presa de almacenamiento
DESCRIPTION
Calculos de estabilidad para una presa de almacenamirntoTRANSCRIPT
ALUMNO: CAMPOS REYES JORGE
ALUMNO: CAMPOS REYES JORGEAPELLIDOS NOMBRE
REVISIN DE SECCIN DE LA ESTRUCTURA Y DETERMINACIN DE LAS CARGAS DE FATIGAANLISIS DE CARGA
FUERZAS VERTICALES (PESOS)
FUERZAKg
W1=6 X 3 X 220039,600.00
W2=((1.3575 X 2.275) / 2) X 22004,054.17
W3=9 X 4.3575 X 220086,278.50
W4=((9 X 0.90) / 2) X 22008,910.00
W5=((9 X 6.57) / 2) X 220065,043.00
SUMA DE FUERZAS VERTICALES203,885.67
DISTANCIAS AL PUNTO (D)DISTANCIA (A-D)
D111.8275 - 0.90 - 1.509.4275
D26.57 + (1.3575 X 2/3)7.4750
D36.57 + (4.3575/2)8.7488
D411.8275 - (0.90 X 2/3)11.2275
D5(6.57 X 2/3)4.3800
FUERZA HORIZONTAL (EMPUJE HIDROSTTICO)
PUNTO DE APLICACIN DEL EMPUJE HIDROSTTICO
MOMENTOS ESTTICOS RESPECTO A (D)
FUERZAVERTICALESHORIZONTALESBRAZOMOMENTOS
W139,600.009.4275373,329.00
W24,054.177.475030,304.92
W386,278.508.7488754,833.34
W48,910.0011.2275100,037.03
W565,043.004.3800284,888.34
E112,500.005.0000-562,500.00
SUMAS203,885.67980,892.63
DISTANCIA (X) DE LA RESULTANTE AL PUNTO (D)
EXCENTRICIDAD distancia entre la resultante al eje de la base
MEDIO TERCIO MEDIO
LO ANTERIOR INDICA QUE LA RESULTANTE CAE DENTRO DEL TERCIO MEDIO DE LA BASE, A UNA DISTANCIA DE 0.8685 m DE LA ORILLA POR LO CUAL NO HABR FATIGAS DE FLEXIN.CALCULO DE FATIGAS A LA SECCIN
CONCLUSINLA SECCIN PROPUESTA ES ACEPTABLE YA QUE SU DISEO NO PRESENTA FATIGAS DE FLEXIN, PERO ES CONVENIENTE AJUSTAR EL ANCHO DE LA BASE DISMINUYENDO LA PENDIENTE DEL PARAMENTO AGUAS ABAJO PARA DETERMINAR LA SECCIN OPTIMA.LOS CALCULOS ENTERIORES INDICAN QUE LA RESULTANTE CAE DENTRO DE LA BASE; QUE NO EST DENTRO DEL TERSIO MEDIO, UBICNDOSE UNA DISTANCIA DE 3.2883 M DE LA ORILLA Y HABRA FATIGAS DE FLEXION.