gl 80 aa
DESCRIPTION
RefrigeracionTRANSCRIPT
GL80AA.02PRODUCT SPECIFICATION
OPERATION:
Application: L.B.P. Max. Ambient Temp: 43°CRefrigerant: R134a
(1) Max. Steady Discharge Temp: 120°COperation: Capillary (1,2) Max. Peak Discharge Temp: 135°C
Cooling: Static Max. Steady Condensing Temp: 60°C(2) Max. Peak Condensing Temp: 70°C
Max. Winding Temp: 130°C
Max. Impurities: 30 mgMax. Total Compressor Water Content: 100 mg
COMPRESSOR:
Displacement: 7.39 cc Oil Type: EsterBore: 24.29 mm (4) Viscosity: 15 cSt
Stroke: 15.94 mm Suction Muffler: Semi-direct
(3) Net Wt: 9.0 kgCase Size: 2 (h = 175 mm)Oil Charge: 210 cc
ELECTRICAL:
Power Supply: 220 - 240V Motor Type: RSIR / RSCR *Voltage Limits: 187 - 264V
Frequency: 50 Hz Locked Rotor Current: 12.0 / 7.1 A**Phase: 1 ph
Main Winding Resistance at 25°C: 11.7 ΩStart Winding Resistance at 25°C: 18,8 Ω
* With Optional Run Capacitor
** Maximum current / Measured after 4 seconds
For rated performance,
(1) Measured 5cm. from the shell with insulated thermocouples the suction line must be connected to the stub
(2) For transient conditions during 'Pull Down' marked 'AS' on the attached drawing.
(3) Net weight is with oil but without electrics
(4) Measured at 40°C
AE 0218.5 Aug '03 Page 1 Electrolux Compressors reserves the right to change the data without prior notice
h
GL80AA.02PRODUCT SPECIFICATION
ELECTRICAL COMPONENTS:
ZEM Starting Device: PTC- 8100 UH Starting Device: PTC- 3003-x(1) ZEM Starting Device: PTC - 7100D6 UH PTC Resistance: 14 Ω
ZEM PTC Resistance: 14 Ω Alt. UH Starting Device: PTC- 3001-xECC Starting Device: K 100-xx
Run Capacitor: 4.0 µF-x PTC code for different contact versions
-xx Protector short code
PROTECTORS:
PROTECTORS BDG ¾ Electrica ¾Type AE 15 BW x T 0502 / kk
Open °C 125 - 135 °C 125 - 135 °CClose °C 71 - 53 °C 70 - 55 °C
U.T.C 1.95 A 70 °C 2.37 A 70 °CTime Check Current 8.20 A 9.00 A
Max. Current 16.0 A 17.0 ACode (if any) FQ CE
Alt. protectors: AF 15 BW xD6
BDG 'x' Codes: 6 for terminal boards Mod.89,90
8 for terminal board Mod.91
4 for UH protector with 6.3mm fast-on
5 for UH protector with M3.5 screw
Electrica 'kk' Codes: 05 for terminal boards Mod.89,90
07 for terminal board Mod.91
C5 for UH protector with M3.5 screw
C6 for UH protector with 6.3mm fast-on
Protectors with M 3.5 screws can be used on UH electric housings type SP-1454 (with connection board)
and SP-1821 (without connection board).See drawings ELECTRICAL ASSEMBLY (FOR UH) number FTC15;16;17;18.
¾ protectors with 6.3mm fast-on can only be used on UH electric housing type SP-1821 (without connection board).
AE 0218.5 Aug '03 Page 2 Electrolux Compressors reserves the right to change the data without prior notice
GL80AA.02PRODUCT SPECIFICATION
PERFORMANCE: (Graphs are at ASHRAE conditions) 220V 50Hz Without run capacitor
Evaporating Temperature °C -30 -25 -23.3 -20 -15 -10
ASHRAE: Capacity Kcal/h 109 153 170 206 266 337C.o.P. W / W 1.02 1.19 1.25 1.37 1.55 1.73
CECOMAF: Capacity W 104 145 195 252 319C.o.P. W / W 0.84 0.97 1.11 1.26 1.41
Input Power W 124 150 158 175 200 227Current A 1.06 1.12 1.14 1.19 1.27 1.37
AE 0218.5 Aug '03 Page 3 Electrolux Compressors reserves the right to change the data without prior notice
0
50
100
150
200
250
300
350
400
-35 -30 -25 -20 -15 -10 -5Evaporating Temperature (°C)
Capacitykcal/h
0.50
0.70
0.90
1.10
1.30
1.50Amps
40
90
140
190
240InputWatts
0.00
0.20
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
2.00C.o.P.
Test Conditions:Condensing Temp:Liquid Temp:Gas Return Temp:Ambient Temp:
CECOMAF55°C55°C32°C32°C
ASHRAE55°C32°C32°C32°C
PROVISIONAL
GL80AA.02PRODUCT SPECIFICATION
AE 0218.5 Aug '03 Page 4 Electrolux Compressors reserves the right to change the data without prior notice
Appliance,Lights etc.
Circuit Diagram for Mod.90 Terminal Board
Wire Connection
Thermostat
Fast-onconnectors
L
1
N
N
L
MotorProtector
PTCRelay
Run Capacitorwhere applicable
E
S
x = 26mm or 28.5mmy = 9mm or 10.3mmOther sizes available1. Rubber grommet2. Sleeve3. Washer4. Steel pin5. Clip
Appliance,Lights etc.
Circuit Diagram for U.H. Terminal Board
MotorProtector
Wire Connection
Thermostat
PTCRelay
L
1
N
NL
Run Capacitorwhere applicable
Upright
Tubes Down
Electrics Up
Recommended Transport Positions when fitted into
appliances
VARIANT CODE
SERIAL NUMBERBAR CODE
REFRIGERANT
MODEL
LOGO
PRODUCTION DATE CODE
APPROVALS
MANUFACTURER
VERSION CODE
CHECK DIGIT
Compressor Label
ELECTRICAL CHARACTERISTICS
Mounting Accessories
1
y
x
1
453
5th Optional N L
N
EL
Circuit Diagram for ECC Terminal Board Frontal Version
1
MotorProtector
PTC
S
Appliance,Lights etc.
Thermostat
Run Capacitorwhere applicable
x
y
2
B