    UNIVERSIDAD NACIONAL DE PIURA

    FACULTAD DE INGENIERIA DE MINAS

    TEMA : VENTILACION DE

    LA MINA RAURA

    INTEGRANTES : Zambrano Hurtado Gloria

    Ramos Garca Jose LuisLpez Ramrez Juan Carlos

    Merino Carhuachinchay Jhermain

    Ojeda Carrin Keber

    PROFESOR : ING. JOSE CHANG VALDIVIEZO.

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    2/36

    MINA RAURA: UBICACION

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    3/36

    UBICACIN Y ACCESO

    UBICACION:

    Distrito: San Miguel de Cauri

    Provincia: Lauricocha

    Dpto: HunucoALTITUD: 4,700 m.s.n.m.

    ACCESO:

    1- Huacho-Sayn-Oyn-Raura

    2- Hunuco-Jess-Cauri-Raura

    3- Pasco-Oyn-Raura

    Lima La Oroya

    Cerro de PascoRaura Oyn

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    4/36

    CA. MINERA RAURA S.A. RECIBI EN DICIEMBRE

    DEL 2005 LA CERTIFICACIN INTERNACIONAL EN ISO-14001 (AUDITORA INTERNACIONAL BUREAU VERITAS)

    LA AUDITORIA INTERNACIONAL DE OHSAS SEREALIZARA EN EL MES DE OCTUBRE DEL 2006

    SE ASEGURA QUE NUESTROS PROCESOS YNUESTRAS OPERACIONES CUMPLEN CON LOSESTNDARES INTERNACIONALES DE SEGURIDAD YCALIDAD AMBIENTAL

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    5/36

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    6/36

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    7/36

    INTRODUCCION- LA UNIDAD MINERA RAURA, DE PROPIEDAD DE LA CA.MINERA RAURA S.A. INICI SUS OPERACIONES EN 1960.ESTAS OPERACIONES SE EJECUTARON MEDIANTE LABORESSUBTERRNEAS CON PRODUCCIN DE MINERALPOLIMETLICO

    - ACTUALMENTE, CA. MINERA RAURA S.A., ES UNAEMPRESA PERUANA DE LA MEDIANA MINERA, DEDICADA ALAS ACTIVIDADES MINERO METALRGICAS DE EXPLOTACIN,BENEFICIO Y COMERCIALIZACIN DE CONCENTRADOS DE

    MINERALES POLIMETLICOS (ZINC, PLATA, COBRE Y PLOMO).

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    8/36

    - LOS MTODOS DE EXPLOTACIN SON: SHIRINKAGE,CORTE Y RELLENO ASCENDENTE (BREASTING Y TALADROSINCLINADOS), CMARAS Y PILARES, BLOCK CAVING (TALADROSLARGOS).

    - COMPAA MINERA RAURA S.A. BUSCA DESARROLLAR UNSISTEMA DE VENTILACIN PTIMO QUE BRINDE UN AMBIENTESEGURO , SALUDABLE Y CMODO AL PERSONAL EN INTERIORMINA

    - COMPAA MINERA RAURA S.A. BUSCA LOGRAR AHORROS

    EN SUS COSTOS DE OPERACIN REFERENTE A VENTILACIN

    - EN UNA MINA COMO RAURA NO SE PUEDE LOGRARBUENOS RESULTADOS EN VENTILACIN SINO SE CUENTA CONLOS EQUIPOS Y LA INFRAESTRUCTURA ADECUADOS, ELDIRECCIONAMIENTO Y VOLUMEN DE AIRE REQUERIDO SE DEBELOGRAR CON AYUDA DE VENTILACIN MECNICA

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    9/36

    PLANO ISOMETICO - RAURA

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    10/36

    CIRCUITO DE VENTILACION PRIMARIO

    INGRESO DE AIRE A CATUVA

    Nv 300 (SHUCSHAPAJ) INGRESA AIRE

    Nv 380 (TINQUICOCHA) INGRESA AIRE

    Nv 590 (HIDRO) INGRESA AIRENv 630 (CATUVA) INGRESA AIRE

    Nv 700 (CATUVA) INGRESA AIRE

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    11/36

    CIRCUITO PRIMARIO CATUVA

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    12/36

    CIRCUITO DE VENTILACION PRIMARIOSALIDA DE AIRE CATUVANv 630, RB 66

    Nv 630, RB 69

    Nv 630, RB 70Nv 630, RB 02

    Nv 630, RB 23

    Nv 630, RB 10

    Nv 700, RB 09

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    13/36

    BALANCE DE AIRE PARA MINA CATUVANECESIDADES DE AIRE PARA CATUVA

    POR LA CANTIDAD DE HOMBRES POR GUARDIA148 hombres x 6.0 m3/min 888.00 m3/minPOR EL USO DE EQUIPO DIESEL

    1681.50 HP x 3.0 m3/HP/min 5,044.50 m3/minPOR EL USO DE EXPLOSIVOS25.0 m/min x 8 Nv x 11.11 m2 2,222.00 m3/min

    TOTAL 8,154.50 m3/min

    287,972.90 CFM

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    14/36

    BALANCE DE AIRE PARA MINA CATUVAINGRESO DE AIRE ( ANTES )

    LUGAR DE INGRESO m3/min CFM

    Nv 300, Cx 575 1,534.91 54,204.73

    Nv 380, Cr 080 SW 594.45 20,992.78

    Nv 380 199.32 7,038.91

    Nv 590, Cr 070 SW 528.96 18,680.01

    Nv 590 RB 140.99 4,979.00

    Nv 590, Gl 480 86.14 3,041.99

    Nv 630, Cx 230 SW 2,062.54 72,837.77

    Nv 700 114.94 4,059.06

    TOTAL 5,262.25 185,834.25

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    15/36

    BALANCE DE AIRE PARA MINA CATUVAINGRESO DE AIRE ( DESPUES )

    LUGAR DE INGRESO m3/min CFM

    Nv 300, Cx 575 2,944.75 104,000.50

    Nv 380, Cr 080 SW 594.45 20,992.78

    Nv 380 199.32 7,038.91

    Nv 590, Cr 070 SW 1,529.11 54,000.00

    Nv 590 RB 140.99 4,979.00

    Nv 590, Gl 480 86.14 3,041.99

    Nv 630, Cx 230 SW 3123.35 110,300.00

    Nv 700 114.94 4,059.06

    TOTAL 8,733.27 308,412.24

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    16/36

    RESUMEN BALANCE DE AIRE CIRCUITO PRINCIPAL

    CATUVA

    INGRESO

    DE AIRE

    CFM

    NECESIDAD

    DE AIRE

    CFM

    COBERTURA

    %

    OBSERVACION

    185,834.25 287,972.90 64.50

    ANTES DEINSTALAR

    VENTILADORES

    308,412.24 287,972.90 107.10

    DESPUES DE LAINSTALACION DEVENTILADORES

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    17/36

    - LAS CORRECCIONES HECHAS AL CIRCUITO PRINCIPAL:INCREMENTO DE CAUDAL DE AIRE DE 185,834.25 CFM A

    308,412.24 CFM

    - SE LOGRO INSTALANDO 02 VENTILADORES DE 100,000 CFM Y01 VENTILADOR DE 50,000 CFM, AS COMO ELMEJORAMIENTO DE PUERTAS Y TAPONES DE VENTILACION

    - - CON ESTA CORRECCION EL SISTEMA DE VENTILACION

    CUMPLE CON LA NECESIDAD DE AIRE REQUERIDO EN MINACATUVA

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    18/36

    PUERTA DE VENTILACION

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    19/36

    VENTILACION SECUNDARIA

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    20/36

    - PARA LOS CIRCUITOS SECUNDARIOS, LUEGO DE LAEVALUACION SE DETERMINO COMPLETAR LASPREPARACIONES EN LAS LABORES DE EXPLOTACION

    - LA CONSTRUCCION DE DUCTOS METALICOS PARA ELIMINARCAIDAS DE PRESION EN LOS CODOS

    - EL USO DE MANGAS DE VENTILACION CON LOS DIAMETROSAPROPIADOS

    - PARA LABORES MAYORES A 60.0 m DE LONGITUD SEINSTALAN VENTILADORES EN SERIE GENERALMENTE CADA

    100.0 m (DEPENDIENDO DE LA CAPACIDAD DEL VENTILADOR)

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    21/36

    VENTILADOR SECUNDARIO

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    22/36

    DISTRIBUCION Y COSTO DE VENTILACION ANTERIOR

    VENTILADOR MOTOR FACTOR CAPACIDAD Kw-h $/Kw-hora $/dia $/ao UBICACIN

    (Kw) (horas) (CFM)

    VMR-12 75.00 1.0 50,000 1800.00 0.045 81.00 29160.00 Nv 300

    VMR-13 11.25 1.0 8,000 270.00 0.045 12.15 4374.00 Nv 300, Tj 835

    VMR-14 95.25 0.8 50,000 1714.50 0.045 77.15 27774.90 Nv 300,Cx 035

    VMR-11 22.50 1.0 20,000 540.00 0.045 24.30 8748.00 Nv 340, Rp 895

    VMR-10 24.00 1.0 20,000 576.00 0.045 25.92 9331.20 Nv 380, Cx 100

    VMR-09 11.25 1.0 15,000 270.00 0.045 12.15 4374.00 Nv 380, Cx 315VMR-05 37.50 0.8 18,000 675.00 0.045 30.38 10935.00 Nv 490, Cx 943

    VMR-06 15.00 0.8 15,000 270.00 0.045 12.15 4374.00 Nv 490, Cx 943

    VMR-08 15.00 1.0 15,000 360.00 0.045 16.20 5832.00 Nv 490

    VMR-03 41.25 0.8 20,000 742.50 0.045 33.41 12028.50 Nv 590, Cx 112

    VMR-04 34.50 0.8 20,000 621.00 0.045 27.95 10060.20 Nv 540, Tj 082

    VMR-01 191.25 1.0 120,000 4590.00 0.045 206.5 74358.00 Nv 630

    VMR-02 150.00 1.0 100,000 3600.00 0.045 162.0 58320.00 Nv 630

    VMR-15 24.00 0.8 15,000 432.00 0.045 19.44 6998.40 Nv 630, Tj 990

    VMR-16 24.00 0.8 20,000 432.00 0.045 19.44 6998.40 Nv 740, Tj 130

    VMR-27 40.73 1.0 20,000 977.40 0.045 43.98 15833.88 Nv 440, COBRI

    TOTAL 812.48 17870.4 804.1 255966.4

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    23/36

    DISTRIBUCION Y COSTO DE VENTILACION ACTUAL

    VENTILADOR MOTOR FACTOR CAPACIDAD Kw-h $/Kw-hora $/dia $/ao UBICACIN

    (Kw) (horas) (CFM)

    VMR-12 75.00 1.0 50,000 1800.00 0.045 81.00 29160.00 Nv 300

    VMR-13 11.25 1.0 8,000 270.00 0.045 12.15 4374.00 Nv 300, Tj 835

    VMR-09 11.25 1.0 15,000 270.00 0.045 12.15 4374.00 Nv 380, Cx 315

    VMR-06 15.00 0.8 15,000 270.00 0.045 12.15 4374.00 Nv 490, Cx 943

    VMR-08 15.00 1.0 15,000 360.00 0.045 16.20 5832.00 Nv 490

    VMR-03 41.25 0.8 20,000 742.50 0.045 33.41 12028.50 Nv 590, Cx 112

    VMR-01 191.25 1.0 120,000 4590.00 0.045 206.55 74358.00 Nv 630

    VMR-02 150.00 1.0 100,000 3600.00 0.045 162.00 58320.00 Nv 630

    VMR-15 24.00 0.8 15,000 432.00 0.045 19.44 6998.40 Nv 630, Tj 990

    TOTAL 534.00 12334.50 555.05 166284.90

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    24/36

    VENTAJAS LOGRADAS

    - SE REDUJO EL NUMERO DE VENTILADORES INSTALADOS DE16 A 09, CON EL CONSIGUIENTE AHORRO DE ENERGIA

    - SE DA MAS EFICIENCIA A LAS OPERACIONES DEBIDO A QUE

    LOS TIEMPOS PARA VENTILACION SON MENORES

    - DEBIDO A QUE SE CONSTRUYERON CHIMENEAS DEVENTILACION EN LAS LABORES SE HACE POSIBLE EL USODE ANFO

    - EL AHORRO EN VENTILACION CALCULADO SOLO PARACATUVA ES: 89,681.58 US$/AO

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    25/36

    VENTILACION SECUNDARIA

    RB-83 Y RB 79 NV 540 A 300 B BALILLA

    NV-540

    NV-300

    NV-380

    NV-490

    RB-83 RB-79

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    26/36

    PLANTA RB-83 NV 540 A 300 B. BALILLA

    NV-540

    NV-300

    NV-380

    NV-490RB-83

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    27/36

    SECCION RB-83 NV 540 A 300 B BALILLA

    NV-540

    NV-300

    NV-380

    NV-490

    RB-83

    INCLINACION =-79

    LONGITUD =238.00 MTS CUERPO DE MINERAL

    SUBNIVEL

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    28/36

    VENTILACION SECUNDARIA

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    29/36

    VENTILACION SECUNDARIA

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    30/36

    CALIDAD DEL AIRE

    - UN BUEN SISTEMA DE VENTILACIN REQUIERE TAMBIN EL

    MONITOREO CONSTANTE DE VEHCULOS QUE INGRESAN AINTERIOR MINA, QUE LA EMISION DE GASES DE ESTOSVEHICULOS ESTE CONTROLADA

    - LA CANTIDAD DE AIRE NO DEBE SER MENOR A 3.0 m3/min

    POR CADA HP QUE DESARROLLEN LOS EQUIPOS

    - LA CALIDAD DEL AIRE ESTA EN FUNCIN AL CONTENIDO DEO2 (MAYOR A 19.5% VOLUMEN)

    - PARA EL USO DE ANFO LA VELOCIDAD NO DEBER SERMENOR A 25 m3/min

    - LA EVALUACIN DEL CIRCUITO DE VENTILACIN SEREALIZARA EN UN PERIODO MENOR A 06 MESES

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    31/36

    CALIDAD DEL AIRE

    MONITOREO

    SEMANAL DE CO

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    32/36

    CONCLUSIONES:- EL NUMERO DE PERSONAL EN CATUVA ES:

    EE OPEMISS SRL : 65 hombres

    EE MICONG SRL : 55 hombresAESA MINING : 13 hombresOTROS : 15 hombresHACEN UN TOTAL DE 148 hombres, REQUIRIENDO UN TOTAL DE888.00 m3/min DE AIRE

    - EN MINA CATUVA SE TIENEN EN OPERACIN EN INTERIOR MINA ENSIMULTANEO DURANTE EL TURNO:SCOOPTRAMS : 06 undC BAJO PERFIL: 02 undCAMIONETAS : 13 undCAMIONES : 06 und

    VOLQUETES : 08 undEQ SERVICIOS : 02 undHACIENDO UN TOTAL DE 1681.50 HP Y REQUIRIENDO UN CAUDAL DE5,044.50 m3/min DE AIRE

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    33/36

    - EL PROBLE MA DE LA VENTILACION SE AGUDIZA DEBIDO A QUE LASLABORES SE POLARIZAN

    - EL CIRCUITO PRIMARIO DE VENTILACION EN CATUVA ESTADISEADO PARA SUMINISTRAR AIRE A CADA LABOR DE LA MINA,PARA ELLO ES NECESARIO ORGANIZAR LA VENTILACIONSECUNDARIA

    - LAS LABORES DEBEN CUMPLIR SUS ETAPAS HASTA QUEDARAPTAS PARA SU EXPLOTACION, UNA BUENA PLANIFICACION DELABORES AYUDARA A EVITAR FUTUROS PROBLEMAS DEVENTILACION

    - LAS CHIMENEAS DE VENTILACION QUE SON PARTE DEL CIRCUITO

    PRINCIPAL DE VENTILACION TAMBIEN PUEDEN SER USADAS COMOCHIMENEAS DE SERVICIOS PARA LINEA ELECTRICA, TUBERIA DERH. AGUA, AIRE COMPRIMIDO, ETC, Y DEBEN SER INDEPENDIENTESDE LAS LABORES QUE VENTILAN LOS TAJEOS

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    34/36

    - EL CIRCUITO PRINCIPAL DE VENTILACION EN CATUVA SE

    ALIMENTA DE AIRE LIMPIO POR 05 NIVELES DE LA MINA ELCUAL SE CONDUCE A LAS LABORES EN OPERACIN

    - 02 NIVELES ALIMENTAN AIRE EN DESCENSO Y 03 NIVELESALIMENTAN AIRE ASCENDENTE

    - TODO ESTE AIRE SE HACE LLEGAR AL Nv 540 DE LA MINA QUE

    SE CONVIERTE EN EL CENTRO DEL SISTEMA DE VENTILACIONY DESDE ALLI SE EXTRAE CON 02 VENTILADORES DE 100,000CFM A TRAVES DE RBs A SUPERFICIE

    - SE DEBE MANEJAR EL CONCEPTO DE INSTALAR

    VENTILADORES SECUNDARIOS SOLO EN LABORES DE AVANCE

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    35/36

    BIBLIOGRAFIAwww.todoexpertos.comwww.arqhys.com/ventilacion-minas.

    www.derenatura.com/elrinconminero

    www.raura.com

  • 7/16/2019 67653582 Ventilacion de La Mina Raura

    36/36