aprovechamiento-01

14
DISEÑO DE PEQUEÑA CENTRAL HIDROELECTRICA DATOS Poblacion a beneficiar = 26400 habitantes 7.80% 10 años 10.5 0.7 B = Ancho del rio= 4 m 1.00% Trabajo a plena carga = 90 % HISTORIAL DE CAUDALES MES AÑO 1 2 3 4 5 6 7 8 1 3.74 4.35 3.77 3.53 3.15 3.39 4.00 3.42 2 3.96 4.10 4.03 3.90 3.66 3.61 3.75 3.68 3 4.46 4.35 4.23 4.42 4.55 4.11 4.00 3.88 4 3.95 3.87 3.76 3.45 3.43 3.60 3.52 3.41 5 2.49 3.11 3.19 2.46 2.83 2.14 2.76 2.84 6 2.15 2.23 2.95 2.35 2.50 1.80 1.88 2.60 7 1.67 1.53 2.15 2.11 1.67 1.32 1.18 1.80 8 1.16 1.19 1.33 1.50 1.03 0.81 0.84 0.98 9 0.87 0.83 0.85 0.93 0.89 0.82 0.78 0.80 10 0.87 0.83 0.84 0.86 0.86 0.82 0.88 0.89 11 1.03 1.15 0.95 1.90 0.93 0.88 0.80 0.80 12 1.47 2.11 2.15 1.53 2.74 1.12 1.76 2.80 Qmax = m 3 /s Qmin = m 3 /s Srio= r

Upload: rafael-villon

Post on 11-Nov-2015

3 views

Category:

Documents


0 download

DESCRIPTION

fdsfds

TRANSCRIPT

HIDRO-DEMANDADISEO DE PEQUEA CENTRAL HIDROELECTRICADATOSPoblacion a beneficiar =26400habitantes 7.80% 10aos6.61Qmax =10.5m3/s5.61Qmin =0.7m3/s5.470B = Ancho del rio=4m5.20Srio=1.00%5.10Trabajo a plena carga=90%5.104.990HISTORIAL DE CAUDALES4.9MESAO4.8123456789104.7813.744.353.773.533.153.394.003.423.182.804.723.964.104.033.903.663.613.753.683.553.314.554.734.464.354.234.424.554.114.003.884.074.200.684.6743.953.873.763.453.433.603.523.413.103.084.610.6852.493.113.192.462.832.142.762.842.112.484.574.5562.152.232.952.352.501.801.882.602.002.154.5471.671.532.152.111.671.321.181.801.761.324.581.161.191.331.501.030.810.840.981.150.684.590.870.830.850.930.890.820.780.800.780.744.4100.870.830.840.860.860.820.880.890.900.814.38111.031.150.951.900.930.880.800.800.850.884.34121.472.112.151.532.741.121.762.802.181.394.324.251) CALCULO DEL CAUDAL DE DISEO4.18En base a esta informacin de Historia de Caudales se construir la curva de frecuencias y caudales (Histograma)4.114.14.05CURVA DE FRECUENCIA Y CURVA DE CAUDALES4.02Variacion de CaudalesCurva de Curva de 4.02FrecuenciasCaudales4Nmero%Nmero%003.9904.554.640.000.000.0003.993.70833333334.454.541.000.810.8003.983.6254.354.441.000.821.7003.9210.6254.254.343.002.554.2003.9104.154.240.000.054.2003.896.754.054.142.001.775.8003.819.8753.954.043.002.5108.3003.816.04166666673.853.945.004.21512.5003.79.3753.753.843.002.51815.0003.699.1253.653.743.002.52117.5003.688.8753.553.643.002.52420.0003.68.6253.453.543.002.52722.5003.588.3753.353.443.002.53025.0003.3410.83333333333.253.344.003.33428.3003.32.6253.153.241.000.83529.2003.267.6253.053.143.002.53831.7003.17.3752.953.043.002.54134.20032.3752.852.941.000.84235.000302.752.840.000.04235.0002.9811.04166666672.652.745.004.24739.2002.92.1252.552.641.000.84840.0012.872.04166666672.452.541.000.84940.8022.677.83333333332.352.444.003.35344.2022.651.8752.252.341.000.85445.0022.6402.152.240.000.05445.0022.6110.252.052.146.005.06050.0042.566.51.952.044.003.36453.3032.51.54166666671.851.941.000.86554.2022.382.91666666671.751.842.001.76755.8042.35.51.651.744.003.37159.2042.32.58333333331.551.642.001.77360.8032.301.451.540.000.07360.8042.284.51.351.444.003.37764.2022.261.04166666671.251.341.000.87865.0002.262.8751.151.243.002.58167.5052.054.3751.051.145.004.28671.7011.620.7916666667120.00100.00.951.041.000.88772.52.83333333330.850.944.003.39175.88.750.750.8414.0011.710587.57.04166666670.650.7413.0010.811898.30.91666666670.550.642.001.7120100.000.450.540.000.0120100.000.350.440.000.0120100.01.1800.250.340.000.0120100.000.150.240.000.0120100.000.050.140.000.0120100.0000.040.000.0120100.0ERROR:#REF!411.11.091.081.08120.001.081.081.051.0510.950.950.940.920.910.910.90.90.90.90.890.880.860.820.810.780.76Segn la curva de duracin de frecuencias, un trabajo a plena carga de 90% le corresponde un caudal de diseo de 0.75 m/seg.

Q=0.75m3/sQmin=0.68m3/s

2) CALCULO DEL SALTO '' H ''

2.1) calculo de la demanda Potencial (Dp)

De la tabla

POBLACION (HABITANTES)DEMANDA DE POTENCIA500 - 100015 Kw - 35 Kw1000 - 200035 Kw - 80 Kw2000 - 400080 Kw - 180 Kw4000 - 10000180 Kw - 500 Kw10000 - 20000500 Kw - 1200 Kw

Dp = 1584Kw(Ver Justificacin)

2.2) Calculo de la demanda Futura Df

Dp = Demanda Potencial Razon de crecimiento promedio anual de la demanda de energia Tiemo de retorno

Df =3356.93Kwtrabajamos:Df = Pot=3357Kw

2.3) Clculo del Salto HDe acuerdo con la expresin de potencia de un aprovechamiento hidroenergtico.

P=9.81 x Q x H x nn=50%

Remplazando Valores tenemos: H=913m Hdisponible913m

2.4) Clculo del Caudal segn la topografa con la que se cuentaSi colocamos Hdisponible para calcular el caudal necesario

Q = P/ (9.81 x H x n)

Q=0.75m3/s

JUSTIFICACIONESJUSTIFICACIONES PARA EL DISEO1Para el Calculo de la Demanda Potencial en los calculos anteriores se ha supuesto que la potencia instalada percpita ser de 60 w/habSe tiene una poblacin de 26400 habitantesResulta Dp =1584KwP.Percap.Dem.P (kw)235w/hab3540w/hab8045w/hab18050w/hab50060w/hab1200