ejemplos_

4
D-2 Example D.1 W-Shape Tension Member Given: Select an 8 in. W-shape, ASTM A992, to carry a dead load of 30 kips and a live load of 90 kips in tension. The member is 25 ft long. Verify the member strength by both LRFD and ASD with the bolted end connection shown. Verify that the member satisfies the recommended slenderness limit. Solution: Calculate the required tensile strength LRFD ASD P u = 1.2(30 kips) + 1.6(90 kips) = 180 kips P a = 30 kips + 90 kips = 120 kips Try a W821 Material Properties: W821 ASTM A992 F y = 50 ksi F u = 65 ksi Manual Table 2-3 Geometric Properties: W821 A g = 6.16 in. 2 b f = 5.27 in. t f = 0.400 in. d = 8.28 in. r y = 1.26 in. y = 0.831 in. (for WT410.5) Manual Table 1-1 Table 1-8 Check tensile yield limit state using tabulated values LRFD ASD 277 kips > 180 kips o.k. 184 kips > 120 kips o.k. Manual Table 5-1 Check the available tensile rupture strength at the end connection Verify the table assumption that / 0.75 e g A A for this connection

Upload: hansvalerio

Post on 17-May-2017

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ejemplos_

D-2

Example D.1 W-Shape Tension Member

Given:

Select an 8 in. W-shape, ASTM A992, to carry a dead load of 30 kips and a live load of 90 kips in tension. The

member is 25 ft long. Verify the member strength by both LRFD and ASD with the bolted end connection shown.

Verify that the member satisfies the recommended slenderness limit.

Solution:

Calculate the required tensile strength

LRFD ASD

Pu = 1.2(30 kips) + 1.6(90 kips)

= 180 kips

Pa = 30 kips + 90 kips

= 120 kips

Try a W8 21

Material Properties:

W8 21 ASTM A992 Fy = 50 ksi Fu = 65 ksi Manual

Table 2-3

Geometric Properties:

W8 21 Ag = 6.16 in.2 bf = 5.27 in. tf = 0.400 in. d = 8.28 in.

ry = 1.26 in.

y = 0.831 in. (for WT4 10.5)

Manual

Table 1-1

Table 1-8

Check tensile yield limit state using tabulated values

LRFD ASD

277 kips > 180 kips o.k. 184 kips > 120 kips o.k. Manual

Table 5-1

Check the available tensile rupture strength at the end connection

Verify the table assumption that !/ 0.75e g

A A for this connection

Page 2: Ejemplos_

D-3

Calculate U as the larger of the values from Table D3.1 case 2 or case 7

Case 2 – Check as 2WT-shapes

U = "1x

l = "

0.831 in.1

9.00 in.= 0.908

Case 7

bf = 5.27 in. d = 8.28 in. bf < 2/3d

U = 0.85

Use U = 0.908

Calculate An

An = Ag – 4(dh + z in.)tf

= 6.16 in.2 – 4(m in. + z in.)(0.400 in.) = 4.76 in.2

Calculate Ae

Ae = AnU

= 4.76 in.2(0.908) = 4.32 in.2

Ae /Ag = 4.32 in.2 / 6.16 in.2 = 0.701 < 0.75 tabulated values for rupture n.a.

Pn = FuAe = (65 ksi)(4.32 in.2) = 281 kips

Commentary

Fig. C-D3.1

Table D3.1

Case 2

Table D3.1

Case 7

Section D3.2

Section D3.3

Eqn. D3-1

Eqn. D2-2

LRFD ASD

Section D2 #t = 0.75$#tPn = 0.75(281 kips) = 211 kips

211 kips > 180 kips o.k.

%t = 2.00

Pn/%t = (281 kips)/2.00 = 141 kips

141 kips > 120 kips o.k.

LRFD ASD

225 kips > 180 kips o.k. 150 kips > 120 kips o.k. Manual

Table 5-1

TheW8 21 available tensile strength is governed by the tensile rupture limit state at the end

connection.

Check the non-mandatory slenderness limit

& '& '( ( )* +* +, -, -

25.0 ft 12.0 in./ 238 300

1.26 in. ftL r o.k.

Section D1

Page 3: Ejemplos_

D-4

Example D.2 Single-Angle Tension Member

Given:

Verify, by both ASD and LRFD, the strength of an L4 4 ½, ASTM A36, with one line of (4) ¾ in. diameter

bolts in standard holes. The member carries a dead load of 20 kips and a live load of 60 kips in tension. Calculate

at what length this tension member would cease to satisfy the recommended slenderness limit.

Solution:

Material Properties:

L4 4 ½ ASTM A36 Fy = 36 ksi Fu = 58 ksi Manual

Table 2-3

Geometric Properties:

L4 4 ½ Ag = 3.75 in.2 rz = 0.776 in. y = 1.18 in. = x Manual

Table 1-7

Calculate the required tensile strength LRFD ASD

Pu = 1.2(20 kips) + 1.6(60 kips)

= 120 kips

Pa = 20 kips + 60 kips

= 80.0 kips

Calculate the available tensile yield strength

Pn = FyAg = (36ksi)(3.75in.2) = 135 kips Eqn. D2-1

LRFD ASD

$ $#t = 0.90

#tPn = 0.90(135 kips) = 122 kips

$$ $$%t = 1.67

Pn /%t = (135 kips)/1.67 = 80.8 kips

Section D2

Calculate the available tensile rupture strength

Calculate U as the larger of the values from Table D3.1 case 2 or case 8

Case 2

U = "1x

l = "

1.18in.1

9.00 in.= 0.869

Case 8 with 4 or more fasteners per line in the direction of loading

U = 0.80

Use U = 0.869

Table D3.1

Case 2

Table D3.1

Case 8

Page 4: Ejemplos_

D-5

Calculate An

An = Ag – (dh + z)t

= 3.75 in.2 – (m in. + z in.)(2 in.) = 3.31 in.2

Calculate Ae

Ae = AnU = 3.31 in.2(0.869) = 2.88 in.2

Pn = FuAe = (58 ksi)(2.88 in.2) = 167 kips

Section D3.2

Section D3.3

Eqn. D3-1

Eqn. D2-2

LRFD ASD

$ $ #t = 0.75$#tPn = 0.75(167 kips) = 125 kips

$$ $$%t = 2.00

Pn/%t = (167 kips)/2.00 = 83.5 kips

Section D2

The L4 4 2 available tensile strength is governed by the tensile yielding limit state.

LRFD ASD

#tPn = 125 kips

125 kips > 120 kips o.k.

Pn/%t = 83.5kips

83.5 kips > 80.0 kips o.k.

Calculate recommended Lmax

Lmax = 300rz = & '* +, -

ft(300)(0.776 in.)

12.0 in. = 19.4 ft Section D1

Note: The L/r limit is a recommendation, not a requirement.