dr. daniel venencia - fundacion marie curie
TRANSCRIPT
![Page 1: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/1.jpg)
Planificación de oligometástasis vertebrales
basada en sistema ELEMENTS
Dr. Daniel VenenciaDr. Daniel Venencia
Instituto de Radioterapia – Fundación Marie Curie, Córdoba, ARGENTINA [email protected]
![Page 2: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/2.jpg)
SBRT columna (Hamilton et al. 1995)
• IGRT ?
• Sistema colimación ?
• Tiempos de irradiación ? , etc.
![Page 3: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/3.jpg)
SBRT columna: técnica tratamiento
• Es necesario haces modulados por concavidad del volumen de
tratamiento (IMRT – VMAT)
• IMRT múltiples campos (> 9campos)
• VMAT con múltiples arcos completos o parciales
Alta tasa de dosis – Tiempo de tratamiento• Alta tasa de dosis – Tiempo de tratamiento
• NO necesario incidencia no-coplanares
• IGRT on-line
![Page 4: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/4.jpg)
Simulación virtual esferas reflectoras
TAC
Definición de
• Cuerpo vertebral y pedículos localización mas típica
• Cuerpo vertebral Definición de
volúmenes
• Cuerpo vertebral completo
• Elemento dorsal
• OARs– Medula espinal PARCIAL (5-
6mm PTV)
– Tronco / Cauda equina
– Esófago
– Pulmones
– Riñones
– Hígado, etc.
![Page 5: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/5.jpg)
Simulación virtual esferas reflectoras
TAC
Definición de
volúmenes• PTV: 3fx – 12Gy
• PTV cercano o superpuesto con OARs
Prescripción
Dosis
PTV cercano o superpuesto con OARs
• Modalidad de tratamiento con alto
gradiente de dosis (IMRT, HybridARC,
VMAT)
• Tolerancia de OAR por sobre dosis a PTV
![Page 6: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/6.jpg)
Simulación virtual esferas reflectoras
TAC
Definición de
volúmenes
• PTV: 3fx – 12Gy
Prescripción
Dosis
Diferencia de dosis entre PTV y OARs => Planificación sofisticada
![Page 7: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/7.jpg)
SBRT 36y – 3fx
BED = 79Gy
![Page 8: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/8.jpg)
SBRT 36y – 3fx
BED = 79Gy
![Page 9: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/9.jpg)
• HybridArc™ combina dos métodos de tratamiento
probados para radiocirugía, Arcos dinámicos
modulados y haces de IMRT fijos, con una mezcla
automatizada y optimizada
![Page 10: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/10.jpg)
![Page 11: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/11.jpg)
Spine Mts. HybridArc
Novalis TX - SRS6MV
UMTotal = 4739
TiempoTotal = 7:15min
![Page 12: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/12.jpg)
Spine Mts. HybridArc vs. IMRT
IMRTHybridArc
TiempoHybridArc = 7:15 (-19%)
TiempoIMRT = 8:56
![Page 13: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/13.jpg)
SBRT Vertebras
ELEMENT
![Page 14: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/14.jpg)
Element Spine
![Page 15: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/15.jpg)
![Page 16: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/16.jpg)
![Page 17: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/17.jpg)
![Page 18: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/18.jpg)
![Page 19: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/19.jpg)
![Page 20: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/20.jpg)
![Page 21: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/21.jpg)
![Page 22: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/22.jpg)
![Page 23: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/23.jpg)
![Page 24: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/24.jpg)
IGRT en SBRT de vertebra
Imagen1
Imagen2
Control intra-tratamiento
![Page 25: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/25.jpg)
SBRT columna: End-to-End TEST
www.rpcmdanderson.org/rpc
![Page 26: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/26.jpg)
SBRT columna: End-to-End TEST
www.rpcmdanderson.org/rpc
![Page 27: Dr. Daniel Venencia - Fundacion Marie Curie](https://reader036.vdocuments.co/reader036/viewer/2022072411/62dc4a56eb515c68f44ee94e/html5/thumbnails/27.jpg)
Conclusiones
• SBRT columna es un tratamiento que – Requiere de exactitud milimétrica (MLC de alta resolución)
– IGRT inicial y control intratratamiento
– Requiere de un corto tiempo de tratamiento
• ELEMENT es un flujo de trabajo que incluye– Correccion de RNM por curvatura para fusión elástica con CT
– Segmentación automática de OAR
– Delimitación de GTV y CTV automático basado en guía internacional
– Planificación automática basada en Protocolos
– Tratamiento VMAT dedicado (alto gradiente de dosis)
– Corto tiempo de tratamiento
– Control de calidad