Download - Winslow Residence Presentation
-
8/14/2019 Winslow Residence Presentation
1/48
WINSLOW RESIDENCE
REPORT PRODUCED BY
STORM DAMAGE REPORT MARCH 30, 2007
-
8/14/2019 Winslow Residence Presentation
2/48
EVALUATION03/30/07WINSLOW RESIDENCE Page | 1
March 30, 2007
Winslow Residence352 Mulberry St.Howesville, NC 24345
Reference: Professional Cost Estimates to remediate, repair, and reconstructcurrent residence to a satisfactory and safe livable condition.
I am pleased to report that Construction Managers, Inc. has completed its professionalcost estimates of the Winslow home as requested. We have prepared two complete costestimates. One cost estimate represents repairing the present structure and grounds back to its original condition. The other cost estimate reflects demolition of the presentstructure and rebuilding a new home exactly the same as the present home.
The Winslow home is a one-story structure with full basement and attic space. The homecontains 2,371 heated square feet. The basement has 515 square feet. The main floor has1,490 square feet with a bonus room consisting of 366 square feet.
During our evaluation, we analyzed and determined the scope of work and price of allwork which will be required to reconstruct or build a new home. We have carefullyinspected every room of the Winslow existing home including the basement, attic, andexterior of the structure. We have viewed photographs taken after the impacts from treesup to the present. We have read the reports by Indoor Environmental Systems, Inc. andMcGee Enterprises, Inc. These reports give detail assessments for the current conditionregarding mold, water intrusion, and structural damage of the Winslow home. The reportsgive us the necessary information for mold remediation and what is required to return t hehome back to a satisfactory and safe environment. The Winslow home is uninhabitableand requires major mold remediation and moisture removal, with substantial constructionto remove and replace portions of the home that cannot be cleaned. My opinions as to theexpense of doing what is necessary to return the Winslow home to its proper conditionare accurately reflected in my attached reports.
-
8/14/2019 Winslow Residence Presentation
3/48
EVALUATION03/30/07WINSLOW RESIDENCE Page | 2
The primary factor causing the practical destruction of the Winslow home was treesfalling on the structure during an ice storm in February 2003.The massive impact from the trees and water intrusion has for the most part destroyedthis home. The home is severely contaminated by mold, and will require a thorough moldremediation, followed by clearance testing, before construction-related remediation andrepairs can commence.
The water intrusion and growth of mold will require removal and replacement of allflooring and carpets, roll-vinyl wall base, ceilings, and drywall throughout the structure.
There is evidence of several major roof leaks resulting from fallen trees. The leaks haveallowed excessive water intrusion and moisture into the structure which has contributedto the mold contamination
The moisture accumulation due to structural damage is the primary cause of the presentmold. The buildup of moisture can, and in this case did, feed mold growth.
I have been involved with many storm damage related projects and found this one to beone of the worst. The project repair and reconstruction costs far exceed the homes valueand one can build a new home for less money. It is my professional opinion the present
home should condemned.
Based on our cited references, cost estimates, and professional experience we standready, willing, and able to perform all work required to restore the home to its originalcondition for the amount of $614,301.00. We can rebuild an exact new home and groundsfor $448,466.00.
We hope to have the opportunity to work with you on this project.
Sincerely,
Sam E. Sasser
-
8/14/2019 Winslow Residence Presentation
4/48
ESTIMATE
Unsafe Living Conditions
Electrical wiring only works in some locations in the house. Could pose a fire hazard. Recommended solution:
- Completely rewire the house.- Salvage only electrical systems that function properly.
- Test and approve by a NC licensed electrician HVAC system consumed with moisture, mold and mildew.
Creates hostile breathing environment throughout the home. Recommended solution:
- Completely remove existing HVAC system and ductwork.
- Install new HVAC system and ductwork.- Test and approve by a NC licensed mechanical contractor.
WINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
5/48
ESTIMATE
Unsafe Living Conditions
Cracked foundation walls from the impact of the trees falling. Load bearing walls may not be properly supported from below. Foundation waterproofing has failed causing leaks in the basement. Recommended solution:
- Need to be certified by a NC certified structural engineer.- Repairs made accordingly per engineers recommendation.- New waterproofing installed per NC building codes.
Fireplace chimneys cracked and unusable. Use of fireplaces with cracks would trap gasses in the attic. Could pose a fire hazard. Recommended solution:
- Permanently seal all fireplaces and chimneys from further use.- OR demolish and rebuild them to meet NC building codes.
WINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
6/48
ESTIMATE
Unsafe Living Conditions
All interior/exterior finishes exhibit moisture causing mold and mildew growth. Recommended solution:
- Replace all insulation.- Replace structural framing where damage has occurred.- Remove and replace all roof shingles.
NOTE: Removal of all mold and mildew should occur during constructionon the house
WINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
7/48
DN
201
A B
203
C D
205 208
E
E
209
E
B
211
210
212
B
214
213202
339 SF
Living Room204
219 SF
Kitchen202
60 SF
Foyer 201 133 SF
Bedroom 4211
210 SF
Bedroom 3209
36 SF
Bath 2210
140 SF
Bedroom 2208
120 SF
Bedroom 1206
56 SF
Bath 1207
117 SF
Hall205
206
207
F i r e p l a c e
204
E
E
B
C h i m n e y
C h i m n e y
363 SF
Room203
FIRST FLOOR PLANWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
8/48
IMAGE #03WINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
9/48
ROOF PLANWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
10/48
IMAGE #05WINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
11/48
UP
101
37
37
102
373737
515 SF
Basement Room 1
101
877 SF
Basement Room 2
102
103
F i r e p l a c e
FIRST FLOOR PLANWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
12/48
IMAGE #09WINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
13/48
UP
101
37
37
102
373737
515 SF
Basement Room 1
101
877 SF
Basement Room 2
102
103
F i r e p l a c e
FIRST FLOOR PLANWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
14/48
IMAGE #15WINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
15/48
UP
101
37
37
102
373737
515 SF
Basement Room 1
101
877 SF
Basement Room 2
102
103
F i r e p l a c e
FIRST FLOOR PLANWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
16/48
IMAGE #21WINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
17/48
DN
201
A B
203
C D
205 208
E
E
209
E
B
211
210
212
B
214
213202
339 SF
Living Room204
219 SF
Kitchen202
60 SF
Foyer 201 133 SF
Bedroom 4211
210 SF
Bedroom 3209
36 SF
Bath 2210
140 SF
Bedroom 2208
120 SF
Bedroom 1206
56 SF
Bath 1207
117 SF
Hall205
206
207
F i r e p l a c e
204
E
E
B
C h i m n e y
C h i m n e y
363 SF
Room203
FIRST FLOOR PLANWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
18/48
IMAGE #31WINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
19/48
ESTIMATE
$0
$50,000
$100,000
$150,000
$200,000
G e n e r a l
D e m o l i t i o n
S i t e w o r k
C o n c r e t e
M a s o n r y
M e t a l s
W o o d / P l a s t i c
I n s u l a t i o n / R o o f
D o o r s / W i n d o w s
F i n i s h e s
H e a t i n g / A i r
E l e c t r i c a l
Detailed Cost ComparisonRestore Existing Build New
WINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
20/48
ESTIMATE
$0
$175,000
$350,000
$525,000
$700,000$614,301
$448,466
Total Cost Comparison
WINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
21/48
TIMELINEWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
22/48
TIMELINEWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
23/48
TIMELINEWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
24/48
TIMELINEWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
25/48
-
8/14/2019 Winslow Residence Presentation
26/48
TIMELINEWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
27/48
TIMELINEWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
28/48
TIMELINEWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
29/48
TIMELINEWINSLOW RESIDENCE 03/30/07
-
8/14/2019 Winslow Residence Presentation
30/48
TIMELINEWINSLOW RESIDENCE 03/30/07
Indoor Environmental Systems, Inc.
-
8/14/2019 Winslow Residence Presentation
31/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE
www.indoorenviron.com
Fungal/Mold Assessment ReportPrepared ForBob Cummins
3521 Community Church RD Pfafftown, NC 27040Inspection date: 01/31/2007
Prepared By:Indoor Environmental Systems, Inc
Steve McLeod924 West Chatham Cary, NC 27511
3521 Community Church RD Pfafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
32/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE2
SummaryThis is a follow-up inspection. The asses sment focuses on the condition of the personal items that arecurrently in the residence as well as an assessment as to how the home should be remediated. The scopeof services includes a limited visual and mechanical asses sment of easily accessed areas within theabove stated residence.
The results are presented in the following report. Included in the report are hypothesis regardingcausation and recommendations for remediation. This report pr ovides a general scope of work f or water
and fungal damage restoration. There are many hidden areas (wall and floor cavities) that have not yet been exposed. Indoor air quality testing for fungal components was not done during this assessment.
Inspector: Steve McLeod CEO CMC
Purpose: To assess the current condition of the building and the personal itemswithin. To make a recommendations as to the salvage- ability of the
personal items and general procedures for water damage and fungalrestoration.
Findings Water: The following areas continue to be affected by water intrusion, fluctuatinghumidity levels and temperature ranges; the majority of the structure andits contents: roof, attic, attic decking, 1 st Fl living area ceilings, suspectwater intrusion and microbial activity within the perimeter walls and floor
cavities, suspect structural damage to the fireplace, also the basementceilings, walls and floor, the air distribution system and occupants
personal contents within the building.
Condition Fungal: i 1st Floor Surfaces - Condition 3 (actual growth) There is visual fungalgrowth, on numerous personal items throughout the first floor. Basement - Condition 3 (actual fungal growth); There is visual f ungalgrowth on numerous personal items throughout the basement and in thework shop area.
Primary damage: Water intrusion has affected building material (swelling, shrinking anddelaminating of window molding, flooring, and furniture as well asfoundation wall cracks)
Secondary Damage: Fungal pollution and decay of affected building material personal itemsand homeowner complains of health symptoms which he associates withthe water and fungal damage. The homeowner has been living in the
building for approximately 3 years during the litigation process.Insect damage is the suspected cause of holes in the fabrics throughoutthe building.
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
33/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE3
Recommendations:
1. Contact environmental physician for occupants health risk assessment.
2. Inventory and consider discarding all personal porous items.
3. Inventory and clean all semi-porous and hard s urfaces which still havestructural integrity or other value. There is furniture within the housewhich may be cleaned but is not structurally sound due to repeated
expansion and contraction of the wood.
4. Structural evaluation of the building (walls on 1 s floor and foundation wallon basement level). The owner states there is structural damage to thefoundation due to the impact of a falling tree and reoccurring water intrusion. The cost of water and f ungal remediation to this structure may
be more than the cost of demolishing the building and building a newstructure.
5. Stabilize the environment:a. Repair leaks/moisture intrusion issues.
i. Finish drying in the building: structural engineer or roofing contractor should inspect the roof rafters andaddress thermal envelope issues such as cracked window
moldings and exterior brick finishes and I suspect perimeter wall sheathing may also be cracked due to housemovement and damage caused by repeated water intrusion.Once a structural integrity has been confirmed drying in of the building may commence; roof, siding, windows andfinishes.
b. 1st floor; remove all interior perimeter wall finishes: water repeatedly flowing through wall cavities has created anenvironment that may compromise the integrity of the wall system
building material, while creating an environment conducive tomicrobial growth. Visual inspection of the wall cavity for structural evaluation and fungal remediation is recommended.
c. Kitchen: cabinets, perimeter walls, ceiling, and floor.d. Living Room: perimeter walls, and floor e. Hallway: Ceiling and floor: Once the floor finish has been
removed and inspection for water intrusion down the hallway wallsneeds to be investigated. If water signs are evident to recommendexposing the hallway wall cavities as needed.
f. Bed #1: perimeter walls and floor.g. Bed #2: perimeter walls and floor.h. Bed #3: perimeter walls and floor.i. Master Bed room: perimeter walls and floor.
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
34/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE4
6. Finished Basement: Remove ceiling tiles, interior walls bottom plate(remove the entire interior walls if it is not cost effective to replace just atthe bottom plate) floor tile (may be asbestos), clean cinderblock walls asneeded.
a. Unfinished Basement: Remove the fungal growth from theexposed ceiling structure, Remove the fungal growth apply
biocide/sanitizer to the wood and encapsulate with appropriate product such as Anabec or Fosters 4020.
b. Air duct cleaning and encapsulation of suspect asbestos joint tape.
c.
Adjoining building (Far left side of building): Replace water damaged exterior wall board.d. Attic: clean in preparation for resurfacing water affected areas.
7. Clean all surfaces through-out the house clean to category 1 (refer toIICRC S520
8. Pass clearance testing less than or similar to background fungal sporelevels.
9. Resurface water damaged building framing/surfaces as needed with anti-fungal coating (recommend Anabec system of Fosters 4020).
10. Replace finishes.
3521 Community Church RD Pfafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
35/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE
5
Assessment ReportInspection date : 01-31-07
Inspector: Steve McLeod CEO CMC Purpose:
The owner, Mr. Paul Helms requested that IES, Inc. performed a follow-upassessment at the above stated address. Mr. Helms wanted me to assess the currentcondition of the building and the personal items within. To make a recommendations asto the salvage- ability of the personal items and present general procedures for water damage and fungal restoration. The assessment consists of a visual inspection in readilyassessable areas for fungal growth, moisture meter testing and picture taking.
Owners assessment:The owner states that in February 2003 the building sustained storm damage from
falling trees to the roof, walls, and foundation. The failing roof and cracked foundationallowed water intrusion during the preceding storms which further degraded the
perimeter walls, window frames, flooring finishes and personal items within the structure.
Mr. Helms had concerns about the condition of the personal items within theresidence and whether his items could be effectively cleaned. Mr. Helms stated thatwithin the last month the city had condemned his house and he has been in the process of removing personal items from a residence.
Background:The inspected building was built in 1961. It is a one story building with full
basement. Half the basement is/was a condition space. The approximate heated andcooled space is 2000 square feet; it is used as a family residence. Occupants were NOTliving in the building at the time of the inspection.
Areas of concern:
Location: Roof Issue: Water intrusion The roof covering looked well attached but Iquestioned its long-term ability to protect the structurefrom water intrusion
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
36/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE6
Location: Roof raftersIssue: Eaves are water stained. Water may affectwoods integrity, support fungal growth and wick
back into the structure.Hypothesis: Failing of the roof has allowed water to collect on the end of the roof rafters.Recommendations:
1. Contact a licensed contractor for structuralevaluation and remedy.
2.
All water affected building materialshould be remediated or replaced.
Location: Exterior wallsIssue: Brick walls appear to be bowed. Owner reports that impact of trees on the roof and thecontinued water intrusion caused walls to move. Hypothesis: Tree impacting on the building andthe ensuing water intrusion has had a structuralimpact and there is suspect microbialcontamination within the wall cavities.
Recommendations :3. Contact a licensed contractor/engineer for structural evaluation.
4. There should be further examination of theinternal wall cavity for microbial growth.
Location:Basement rear wall
Issue: Exterior wall is cracked which as reported by
the homeowner allows water to seep into the entire basement.
Hypothesis: Water can penetrate cracks andinfiltrates structure degrading building material andcreating an environment conducive for moldgrowth.
Recommendations:5. Contact a licensed contractor/engineer for
evaluation and remedy.
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
37/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE7
Location: AtticIssue: Water staining on surfaces in the attic.Hypothesis: Widespread roof failure has allowedwater intrusion.Recommendations:
6. Correct water intrusion issues.7. Clean and treat water and fungal aff ectedframing.
8. Remove water and fungal affected drywallas needed.
Location: AtticIssue: Water staining on surfaces in the attic.Hypothesis: Widespread roof failure has allowedwater intrusion.Recommendations:
9. Correct water intrusion issues.10. Clean and treat water and fungal affected
framing.11. Remove water and fungal affected drywall as
needed.
Location: AtticIssue: Water staining on surfaces in the attic.Hypothesis: Widespread roof failure has allowedwater intrusion.Recommendations:
12. Correct water intrusion issues.13. Clean and treat water and fungal aff ected
framing.14. Remove water and fungal affected drywall
and insulation as needed.
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
38/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE8
Location: Building material on the far leftside of the building.Issue: High building material moisturecontent.Hypothesis: Building material has beenunprotected from rainwater for an extended
period.Recommendations:
15. Replace or remediate all water andfungal affected building material.
Location: Building material on the far leftside of the building.Issue: High building material moisturecontent.Hypothesis: Building material has beenunprotected from Rainwater for an extended
period.Recommendations:
16. Replace or remediate all water andfungal affected building material.
Location: Building material on the far leftside of the building.Issue: High building material moisturecontent.Hypothesis: Building material has beenunprotected from rainwater for an extended
period.Recommendations:
17. Replace or remediate all water andfungal affected building material.
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
39/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE9
Location: Far left side of the building rafters.Issue: Visual fungal growth.Hypothesis: Building material exposed to water and caused fungal growth.Recommendations:
18. Replace or remediate all water and fungal
affected building material
Location: 1st floor Interior windowsIssue: Damage window framing may allow water to
penetrate surface cracks increasing the possibility of dampness and mold growth inside the walls.Hypothesis: Owner reported tree impact, racking of
the building during winter storms, wood expansionand contraction due to water intrusion has damagethe window frames.Recommendations:
19. Correct the water intrusion issues20. Contact a licensed contractor for structural
evaluation and remedy.21. All water affected building material should
be remediated or replaced.
Location: 1st floor fireplace.Issue: High building material moisture content.Homeowner observes water intrusion during
rainstorms.Hypothesis: Roof failure is allowing water intrusionaround the chimney.Recommendations:
22. Correct the water intrusion issues.23. Contact a licensed contractor for structural
evaluation and remedy.24. Water affected flooring system should be
exposed for water damage and fungalevaluation.
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
40/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE10
Location: 1st floor Hallway ceiling.Issue: There is evidence of water damaged ceilingson the first floor.Hypothesis: Water leaking through the roof isdamaging the ceilings.Recommendations:
25. Correct the water intrusion issues.26. Replaced damage ceiling and remediate allwater affected framing as needed.
Location: 1st floor kitchen.Issue: There is evidence of water damaged ceilingson the first floor.Hypothesis: Water leaking through the roof isdamaging the ceilings.
Recommendations:27. Correct the water intrusion issues.28. Replaced damage ceiling and remediate all
water affected framing as needed.
Location: Basement ceiling.Issue: Water damaged ceiling tiles.Hypothesis: Repeated water intrusion has
damaged the ceiling tiles.Recommendations:
29. Check ceiling tiles for asbestos content.30. Correct the water intrusion issues.31. All water affected ceiling tiles.32. Evaluate the ceiling plenum for fungal
and structural issues.
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
41/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE11
Location: First floor Kitchen.
Issue: Visual fungal growth is present on many
of the personal items. Settled dust is throughoutthe house and the dust will have elevated levelsof mold components.
Hypothesis: Water intrusion, uncontrolledtemperature and humidity have created anenvironment conducive to fungal growth. Fungal growth within the building hascontaminated occupants items.
Recommendations: a. Correct water intrusion issues.
b. Maintain relative humidity at 50%.c. Remove and or clean all water and fungal
affected building material.d. Remediate and/or replace personal items as
needed.
Issue: Insect damage
Hypothesis: The damaged thermal envelopeallows insects to enter the home which then thedamage fabrics.
Location: Stairway to basement.Issue: Evidence of microbial growth observedHypothesis: Water intrusion and elevatedhumidity has created an environment conduciveto fungal growth.Recommendations:
b. Correct water intrusion issue.33. Remove or remediate all water affected
building material: hallway wall panelingand carpet.
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
42/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE12
Location: Basement ceilingIssue: Water damaged ceiling tilesHypothesis: Repeated water intrusion has damagedthe ceiling tiles.
Recommendations: 34. Check ceiling tiles for asbestos content.35. Correct the water intrusion issues.36. Remove all water affected ceiling tiles37. Evaluate the ceiling plenum for fungal and
structural issues .
Location: Basement wall right frontIssue: Water damage and confirmed Stachybotrysfungal growth.Hypothesis: Water intrusion has created anenvironment conducive to fungal growth.Recommendations:
38. Correct the water intrusion issues.39. Remove or remediate all water and fungal
affected building material.40. Evaluate personal/storage items might per
item basis as to their r ecoverability andcutting to industry standards. If cleaningcosts are equal to or greater than 50% of thereplacement cost and visual fungal growthis present then replacement is recommend.
Location: Basement wall right front
Issue: Elevated moisture content of buildingmaterial.Hypothesis: Water intrusion has created anenvironment conducive to fungal growth.Recommendations:
41. Correct water intrusion issues.42. Dry and remediate according to industry
standards (IICRC S500 & S520)
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
43/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE
13
Location: Basement.Issue: Confirmed fungal growthHypothesis: Water intrusion and high relativehumidity is created an environment conduciveto fungal growth.Recommendations:
43. Correct water intrusion issues.44. Replace or remediate fungal affecteditems.
Location: Basement.
Issue: Aspergillus/Penicillium type funguswhich may have pathogenic and or toxigenic
properties is confirmed.
Location: BasementIssue: Aspergillus/Penicillium type funguswhich may have pathogenic and or toxigenic
properties is confirmed.
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
44/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE
14
Location: BasementIssue: Areas throughout the house are muchcluttered . All items have been exposed to highlevels of fungal contamination and should beremediated.Hypothesis: Fungal growth within the basementand other areas of the house has contaminatedoccupants items within the building.Recommendations:
45. Correct water intrusion issues.46. Maintain relative humidity at 50%.47. Remove and or clean all water and fungal
affected building material.48. Remediate and/or replace personal items as
needed.
Location: Basement/utility roomIssue: FloodingHypothesis: Exterior wall is cracked which asreported by the homeowner to allows water to seepinto the entire basement.Recommendations:
49. Correct water intrusion issues.50. Dry and remediate according to industry
standards (IICRC S500 & S520)
Location: BasementIssue: Areas throughout the house are muchcluttered . All items have been exposed to highlevels of fungal contamination and should beremediated.Hypothesis: Fungal growth within the basementand other areas of the house has contaminatedoccupants items within the building.
3521 Community Church RD P fafftown, NC 27040
U ili
-
8/14/2019 Winslow Residence Presentation
45/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE
15
Location: Utility room.Issue: Flooding.Hypothesis: Exterior wall is cracked which asreported by the homeowner to allows water to seepinto the entire basement.Recommendations:
51. Correct water intrusion issues.52. Dry and remediate according to industry
standards (IICRC S500 & S520)
Location: Basement utility room bottom plateIssue: Elevated moisture contentHypothesis: Exterior wall is cracked which asreported by the homeowner to allows water to seepinto the entire basement.Recommendations:
53. Correct water intrusion issues.54. Dry and remediate according to industry
standards (IICRC S500 & S520)
Location: Basement utility room bottom plateIssue: Aspergillus/Penicillium type fungus which
may have pathogenic and or toxigenic propertiesis confirmed.
Recommendations:55. Correct water intrusion issues.56. Dry and remediate according to industry
standards (IICRC S500 & S520)
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
46/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE
16
Location: Basement utility room air handling unitIssue: Debris and suspect fungal growthHypothesis: Moisture intrusion and high relativehumidity has created an environment within theducts that is conducive to fungal growth.Recommendations:
57. Clean the HVAC system according to the NADCA and EPA standards.
Location: Basement utility room air handling unitIssue: Suspect asbestos containing buildingmaterialHypothesis: Asbestos containing tape wascommonly used in this age building.Recommendations:
58. Exposed material should be encapsulated.
Location: Basement utility room air handling unitIssue: Debris and suspect fungal growthHypothesis: Moisture intrusion and high relativehumidity has created an environment within theducts that is conducive to fungal growth.Recommendations:
59. Clean the HVAC system according to the NADCA and EPA standards.
3521 Community Church RD P fafftown, NC 27040
-
8/14/2019 Winslow Residence Presentation
47/48
MOLDASSESSMENTREPORT
03/30/07WINSLOW RESIDENCE
17
End Notesi Fungal ConditionsAs defined by Standard and Reference Guide for Professional Mold Remediation IICRCS520Institute of Inspection Cleaning and Restoration Certification
Condition 1 (normal fungal ecology); an indoor environment that may have mold spores, fungal fragments or traces of actualgrowth whose identity, location and quantity are reflective of a normal fungal ecology for a similar indoor environment.
Condition 2 (settled spores); an indoor environment which is primarily contaminated with settled spores that were disbursedirectly or indirectly from a condition 3 area, and which may have traces of actual growth.
Condition 3 (actual growth) an indoor environment contaminated with the presence of actual mold growth and associatedspores. Actual growth includes growth that is active or dormant, visible or hidden.
-
8/14/2019 Winslow Residence Presentation
48/48
WINSLOW RESIDENCESAMPLE REPORT
THANK YOU FOR TAKING THE TIME TO REVIEW THIS SAMPLEREPORT. WE HOPE THIS WAS HELPFUL TO DEMONSTRATE HOW
BENEFICIAL OUR SERVICES CAN BE TO YOU IN YOURCONSTRUCTION CLAIMS CASES. PLEASE CONTACT US AT THE
WEB ADDRESS BELOW ABOUT A CONSULTATION.