  • CALCULO POTENCIA INSTALADA, MAXIMA DEMANDA Y FACTOR DE SIMULTANEIDAD

    VIVIENDA DE TRES PISOSAREA DEL TERRENO 100.00 M2AREA CONSTRUIDO POR PISO 68.10 M2AREA LIBRE 31.90 M2

    1. POTENCIA INSTALADAALUMBRADO POR AREA DE PISO M2 25 W / M2 (Codig. Elect)

    PRIMER PISO 68.10 25 W / M2 1,702.50 WSEGUNDO PISO 68.10 25 W / M2 1,702.50 WTERCER PISO 68.10 25 W / M2 1,702.50 W

    ALUMBRADO AREA LIBRE 5 W / M2 (Codig. Elect)(Area terreno - area const. Primer Piso) 31.90 5 W / M2 159.50 W

    TOTAL 3,564.50 WCARGA MOVIL TOMACORRIENTESSegn NTP- varian de 2000W a 5000 W asumir 4,000.00 W

    ELECTROBOMBA 1 HP 735.00 W

    CALENTADOR 100 lts 1,200.00 WPOTENCIA INSTALADA TOTAL 9,499.50 W

    2. MAXIMA DEMANDAALUMBRADO HASTA 2000 W 100 % Cod. Elect 2,000.00 WLOS SIGUIENTES 118,000 W 35 % ( 3,564.50 -2,0 (1,564.50*0.3 547.575 WSe resta de 3,564.50 W (carga total de alumbrado y tomacorrientes = 2000 W)Quedan: 3,564.50 W 2000 W 1,564.50 W AL 35 %

    CARGA MOVIL TOMACORRIENTES asumido 4,000.00 2,000.00 WSe toma el 50 % de la carga movil 4000 W al 50 %

    ELECTROBOMBA 1 HP 735 W al 100 % 735.00 W

    CALENTADOR 100 W 1200 W 75% 900.00 W

    MAXIMA DEMANDA 6,182.58 W

    3. FACTOR DE SIMULTANEIDAD Factor entre Maxima Demanda y Potencia Instalada MD / PI 0.65

  • DISEO DE CONDUCTORES ELECTRICOSI = Dem/(0.80 x 220) I = I X FSEG

    176

    CIRCUITO PUNTOS WATT/PTO DEMANDA CORRIENTE INTENSIDAD FACT SEG AMPERIOS COD. ELECT

    CIRCUITO DE ALUMBRADO

    CIRCUITO C-1 23 80 1840 220 0.8 10.45 1.25 13.07 2.5 mm

    CIRCUITO C-2 21 80 1680 220 0.8 9.55 1.25 11.93 2.5 mm

    CIRCUITO DE TOMACORRIENTES

    CIRCUITO C-3 22 150 3300 220 0.8 18.75 1.25 23.44 2.5 mm

    CIRCUITO C-4 25 150 3750 220 0.8 21.31 1.25 26.63 2.5 mm

    CIRCUITO ELECTROBOMBA

    POTENCIA HP 1 375 375 220 0.8 2.13 1.25 2.66 2.5 mm

    CALENTADOR 1 1200 900 220 0.8 5.11 1.25 6.39 2.5 mm

    ALIMENTADOR 1 6182 6182 220 0.8 35.13 1.25 43.91 16.00 mm **

    cos

  • CAIDA DE TENSIONFORMULA = 1/0.0175

    v = 2 *I *L / * S

    CALCULO DE CAIDA DE TENSION I (AMP) SECCION LONGITUD POTENCIA COBRE CAIDA TENSIONCAIDA MAX.

    CIRCUITO DE ALUMBRADO 3%(220 V)

    CIRCUITO C-1 10.45 2.5 11 1840 57.143 1.61 6.6

    CIRCUITO C-2 9.55 2.5 9.5 1680 57.143 1.27 6.6

    CIRCUITO DE TOMACORRIENTES

    CIRCUITO C-3 18.75 2.5 11 3300 57.143 2.89 6.6

    CIRCUITO C-4 21.31 2.5 10 3750 57.143 2.98 6.6

    ELECTROBOMBA

    POTENCIA HP 2.13 2.5 9 375 57.143 0.27 6.6

    CALENTADOR 5.11 2.5 15 900 57.143 1.07 6.6

    ALIMENTADOR 35.13 16 13 6182 57.143 1.00 6.6

    Hoja1Hoja2