are based on energy saving installationis and sustainable building systems.

ENERGY CERTIFICATION

Page 3: Medhouses Building Quality and Installations - Costa Blanca

I. Cerramientos I. Walls, Ceilings and Floors

Page 4: Medhouses Building Quality and Installations - Costa Blanca

Muro Estándar / Standard Wall Muro Medhouses / Medhouses Wall

interior exterior

Bri

ck/

Lad

rillo

Exp

and

ed

Po

listy

ren

e in

sula

tio

n/

Po

liesp

an

Exp

an

did

o

Bri

ck/

Lad

rillo

interior exterior

Bri

ck/

Lad

rillo

Co

mp

ress

ed

Po

lyst

yre

ne

/ P

olie

spa

n E

xtru

ído

Bri

ck/

Lad

rillo

12

cm

Aprox. 24cm Aprox. 33cm

Page 5: Medhouses Building Quality and Installations - Costa Blanca

El poliestireno extruido comparte muchas características con el poliestireno expandido, pues su composición química es idéntica: aproximadamente un 95% de poliestireno y un 5% de gas. La diferencia radica únicamente en el proceso de conformación, pero es una diferencia crucial, ya que el extrusionado produce una estructura de burbuja cerrada, lo que convierte al poliestireno extrusionado en el único aislante térmico de una conductividad mínima térmica ademas de ser capaz de mojarse sin perder sus propiedades.

Compressed Polistyrene has many common features with expanded polistyrene as its chemical composition is basically the same (95% polistyrene and 5% gas). The difference lies in its formation, but this difference is crucial as this compression produces a structure of closed bubbles, that makes this material the only thermal insulator with a minimal thermal conductivity and capable of maintaning all its properties even when in contact with water.

Standard Poliestireno Expandido Expanded Polistyrene Medhouses

Poliestireno Extruído Compressed Polistyrene

Page 6: Medhouses Building Quality and Installations - Costa Blanca

Corte sección de un techo plano de Medhouses Cross section of a flat Medhouses ceiling/ roof

En Medhouses añadimos entre 3-5 cm más de aislamiento en los techos de nuestras viviendas. El mínimo son 3 cm de aislamiento en techos planos y no hay mínimo en techos de teja. En Medhouses ponemos entre 5 y 8 cm de aislamiento. At Medhouses we add between 3-5 cm more of insulation to our ceilings. The minimum required in flat rooves is 3 cm and nothing for slanted roovs with roof tiles. At Medhouses we install insulation of between 5 to 8 cm.

Page 7: Medhouses Building Quality and Installations - Costa Blanca

Suelo Estándar / Standard Floors Suelo Medhouses / Medhouses Floor

base hormigón / concrete base

base hormigón / concrete base

aislamiento / insulation

azulejo / tiled floor azulejo / tiled floor

5cm

Page 8: Medhouses Building Quality and Installations - Costa Blanca

II. VENTANAS II. WINDOWS AND DOUBLE GLAZING

Page 9: Medhouses Building Quality and Installations - Costa Blanca

Rotura Puente Térmico – Thermal Break Windows

Page 10: Medhouses Building Quality and Installations - Costa Blanca

Ventanas estándar / Standard Windows Ventanas Medhouses / Medhouses Windows Rotura de Puente Térmico / Thermal Break

Interior Exterior Interior Exterior

Calor/ Heat

Condesación Condensation

*Imagen orientativa / Image for descriptive purposes

Calor/ Heat

Condesación Condensation

Page 11: Medhouses Building Quality and Installations - Costa Blanca

III. INSTALACIONES III. INSTALLATIONS

Page 12: Medhouses Building Quality and Installations - Costa Blanca

ARISTON NUOS – HEAT PUMP BOILER

www.nuosariston.es

• Hasta un 70% de ahorro • 25% Uso energía de la red, 75% auto generado • Sencillo y sin mantenimiento • 100% reciclable • ACS 24 horas al día • Función auto-limpieza

• Up to 70% savings • 25% mains electricity and75% self generated • Simple and 0 maintenance • 100% recycable • Hot water 24 hours a day • Auto cleaning functions

*Imagen orientativa / Image for descriptive purposes

Page 13: Medhouses Building Quality and Installations - Costa Blanca

Uso de plantas autóctonas de bajo consumo de agua (Xerojardinería) Use of indigenous plants with low water consumption (Xeroscaping)

•Modo más sostenible de riego • Sencillo sin mantenimiento • Coste 0 • Riego por goteo, máxima eficacia • Xylojardinería: Bajo consumo de agua

•Sustainable irrigation • Simple with zero maintenance • Zero costs • Drop irrigation, maximum efficiency • Plants with low water requirements

*Imagen orientativa / Image for descriptive purposes

Page 14: Medhouses Building Quality and Installations - Costa Blanca

*Imagen orientativa / Image for descriptive purposes

VENTILACIÓN CRUZADA – CROSS VENTILLATION

• Ventilación de aire nuevo de manera continuada • Reduce necesidad de aire acondicionado • Permite aire limpio y reduce infecciones por aire estancado. • Coste Cero

• Constant flow of fresh air • Reduces the need for air conditioning during certain times • Allows for clean air to flow through the house avoiding infections from stagnant air. • Zero cost

Page 15: Medhouses Building Quality and Installations - Costa Blanca

IV. FONTANERÍA IV. PLUMBING

Page 16: Medhouses Building Quality and Installations - Costa Blanca

Doble pulsador en aseos Double flush system in toilets

Con este sistema hay un ahorro considerable de agua. With this system there is a considerable saving of water

Page 17: Medhouses Building Quality and Installations - Costa Blanca

Grifos con sistemas de ahorro de agua Water saving systems in taps

Grifos con doble posicionamiento para evitar un consumo desproporcionado de agua. Double position taps to avoid waste of water.

Page 18: Medhouses Building Quality and Installations - Costa Blanca

V. Opciones ECO-Plus V. ECO-Plus Options

Page 19: Medhouses Building Quality and Installations - Costa Blanca

•Medidor de consumo • Sistemas Aero-termia (Altherma o similar)

• suelo radiante • aire acondicionado • calefacción

•Generador Eólico •Paneles solares foto voltaicos •Domótica aplicada al ahorro energético •Reciclaje de aguas grises •Caldera Bio-masa • Electrodomésticos AAA+ •LEDs iluminación • Y muchos más…

•Energy consumption gauge • Aero-thermia system (Altherma or similar)

• under floor heating • air conditioning • pool heating • central heating

• Wind generated energy • Solar panels •Smart home technology for saving energy • Grey water recycling • Biomass boiler • Class AAA+ appliances • LED lighting • And many more…

Page 20: Medhouses Building Quality and Installations - Costa Blanca

Para más informacion / For more information Armando Macia [email protected] tel: 630 368 835 www.medhouses.com