CALCULO DE LA DOTACION DE AGUA PARA UNAVIVIENDA UNIFAMILIAR
SEGN RNC HASTA 200 M2 LA DOTACION SERA
1500LTS/DIA
CALCULO DE VOLUMEN DE CISTERNA Y TANQUE ELEVADO:
CALCULOTOTAL (L/D)M3M3
VOL. CISTERNA: 3/4 X DOT.3/4 X 150011251.132.25
M3
VOL. T. ELEVADO:1/3 X DOT.1/3 X1500500.00.501.00
DIMENCIONANDO CISTERNA Y TANQUE ELVADO (hallando alt.)
CISTERNA:VOL CIST.(M3)AREA(M2)ALTURA(M)NORMATOTAL (M)
2.252.880.780.81.58
NOTA:Sele agrega 0,80 mts a la altura de tanque elevado y cisterna
TANQUE ELVADO:VOL T.E(M3)AREA(M2)ALTURA(M)NORMATOTAL (M)
1.001.250.800.81.60