ULTRABONDECO V4 CONDUCTIVE

FICHA TÉCNICA

CAMPOS DE APLICACIÓN • La unión de vinilo conductora, caucho y el suelo textil revestimien-tos en interiores. Algunos ejemplos de aplicación Utilice Ultrabond Eco V4 conductiva para la unión: • pisos de vinilo conductor en todas las áreas El vertido, cuando de la electricidad estática puede provocar explosiones o perturbe aparatos eléctricos y electrónicos, por ejemplo quirúrgico salas, laboratorios químicos y fábricas, Areas que contiene instrumentos electrónicos, procesamiento de datos centros, etc.; • alfombras y suelos de punzonado conductora EN todos los sustratos absorben-tes y humedad estable Normalmente utilizados en la construcción.

CARACTERÍSTICAS TÉCNICAS • Ultrabond Eco V4 conductiva es una resina sintética adhesivo basado en dispersión acuosa con fibras especiales Que garanticen la conductividad eléctrica, se formula en una pasta de color gris claro fácilmente con llana. Ultrabond Eco V4 conductiva no es inflamable con muy baja emisión de compuestos orgánicos volátiles (EMICODE EC1), lo que es abso-lutamente inofensivo para el salud del instalador como para el usuario final. Por lo tanto, puede al-macenarse sin precauciones especiales. Ultrabond Eco V4 conductiva tiene una alta adhesión inicial y después de un tiempo de espera varía de 0 que los 10 minutos (A + 23 ° C) está listo para la insta-lación de cualquier tipo de suelo de PVC, siempre que el sustrato es absorbente. el máximo tiempo abierto es de aproximadamente 15 minutos a + 23 ° C. Una vez seco, después de aproximadamente 24 a 48 horas, el Ultrabond Eco V4 película conductora es flexible y Totalmente de bonos con una buena cohesión. RECOMENDACIONES • Para instalar el suelo conductor que no permite de transmisión de vapor en superficies no absorbentes utilizar Adesilex G19 conductora o Adesilex VZ Conductora. • No uti-lizar a temperaturas por debajo de + 15 ° C o por encima 35 ° C (seguir el revestimiento de suelo fa-bricante instrucciones de instalación). • No utilizar sobre soportes sujetos a la humedad ascendente.

MODO DE APLICACIÓN • Preparación del soporte El soporte debe estar uniformemente seco, absorbente, plana, sonido, mecánicamente fuerte, libre de polvo, suelta partículas, pintura, cera, aceites, óxido, residuos de yeso o cualquier Otros materiales que pueden interfiere con la unión, y ser libre de grietas. Controlar la humedad en todo el espesor del sustrato con un higrómetro de car-buro o eléctrico, Teniendo en cuenta que éste último proporciona aproximado los valores

El contenido de humedad debe ser como sigue: un máximo del 2,5 al 3% para cementos o sustratos y 0,5% para el yeso o anhidrita sustratos basados. Es esencial asegurarse de que el aumento húmedo está presente. solado sin unir arrasar más ligero hormigón, o sobre capas de aislamiento y Reglón Laid directamente sobre la tierra debe ser Llevada a cabo a través de una barrera de vapor a preven-tivo la humedad ascendente. Sus reparar grietas en el sustrato, Consolidar Reglón, formar solado de secado rápido y el nivel soportes irregulares, se recomienda Consulte la sección en el catálogo Mapei En cuanto a la preparación de los sustratos o en contacto con el Departamento Técnico Asesor

AclimataciónAntes de la instalación, asegúrese de que el suelo, el adhesivo y el sustrato son aclimatado a la re-comendada temperatura. Varias horas antes de la instalación del piso, el recubrimiento debe ser re-movido de su envoltura y desenrollado, o al menos aflojado, para aclimatarse y Reducir las tensiones causada por el embalaje.

Contacto de tierra equipotencialContacto de tierra equipotencial (puesta a tierra) En caso debe hacerse en consonancia con el Regla-mento (CEI, DIN, Amso, NFPA, ANSI, etc.). propagación la Ultrabond Eco V4 conductores con una llana fina con muescas para unir las tiras de cobre (0:08 a doce y diez mm de espesor y de 10 a 25 mm de ancho) de la rejilla conductora al sustrato. Probar la conductividad de la red antes de instalar el piso

Aplicación del adhesivo Se agita la Ultrabond Eco V4 conductiva en el fondo de la cubeta, con el fin de lograr una distribución homogénea de la conductora fibras. A continuación, haga clic en aplicarla de manera uniforme sobre el sustrato con una llana dentada en cantidad suficiente como para mojar la parte posterior del piso completo. El tiempo de espera varía de 0 a 10 minutos a aprox. + 23 ° C, dependiendo de la absorben-cia del sustrato y temperatura ambiental y la humedad.

Instalación de la cubierta del pisoSiga instalación del fabricanteInstruccionesUna vez transcurrido el tiempo de espera, el suelo debe estar instalado en el abierto tiempo del ad-hesivo, es decir, máximo 15 minutos, dependiendo del tipo de sustrato y la temperatura ambiente y la humedad. Presione la superficie de suelo inmediatamente con una paleta de madera (o similar) o rodillo del centro hacia los bordes con el fin de garantizar transferencia total del adhesivo y del aire con burbujas. suelos deformados, pueden necesitar más presion.

LISTO PARA SU USO •El suelo se establece en el tráfico peatonal ligero en varios horas, depen-diendo de la temperatura, la absorbencia del sustrato, y la porosidad del suelo. occure configuración completa después aprox. 24 a 48 horas.

LIMPIEZA • Mientras aún esté húmedo, Ultrabond Eco V4 Conductora puede ser retirado de suelos, herramientas, las manos y la ropa con agua. una vez Secar se puede quitar con alcohol o con Pulicol.

CONSUMO •El consumo varía de acuerdo con el La uniformidad del sustrato y la parte posterior de el revestimiento de suelo: aprox. 0,3 a 0,4 kg / m2.

ENVASADO • Ultrabond Eco V4 conductiva está disponible en 16 cubos kg.

ALMACENAMIENTO •Proteger de las heladas durante el transporte y almacenamiento. Evitar la exposición prolongada a temperaturas por debajo de 0 ° C. En condiciones normales Ultrabond Eco V4 Conductiva es estable durante al menos 24 meses en su embalaje original sellado.

INSTRUCCIONES DE SEGURIDAD PARA LA PREPARACIÓN Y APLICACIÓN •Ultrabond Eco V4 no es conductiva peligrosos de acuerdo con el Reglamento normas sobre la clasificación de las mezclas. es se recomienda tomar las precauciones habituales para la manipulación de productos químicos. La Hoja de Datos de Seguridad está disponible bajo petición. PRODUCTO DE USO PROFESIONAL

Ficha de datos de seguridad ULTRABOND ECO V4 SP CONDUCTIVO

Ficha de seguridad del 16/5/2015, versión 1 SECCIÓN 1: Identificación de la sustancia o la mezcla y de la sociedad o empresa

1.1. Identificador de Producto Nombre comercial: ULTRABOND ECO V4 SP CONDUCTIVE

1.2. Usos pertinentes identificados de la sustancia o de la mezcla y usos desaconsejados Uso recomen-dado: Adhesivo a base de polímero sintético a base de agua Usos desaconsejados: ==

1.3. Datos del proveedor de la ficha de datos de seguridad Proveedor: MAPEI SpA -Via Cafiero 22 - Mi-lán -ITALIA Responsable de la ficha de datos de seguridad: [email protected]

1.4. número telefónico de emergencia MAPEI SpA - Tel. + (39) 02376731 - (Horario de oficina) Poison Center - Ospedale di Niguarda - Milán - Tel. +39/02/66101029

SECCIÓN 2: Identificación de los peligros

2.1. clasificación de la sustancia o mezcla Efectos fisicoquímicos, de la salud humana y del medio am-biente adversos: No hay otros peligros

2.2. Elementos de la etiqueta Símbolos: Ninguna Declaraciones de peligro: Ninguna Consejos de pru-dencia: Ninguna Provisiones especiales: EUH210 Ficha de datos de seguridad disponible a petición. Contenido: 1,2-benzisotiazol-3 (2H) -ona: Puede producir una reacción alérgica. El producto no está clasificado como peligroso de acuerdo con el Reglamento CE 1272/2008 (CLP). Disposiciones espe-ciales de conformidad con el anexo XVII de REACH y enmiendas posteriores: Restringido a usuarios profesionales.

2.3. Otros peligros VPvB Substancias: Ninguna - Sustancias PBT: Ninguna

Ficha de datos de seguridad ULTRABOND ECO V4 SP CONDUCTIVO

Otros peligros: No hay otros peligros La sílice cristalina mencionada a continuación, que originalmente tiene la forma de polvo inhalable con límites de exposición específicos, después de su mezcla en la preparación no implica ningún ries-go de exposición.

SECCIÓN 3: Composición / información sobre los componentes

3.1. Sustancias N / A

3.2. Mezclas

Componentes peligrosos en el sentido del Reglamento CLP y clasificación correspondiente: > = 10% - <20% de sílice cristalina libre (Ø> 10 μ) CAS: 14808-60-7, CE: 238-878-4 El producto no está clasificado como peligroso de acuerdo con el Reglamento CE 1272/2008 (CLP).

> = 5% - <10% de sílice cristalina libre (Ø <10 μ) (*) CAS: 14808-60-7, CE: 238-878-4 3,9 / 2 STOT RE 2 H373

81 ppm de 1,2 - bencisotiazol - 3 (2H) - ona; 1,2 - bencisotiazolin - 3 - ona Número de índice: 613-088-00-6, CAS: 2634-33-5, CE: 220-120-9

3.2 / 2 Piel Irrit. 2 H315 3.3 / 1 Presa del ojo. 1 H318 3.4.2 / 1-1A-1B Skin Sens. 1,1A, 1B H317 4.1 / A1 Aquatic Acute 1 H400 3.1 / 4 / Toxicidad aguda oral. 4 H302

SECCIÓN 4: Medidas de Primeros Auxilios

4.1. Descripción de las medidas de primeros auxilios En caso de contacto con la piel: Lavar con abundante agua y jabón. En caso de contacto con los ojos: En caso de contacto con los ojos, lávense inmediata y abundantemente con agua y acúdase a un mé-dico. Lavar inmediatamente con agua durante al menos 10 minutos.En caso de ingestión: Puede administrarse una suspensión de carbón activado en agua, o jalea de petróleo. Lave bien la boca y beba mucha agua. En caso de enfermedad consultar a un médico Inmediatamente y presente esta hoja de datos de se-guridad. En caso de inhalación: Retirar la víctima al aire fresco y mantenerla caliente y en reposo.

4.2. Síntomas y efectos más importantes, tanto agudos como retardados No se producen peligros específicos bajo el uso normal del producto. 4.3. Indicación de cualquier atención médica inmediata y tratamiento especial necesario Tratamiento: (Véase el párrafo 4.1)

SECCIÓN 5: Medidas de lucha contra incendios 5.1. Medios de extinción Medios de extinción adecuados:

Ficha de datos de seguridad ULTRABOND ECO V4 SP CONDUCTIVO

Ninguno en particular. Medios de extinción que no deben utilizarse por razones de seguridad: Ninguno en particular.

5.2. Peligros específicos derivados de la sustancia o la mezcla El producto no presenta riesgo de incendio No inhalar los gases de la explosión y de la combustión.Los ingredientes originales o compuestos tóxicos y / o irritantes no identificados pueden estar presen-tes Combustión.

5.3. Consejos para bomberos Use un aparato respiratorio adecuado. Recoger el agua contaminada de extinción de incendios por separado. Esto no debe ser descargado en DesagüesMueva los recipientes no dañados de la zona de peligro inmediata si puede hacerse con seguridad.

SECCIÓN 6: Medidas de Liberación accidental

6.1. Precauciones personales, equipo de protección y procedimientos de emergencia Use equipo de protección personal. Saque las personas a salvo. Véanse las medidas de protección previstas en los puntos 7 y 8.

6.2. precauciones ambientales Limitar las fugas con tierra o arena. No permita que entre en el suelo / subsuelo. No permita que entre en el agua superficial o en los desagües. Conserve el agua de lavado contaminada y deséchela. En caso de escape de gas o de entrada en cursos de agua, suelo o desagües, informar al responsable autoridades. Material adecuado para absorber: material absorbente, orgáni-co, arena

6.3. Métodos y material de contención y limpieza Material adecuado para absorber: material absor-bente, orgánico, arena Lavar con abundante agua. Conserve el agua de lavado contaminada y de-séchela.

6.4. Referencia a otras secciones Véase también las secciones 8 y 13

SECCIÓN 7: Manipulación y almacenamiento

7.1. Precauciones para una manipulación segura

Evite el contacto con la piel y los ojos, inhalación de vapores y nieblas. No coma ni beba mientras trabaja.Véase también la sección 8 para el equipo de protección recomendado. El polvo fino puede formar una mezcla explosiva con el aire. Mantener alejado de llamas, calor y chispas.No retire la película retráctil en lugares peligrosos (debido al riesgo de carga / descarga estática)

7.2. Condiciones para almacenaje seguro, incluyendo cualquier incompatibilidad

Mantener alejado de alimentos, bebidas y piensos. Materiales incompatibles:Ninguno en particular.Instrucciones relativas a los locales de almacenamiento: Locales adecuadamente ventilados. Conservar por encima de 5 ° C.

7.3. Uso (s) final (es) específico (s)Ninguno en particular

SECCIÓN 8: Controles de la exposición / protección personal

8.1. Parámetros de control Sílice cristalina libre (Ø> 10 μ) - CAS: 14808-60-7 ACGIH - LTE mg / m3 (8h): 0.025 mg / m3 - Notas: A2 (R) - Pulm fibrosis, cáncer de pulmón

Ficha de datos de seguridad ULTRABOND ECO V4 SP CONDUCTIVO

Sílice cristalina libre (Ø <10 μ) (*) - CAS: 14808-60-7 EU - LTE mg / m3 (8h): 0.025 mg / m3 - Notas: A2 (R) - Pulm fibrosis, cáncer de pulmón ACGIH - LTE mg / m3 (8h): 0,025 mg / m3 - Notas: A2 (R) - Fibrosis pulmonar, cáncer de pulmón

Valores límite de exposición DNEL N / A Valores límite de exposición PNEC N / A

8.2. Controles de expocicion Protección para los ojos: No es necesario para el uso normal. De todos modos, operar de acuerdo a buenas prácticas de trabajo. Protección de la piel: No se debe adoptar ninguna precaución especial para el uso normal. Protección para manos: No es necesario para el uso normal. Protección respiratoria: No es necesario para el uso normal.

En caso de ventilación insuficiente use máscara con filtros de tipo B (EN 14387). El equipo de protec-ción personal debe cumplir con las normas CE pertinentes (como EN 374 para guantes y EN 166 para gafas), correctamente conservadas y almacenadas. Consulte al proveedor para comprobar la Equipo contra productos químicos específicos y para la información del usuario. Peligros Térmicos: Ninguna Controles de exposición ambiental: NingunaEl equipo de protección personal debe cumplir con las normas CE pertinentes (como EN 374 para guantes y EN 166 para gafas), correctamente conservadas y almacenadas. Consulte al proveedor para comprobar la Equipo contra productos químicos específicos y para la información del usuario.

Peligros Térmicos: Ninguna Controles de exposición ambiental: Ninguna

SECCIÓN 9: Propiedades físicas y químicas

9.1. Información sobre propiedades físicas y químicas básicas Apariencia: pegar Color: gris Olor: típico Umbral de olor: N / A PH: 7,5 Punto de fusión / punto de congelación: N / A Punto inicial de ebullición y rango de ebullición: 100 ° C Sólido / inflamabilidad de gas: N / ALímites superior / inferior de inflamabilidad o de explosión: N / ADensidad de vapor: N / APunto de inflamabilidad: ° C Tasa de evaporación: N / A Presión de vapor: N / A Densidad relativa: 1,10-1,15 g / cm $ ³ $ (23 ° C) Densidad de vapor (aire = 1): N / A Solubilidad en agua: Dispersable Solubilidad en aceite: insoluble Viscosidad: 400000 - 480000 mPa.s (23 ° C) Temperatura de ignición espontánea: ° C Límites de explosión (en volumen): == Temperatura de descomposición: N / A Coeficiente de reparto (n-octanol / agua): N / A Propiedades explosivas: == Propiedades comburentes: N / A

9.2. Otra información

Ficha de datos de seguridad ULTRABOND ECO V4 SP CONDUCTIVO

Miscibilidad: N / A Solubilidad en grasa: N / A Conductividad: N / APropiedades relevantes de los Grupos de Sustancias N /A

SECCIÓN 10: Estabilidad y reactividad

10.1. Reactividad Estable en condiciones normales 10.2. Estabilidad químicaEstable en condiciones normales 10.3. Posibilidad de reacciones peligrosasNinguna 10.4. Condiciones para evitarEstable en condiciones normales.10.5. materiales incompatibles Ninguno en particular. 10.6. productos de descomposición peligrosos Ninguna.

SECCIÓN 11: Información toxicológica

11.1. Información sobre los efectos toxicológicos Las vías de entrada: Ingestión: Sí Inhalación: No Contacto: No Información toxicológica relacionada con el producto: No hay datos toxicológicos disponibles sobre la mezcla. Considere la concentración individual de cada uno Componente para evaluar los efectos toxicológicos resultantes de la exposición a la mezcla. Información toxicológica de la mezcla: N / AInformación toxicológica de las principales sustancias presentes en la mezcla: 1,2 - bencisotiazol - 3 (2H) - ona; 1,2 - bencisotiazolin - 3 - ona - CAS: 2634 - 33 - 5 A) toxicidad aguda: Prueba: LD50 - Ruta: Oral - Especies: Ratón> 1150 mg / kgPrueba: LD50 - Ruta: Piel - Especies: Ratón> 2000 mg / kg Prueba: LD50 - Ruta: Oral - Especies: Rata> 597 mg / kg Propiedades Corrosivas / Irritantes: Ojo: El producto puede causar una irritación temporal por contacto. Propiedades de sensibilización: No se conocen efectos. Efectos cancerígenos: No se conocen efectos. Efectos mutagénicos: No se conocen efectos. Efectos Teratogénicos: No se conocen efectos. Si no se especifica de manera diferente, la información requerida en la Regla 453/2010 / CE Considerado como NA: A) toxicidad aguda B) corrosión / irritación de la piel C) daño / irritación ocular graveD) sensibilización respiratoria o cutánea

Ficha de datos de seguridad ULTRABOND ECO V4 SP CONDUCTIVO

E) mutagenicidad de las células germinales F) carcinogenicidad G) toxicidad reproductivaH) STOT - exposición única I) STOT-exposición repetida J) peligro de aspiración

SECCIÓN 12: Información ecológica

12.1. Toxicidad Adoptar buenas prácticas industriales, para que el producto no sea liberado al medio ambiente.Datos no disponibles sobre la mezcla Toxicidad acuática: la preparación no debe considerarse tóxica para el medio ambiente acuático En los componentes. LC50> 100mg / l - especies acuáticas (datos calculados según la Directiva 1999/45 / CE).Biodegradabilidad: no es fácilmente biodegradableBiodegradabilidad: no se dispone de datos sobre la preparación. 1,2 - bencisotiazol - 3 (2H) - ona; 1,2 - bencisotiazolin - 3 - ona - CAS: 2634 - 33 - 5 A) Toxicidad aguda acuática: Punto final: EC50 - Especies: Daphnia = 3,7 mg / l - Duración h: 48 Punto final: EC50 - Especies: Algas = 0.37 mg / l - Duración h: 72

12.2. Persistencia y degradabilidad N / A 12.3. potencial bioacumulativo N / A 12.4. Movilidad en el suelo N / A 12.5. Resultados de la evaluación PBT y mPmB Lista de sustancias peligrosas para el medio ambiente y clasificación correspondiente: 81 ppm de 1,2 - bencisotiazol - 3 (2H) - ona; 1,2 - bencisotiazolin - 3 - ona CAS: 2634-33-5 R50 Muy tóxico para los organismos acuáticos. EC50 (Daphnia): 3,7 mg / l (48 h) EC50 (Algas): 0,37 mg / l (72 h) 40 ppm 2 - metil - 2H - isotiazol - 3 - ona (MIT) CAS: 2682-20-4 R50 Muy tóxico para los organismos acuáticos. 696 ppb masa de reacción de: 5-cloro-2-metil-4-isotiazolin-3-ona [CE nº. 247 - 500 - 7]; y 2 - metil - 2H - isotiazol - 3 - ona [CE Nº. 220 - 239 - 6] (3: 1); Masa de reacción de: 5 - cloro - 2 - metil - 4 - isotiazolin - 3 - ona [CE Nº. 247 - 500 - 7]; Y 2 - metil - 4 - isotiazolin - 3 - ona [CE

CAS: 55965-84-9 R50 / 53 Muy tóxico para los organismos acuáticos, puede provocar a largo plazo efectos ambiente acuático. EC50 (Daphnia): 0,16 mg / l (48 h) CL _ {50} (Pescado): 0,19 mg / l (96 h) VPvB Substancias: Ninguna - Sustancias PBT: Ninguna

12.6. Otros efectos adversos Datos no disponibles sobre la mezcla

SECCIÓN 13: Consideraciones sobre la eliminación

13.1. Métodos de tratamiento de residuos Recupere si es posible. Al hacerlo, cumplir con las regulaciones locales y nacionales vigentes.

Ficha de datos de seguridad ULTRABOND ECO V4 SP CONDUCTIVO

91/156 / CEE, 91/689 / CEE, 94/62 / CE y enmiendas posteriores. Eliminación del producto endurecido (código de residuos CE): 08 04 10Eliminación del producto no endurecido (código de residuos CE): 08 04 14El código de residuos europeo propuesto se basa únicamente en la composición del producto. De acuerdo con el proceso o campo de aplicación específico, puede ser necesario un código de dese-cho diferente.

SECCIÓN 14: Información sobre el transporte

14.1. un numero No clasificado como peligroso en el sentido de las regulaciones de transporte. Un numero: == 14.2. Nombre de transporte propio de la ONU N / A 14.3. Clase (s) de peligro para el transporte Ferrocarril / Carretera (RID / ADR): Ningún bien peligroso ADR-Número superior: N / A Aire (ICAO / IATA): Ningún bien peligrosoMar (IMO / IMDG): Ningún bien peligroso N / A 14.4. Grupo de embalaje N / A 14.5. Peligros ambientales Contaminante marino: No N / A 14.6. Precauciones especiales para el usuario N / A 14.7. Transporte a granel de acuerdo con el Anexo II de MARPOL73 / 78 y el Código IBC N / A No

SECCIÓN 15: Información reglamentaria

15.1. Reglamentación y legislación en materia de seguridad, salud y medio ambiente específicas para la sustancia o la mezcla Dir 98/24 / CE (Riesgos relacionados con los agentes químicos en el trabajo) Dir 2000/39 / CE (Valores límite de exposición profesional) Dir 2006/8 / CE El Reglamento (CE) n. 1907/2006 (REACH) El Reglamento (CE) n. 1272/2008 (CLP) El Reglamento (CE) n. 790/2009 (ATP 1 CLP) y (UE) n. 758/2013 Reglamento (UE) n. 453/2010 (Anexo I) Reglamento (UE) n. 286/2011 (ATP 2 CLP) Reglamento (UE) n. 618/2012 (ATP 3 CLP) Reglamento (UE) n. 487/2013 (ATP 4 CLP) Reglamento (UE) n. 944/2013 (ATP 5 CLP)

Restricciones relativas al producto oa las sustancias contenidas en el anexo XVII Reglamento (CE) 1907/2006 (REACH) y modificaciones posteriores: Restricciones relacionadas con el producto: Sin restricción. Restricciones relativas a las sustancias contenidas: Restricción 28 Reglamento REACH (1907/2006) - Todos. XVII: NA Decreto Legislativo no. 81 del 9 de abril de 2008 Título XI “Sustancias peligrosas - Capítulo I - Protección contra agentes químicos “ Directiva 2000/39 / CE y smi (límite de umbral profesional) Decreto Legislativo no. 152 del 3 de abril de 2006 y modificaciones y adiciones posteriores. (Regulaciones ambientales) Directiva 105/2003 / CE (Seveso III): NA

Ficha de datos de seguridad ULTRABOND ECO V4 SP CONDUCTIVO

Acuerdo ADR - Código IMDG - Reglamento de la IATA GEV-EMICODE: CE 1 (emisiones muy bajas) Wassergefärdungsklasse (WGK): 1 VOC (2004/42 / CE): NA g / l 15.2. Evaluación de seguridad química No

SECCIÓN 16: Otra información

Texto de las frases mencionadas en la rúbrica 3: H373 Puede causar daño a los órganos tras exposiciones prolongadas o repetidas por inhalación. H315 Provoca irritación de la piel. H318 Provoca lesiones oculares graves. H317 Puede provocar una reacción alérgica en la piel. H400 Muy tóxico para los organismos acuáticos. H302 Nocivo por ingestión. Esta ficha de datos de seguridad se ha actualizado completamente de conformidad con el Reglamen-to 453/2010 / UE. Este documento fue preparado por una persona competente que ha recibido la capacitación adecuada. Principales fuentes bibliográficas: NIOSH - Registro de efectos tóxicos de sustancias químicas ECDIN - Red de Datos e Información sobre Productos Químicos Ambientales - Centro Común de In-vestigación, Comisión de las Comunidades Europeas SAX’S - Propiedades peligrosas de los materiales industriales Istituto Superiore di Sanità - Inventario Nazionale Sostanze Chimiche La información aquí contenida se basa en nuestro estado de conocimiento en la fecha especificada anteriormente.Se refiere únicamente al producto indicado y no constituye garantía alguna de calidad particular. Es deber del usuario asegurarse de que esta información es apropiada y completa con respecto a la Uso específico previsto. Esta MSDS anula y reemplaza cualquier versión anterior.

ADR: Acuerdo europeo relativo al transporte internacional de Mercancías Peligrosas por Carretera. CAS: Chemical Abstracts Service (división de la Chemical Sociedad). CLP: Clasificación, Etiquetado, Embalaje. DNEL: Nivel sin efecto derivado. EINECS: Inventario Europeo de Sustancias Químicas Comerciales Existentes. GefStoffVO: Ordenanza sobre Sustancias Peligrosas, Alemania. GHS: Sistema Mundialmente Armonizado de Clasificación y Etiquetado de Productos químicos.

Ficha de datos de seguridad ULTRABOND ECO V4 SP CONDUCTIVO

IATA: Asociación Internacional de Transporte Aéreo. IATA-DGR: De Mercancías Peligrosas por el “Servicio de Transporte Aéreo Asociación “(IATA). OACI: Organización de Aviación Civil Internacional. ICAO-TI: Instrucciones Técnicas de la “Organización de Aviación Civil Internacional” (OACI). IMDG: Código Marítimo Internacional de Mercancías Peligrosas. INCI: Nomenclatura Internacional de Ingredientes Cosméticos. KSt: Coeficiente de explosión. CL50: Concentración letal, para el 50 por ciento de la población de prueba. LD _ {50}: Dosis letal, para el 50 por ciento de la población de prueba. LTE: Exposición a largo plazo.PNEC: Concentración predicha sin efecto. ELIMINAR: Reglamento relativo al transporte internacional de mercancías peligrosas por ferrocarril. STE: Exposición a corto plazo. STEL: Límite de exposición a corto plazo.STOT: Toxicidad específica para órganos diana. TLV: Valor Umbral de Limitación. TWATLV: Valor límite del umbral para el promedio ponderado en el tiempo de 8 horas al día. (Norma ACGIH). OEL: Valor límite umbral europeo VLE: Valor Umbral de Limitación. WGK: Clase de peligro de agua alemana. TSCA: Inventario de la Ley de Control de Sustancias Tóxicas de los Estados Unidos DSL: DSL - Lista canadiense de sustancias domésticas

2 Environmental Product Declaration FEICA – Dispersion-based products, Class A

1. General Information

FEICA - Association of the European Adhesive and Sealant Industry

Dispersion-based products,Class A

Programme holderIBU - Institut Bauen und Umwelt e.V.Panoramastr. 110178 BerlinGermany

Owner of the DeclarationFEICA - Association of the European Adhesive and Sealant Industry Avenue E. van Nieuwenhuyse 41160 Brussels Belgium

Declaration numberEPD-FEI-20160084-IBG1-EN

Declared product / Declared unit1 kg with a density 1,000 - 1,500 kg/m³

This Declaration is based on the Product Category Rules:Coatings with organic binders, 07.2014 (PCR tested and approved by the SVR)

Issue date29/08/2016

Valid to28/08/2021

Scope:This validated Declaration entitles the holder to bear the symbol of the Institut Bauen und Umwelt e.V. It exclusively applies for products produced in Europe and for a period of five years from the date of issue. This EPD may be used by FEICA members and their members provided it has been proven that the respective product can be represented by this EPD. For this purpose a guideline is available at the FEICA secretariat. The members of FEICA are listed on its website. The owner of the declaration shall be liable for the underlying information and evidence; the IBU shall not be liable with respect to manufacturer information, life cycle assessment data and evidences.Verification

The CEN Norm /EN 15804/ serves as the core PCRIndependent verification of the declaration

according to /ISO 14025/Prof. Dr.-Ing. Horst J. Bossenmayer(President of Institut Bauen und Umwelt e.V.) internally x externally

Dr. Burkhart Lehmann(Managing Director IBU)

Mr Olivier Muller(Independent verifier appointed by SVR)

2. Product

2.1 Product descriptionDispersion-based products comprise organic binding agents based on synthetic and/or natural resins, mineral fillers such as chalk as well as water and smaller volumes of auxiliaries (thickening agents, defoaming agents, surface-active agents, preservatives etc.). They dry physically through evaporation of the water contained therein.They comply with manifold, often specific, tasks in the construction, furnishing and repair of buildings. Using dispersion-based products decisively improves the fitness for use of structures and extends their life expectancy.The product displaying the highest environmental impacts within the class of dispersion-based products considered was used as a representative product for calculating the Life Cycle Assessment results (worst case-approach).

2.2 ApplicationDispersion-based products are used for the following applications:Module 1: Dispersion adhesives, fixatives, pre-coatings and primers for floor coverings and parquet

flooring Adhesives for, e.g.- tufted carpets with various backing- woven textile coverings, fibre-bonded and natural-fibre coverings- resilient coverings (PVC, rubber)- linoleum- insulating bases and underlays- parquet, laminate and wood blocks on surfaces ready for laying. The products are suitable for normal wear in residential and commercial areas, also on heated floor constructions. Module 2: Dispersion-based tile adhesiveProducts for bonding ceramic tiles and paving as well as natural stone for internal and external installations on walls, floors and ceilings Module 3: Dispersion-based adhesives, coatings and sealantsAs structural adhesives, coatings and sealants:· structural and repair adhesives· dispersion filler compounds· joint sealantsModule 4: Dispersion-based products for waterproofing of buildings

3 Environmental Product Declaration FEICA – Dispersion-based products, Class A

Module 5: Dispersion-based primers and bonding agents for concrete and floor screeds Module 6: Dispersion-based products for surface protection of concreteTo increase the durability of concrete and reinforced steel structures as well as for new concrete and for maintenance and repair work (for areas without vehicle traffic) Module 7: Dispersion-based primers, barrier coatings, varnishes and glazes for coating of buildings, structural elements and components for decorative, functional or protective purposes

2.3 Technical DataModule 1: Dispersion adhesives, fixatives, pre-coatings and primers for floor coverings and parquet flooringDispersion adhesives for floor coverings have to comply with the requirements of the /EN 14259:2003/. Fixatives do not usually comply with these requirements; their strengths are lower in accordance with their specifications. The performance characteristics of pre-coatings and primers are subject to the manufacturer's technical documentation / declaration of performance. Dispersion adhesives for parquet: The test procedures and requirements of the /EN 14293:2006/ have to be fullfilled. Module 2: Dispersion-based tile adhesiveThe minimum requirements in accordance with /EN 12004:2012/ must be maintained. These are:- Shear adhesion strength after dry storage (/EN 1324:2007/)- Shear adhesion strength after heat ageing (/EN 1324:2007/)- Open time: tensile adhesion strength (/EN 1346:2007/)Other performance characteristics in accordance with the manufacturer's technical documentation / declaration of performanceModule 3: Dispersion-based adhesives, coatings and sealants Performance characteristics in accordance with the manufacturer's technical documentation / declaration of performance Module 4: Dispersion-based products for waterproofing of buildingsThe minimum requirements of the /ETAG 022:2007/ apply. The performance characteristics must be indicated in accordance with the European Technical Assessment (ETA, no.). Module 5: Dispersion-based primers and bonding agents for concrete and floor screedsPerformance characteristics in accordance with the manufacturer's technical documentation / declaration of performance Module 6: Dispersion-based products for surface protection of concreteDispersion-based products for surface protection systems of concrete comply with the following requirements (characteristics for all intended uses in accordance with /EN 1504-2:2005/, Tables 1 and 5): - Permeability to CO2 (/EN 1062-6:2002/)- Water vapour permeability (/EN ISO 7783-1/-2:2012/)- Capillary absorption and permeability to water (/EN 1062-3:2008/)- Measurement of bond strength by pull-off (/EN 1542:1999/)

Other performance characteristics in accordance with the manufacturer's technical documentation / declaration of performance Module 7: Dispersion-based primers, barrier coatings, varnishes and glazes for coating of buildings, structural elements and components for decorative, functional or protective purposesThe requirements of the /Decopaint Directive 2004/42/EC/ apply• for unpigmented primers• for pigmented dispersion varnishes and dispersion primers in Decopaint product group d• for water-soluble glazes in Decopaint product groups e or f• for barrier primers in Decopaint product group g• for single-component special varnishes in Decopaint product group i,all of which are water-based.Performance characteristics in accordance with the manufacturer's technical documentation / declaration of performance. 2.4 Placing on the market / Application rulesFor the placing on the market in the EU/EFTA (with the exception of Switzerland) products falling under the Regulation /(EU) No 305/2011/ need a Declaration of Performance taking into consideration either the relevant harmonised European standard or the European Technical Assessment as cited in chapter 2.3 and the CE-marking. For the application and use of the products the respective national provisions apply.

2.5 Delivery statusLiquid or pasty in containers made of plastic or metal. Typical container sizes contain 1 to 30 kg, usually 10 to 20 kg of product on pallets. For larger applications, vats with approx. volumes of 200 kg (litres) or IBCs (intermediate bulk containers) with a capacity in excess of 1 tonne (m³) are also used. A plastic container was modelled for the Life Cycle Assessment.

2.6 Base materials / Ancillary materials Dispersion-based products usually comprise at least one synthetic resin dispersion, natural or synthetic resins dispersed in water, mineral fillers (e.g. chalk) and/or pigments. Auxiliaries such as thickening agents, defoaming agents, surface-active and dispersing agents as well as preservatives are used to fine-tune the product features.On average, the products covered by this EPD contain the following range of base materials and auxiliaries (% by mass):- Synthetic resin dispersion (solids portion): 5 - 65- Natural resins, natural resin derivatives: 0 - 25- Mineral fillers: 0 - 60- Pigments: 0 - 35- Water: 15 - 95- Auxiliaries: 1 - 5- Thickening agents: < 3- Dispersing agents / Emulsifying agents: < 2- Wetting agent: 2- Other: 0 - 2 The biocidal products used contain agents which can be marketed in accordance with Biocidal Products Regulation /(EU) No 528/2012/.In individual cases, it is possible that substances on the list of particularly harmful substances for inclusion in Annex XIV of the /REACH/ regulation are contained in concentrations of exceeding 0.1%. If this is the case,

4 Environmental Product Declaration FEICA – Dispersion-based products, Class A

this information can be found on the respective safety data sheet.

2.7 ManufactureDispersion-based products are usually mixed discontinuously in batch mode, i.e. in individual batches or series of individual batches, and filled into the delivery containers. The quality of the products and safe handling thereof is ensured by the corresponding regulations such as /ISO 9001:2008-12/ and the provisions outlined in the relevant regulations such as the Industrial Safety Regulation and Federal Pollution Control Act.

2.8 Environment and health during manufacturing

As a general rule, no particular environmental or health protection measures other than those specified by law are necessary.

2.9 Product processing/InstallationDispersion-based products are processed on site using suitable tools, usually by hand. The products are applied by trowelling/knife-coating, painting, rolling or spraying, whereby health and safety measures (gloves and goggles, ventilation) are to be taken and consistently adhered to in accordance with the information on the safety data sheet and conditions on site.Depending on the application and product specifications, between 50 and 1,500 g/m² are applied.

2.10 PackagingA detailed description of packaging is provided in section 2.5. Empty containers and clean foils can be recycled.

2.11 Condition of useDuring the use phase dispersion-based products are existent as hardened film.They are long-lasting products which protect our buildings in the form of primers, coatings or sealants as well as making an essential contribution towards their appearance, function and sustainability.

2.12 Environment and health during useOption 1 – Products for applications outside indoor areas with permanent stays by peopleNo risks are known for water, air and soil if the products are used as designated.Option 2 – Products for applications inside indoor areas with permanent stays by people When used in indoor areas with permanent stays by people, evidence of the emission performance of construction products in contact with indoor air must be submitted according to national requirements. No further influences on the environment and health by emanating substances are known.

2.13 Reference service lifeDispersion-based products fulfil manifold, often specific, tasks in the construction, refurbishment or renovation of building structures. They decisively improve the usability of building structures and significantly extend their original service lives.

The anticipated reference service life depends on the specific installation situation and the exposure associated with the product. It can be influenced by weather factors as well as by mechanical or chemical loads.

2.14 Extraordinary effects

FireIn terms of their application volumes, dispersion-bound products usually have no or only a subordinate influence on the fire characteristics of the structure in which they have been used.

WaterDispersion-based products are only water-resistant to a certain degree and their strength can deteriorate when exposed to water for longer periods of time, detaching from the surface in a worst-case scenario. The primary components of dispersion-based products are not hazardous to water or only slightly hazardous to water. Owing to the overall low volumes of dispersion-based products used on buildings, no relevant contribution towards environmental damage can be anticipated by buildings featuring dispersion-based products in the event of extraordinary exposure to water.

Mechanical destructionThe mechanical destruction of dispersion-bound products does not lead to any decomposition products which are harmful for the environment or health.

2.15 Re-use phaseAccording to present knowledge, no known environmentally-hazardous effects in terms of disposal are to be generally anticipated through dismantling and recycling components to which hardened, dispersion-bound products adhere.

2.16 DisposalThe portion of a dispersion-based product applied at an other construction product is rather low. These low amounts do not play any role when the construction product is disposed. They do not interfere with the disposal/recycling of other components / building materials.Hardened product residue mechanically removed from substrates must be disposed of as commercial / construction waste.The following waste codes according to the European List of Waste (/2000/532/EC/) can apply: Hardened product residue: 08 01 12 waste paint and varnish other than those mentioned in 08 01 1108 04 10 waste adhesives and sealants other than those mentioned in 08 04 09

2.17 Further informationMore information is available in the manufacturer's product or safety data sheets and is available on the manufacturer's websites or on request. Valuable technical information is also available on the associations's websites.

3. LCA: Calculation rules

5 Environmental Product Declaration FEICA – Dispersion-based products, Class A

3.1 Declared UnitThis EPD refers to the declared unit of 1 kg dispersion-based product with a density of 1.000 - 1.500 kg/m3 in the mixing ratio required for processing the components in accordance the PCR part B for Coatings with organic binders.Consumption per unit area of the products to be applied extensively can range between 50 - 3.000 g/m2.The results of the Life Cycle Assessment provided in this declaration have been calculated from the product with the highest environmental impact (worst-case scenario).

Declared unitName Value UnitConversion factor to 1 kg 1 -Declared unit 1 kg

3.2 System boundaryModules A1-A3, A4, A5 and D are taken into consideration in the LCA:

A1 Production of preliminary products A2 Transport to plant A3 Production (incl. provision of energy,

production of packaging as well as auxiliaries and consumables, waste treatment)

A4 Transport to site A5 Installation (disposal of packaging &

installation losses and emissions during installation)

D Credits from incineration of packaging materials & installation losses

The declaration is therefore from "cradle to gate - with options".

3.3 Estimates and assumptionsWhere no specific /GaBi/ processes were available, the individual constituent materials of the formulations were estimated based on information provided by the manufacturerer or literature sources.

3.4 Cut-off criteriaAll raw materials submitted for the formulations and production data were taken into consideration.The manufacture of machinery, plants and otherinfrastructure required for production of the productsunder review was not taken into consideration in theLCA.Transport of packaging materials is also excluded.

3.5 Background dataData from the /GaBi/ 6 database was used as background data. Where no background data was available, data gaps were complemented by manufacturer information and literature research.

3.6 Data qualityRepresentative products were selected for this EPD. The product displaying the highest environmental impacts in a group was selected for calculating the LCA results. The datasets are less than 5 years old. Data for production and packaging are based on detailsprovided by the manufacturer. The formulation used for evaluation refers to a specific product.

3.7 Period under reviewRepresentative formulations were accepted by FEICALtd and collected in 2011.

3.8 AllocationNo allocations were applied for production. A multi-input allocation with a credit for electricity and thermalenergy was used for incineration of productionresidues and packaging materials. The creditsachieved through packaging disposal are declared inModule D.

3.9 ComparabilityBasically, a comparison or an evaluation of EPD data is only possible if all the data sets to be compared were created according to /EN 15804/ and the building context, respectively the product-specific characteristics of performance, are taken into account. In this case, 1 kg dispersion-based product was selected as the declared unit. Depending on the application, a corresponding conversion factor such as the specific weight per surface area must be taken into consideration.

6 Environmental Product Declaration FEICA – Dispersion-based products, Class A

4. LCA: Scenarios and additional technical information

The following technical information is a basis for the declared modules or can be used for developing specific scenarios in the context of a building assessment if modules are not declared (MND). Transport to the building site (A4)Name Value UnitLitres of fuel 0.0016 l/100kmTransport distance 1000 kmCapacity utilisation (including empty runs) 85 %

Gross density of products transported 1000 - 1500 kg/m3

Capacity utilisation volume factor 1 -

Installation into the building (A5)Name Value UnitMaterial loss 0.01 kgVOC in the air 0.077 kg

7 Environmental Product Declaration FEICA – Dispersion-based products, Class A

5. LCA: Results

DESCRIPTION OF THE SYSTEM BOUNDARY (X = INCLUDED IN LCA; MND = MODULE NOT DECLARED)

PRODUCT STAGECONSTRUCTION PROCESS

STAGEUSE STAGE END OF LIFE STAGE

BENEFITS AND LOADS

BEYOND THE SYSTEM

BOUNDARIES

Raw

mat

eria

l su

pply

Tran

spor

t

Man

ufac

turin

g

Tran

spor

t fro

m th

e ga

te to

the

site

Ass

embl

y

Use

Mai

nten

ance

Rep

air

Rep

lace

men

t

Ref

urbi

shm

ent

Ope

ratio

nal e

nerg

y us

e

Ope

ratio

nal w

ater

us

e

De-

cons

truct

ion

dem

oliti

on

Tran

spor

t

Was

te p

roce

ssin

g

Dis

posa

l

Reu

se-

Rec

over

y-R

ecyc

ling-

pote

ntia

l

A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D

X X X X X MND MND MND MND MND MND MND MND MND MND MND X

RESULTS OF THE LCA - ENVIRONMENTAL IMPACT: 1 kg Dispersion-based product, Class AParameter Unit A1-A3 A4 A5 D

Global warming potential [kg CO2-Eq.] 2.06E+0 4.87E-2 1.60E-1 -6.90E-2Depletion potential of the stratospheric ozone layer [kg CFC11-Eq.] 1.29E-9 2.24E-13 4.99E-13 -2.28E-11

Acidification potential of land and water [kg SO2-Eq.] 2.36E-2 1.20E-4 1.69E-5 -1.10E-4Eutrophication potential [kg (PO4)3--Eq.] 9.09E-4 2.78E-5 3.47E-6 -1.11E-5

Formation potential of tropospheric ozone photochemical oxidants [kg ethene-Eq.] 1.41E-3 -3.37E-5 2.80E-2 -1.16E-5Abiotic depletion potential for non-fossil resources [kg Sb-Eq.] 2.60E-6 3.25E-9 1.53E-9 -1.18E-8

Abiotic depletion potential for fossil resources [MJ] 4.54E+1 6.71E-1 2.67E-2 -9.48E-1RESULTS OF THE LCA - RESOURCE USE: 1 kg Dispersion-based product, Class A

Parameter Unit A1-A3 A4 A5 D

Renewable primary energy as energy carrier [MJ] 4.31E+0 IND IND INDRenewable primary energy resources as material utilization [MJ] 0.00E+0 IND IND IND

Total use of renewable primary energy resources [MJ] 4.31E+0 3.82E-2 3.97E-3 -1.57E-1Non-renewable primary energy as energy carrier [MJ] 4.29E+1 IND IND IND

Non-renewable primary energy as material utilization [MJ] 6.40E+0 IND IND INDTotal use of non-renewable primary energy resources [MJ] 4.93E+1 6.74E-1 3.16E-2 -1.16E+0

Use of secondary material [kg] 0.00E+0 0.00E+0 0.00E+0 0.00E+0Use of renewable secondary fuels [MJ] 0.00E+0 0.00E+0 0.00E+0 0.00E+0

Use of non-renewable secondary fuels [MJ] 0.00E+0 0.00E+0 0.00E+0 0.00E+0Use of net fresh water [m³] 7.54E-2 9.56E-5 3.83E-4 -2.44E-4

RESULTS OF THE LCA – OUTPUT FLOWS AND WASTE CATEGORIES: 1 kg Dispersion-based product, Class A

Parameter Unit A1-A3 A4 A5 D

Hazardous waste disposed [kg] 1.56E-5 5.09E-8 5.80E-11 -4.48E-10Non-hazardous waste disposed [kg] 3.86E-1 5.66E-5 1.45E-3 -4.13E-4

Radioactive waste disposed [kg] 1.34E-3 9.63E-7 1.96E-6 -8.45E-5Components for re-use [kg] 0.00E+0 0.00E+0 0.00E+0 0.00E+0Materials for recycling [kg] 0.00E+0 0.00E+0 0.00E+0 0.00E+0

Materials for energy recovery [kg] 0.00E+0 0.00E+0 0.00E+0 0.00E+0Exported electrical energy [MJ] 0.00E+0 0.00E+0 2.42E-1 0.00E+0Exported thermal energy [MJ] 0.00E+0 0.00E+0 5.58E-1 0.00E+0

6. LCA: Interpretation

The majority of life cycle energy consumption takes place during the production phase (A1-A3). Significant contributions to Primary Energy Demand – Non-renewable (PENRT) derive from the energy resources used in the production of raw materials. The largest contributor to Primary Energy Demand – Renewable (PERT) is the consumption of renewable energy resources required for the generation and supply of electricity. During manufacturing (A1-A3) some influence also arises due to the wooden pallets used as packaging that need solar energy for photosynthesis. It should be noted that Primary Energy Demand – Renewable (PERT) generally represents a small percentage of the production phase primary energy demand with the bulk of the demand coming from non-renewable energy resources.

Transportation to the construction site (A4) and the installation process (A5) make a minor contribution to almost all impacts. The only exception is the photochemical ozone creation potential (POCP) that is significantly influenced by the installation of the product due to emissions of volatile substances of maximum 7.7%. This leads to a contribution of the installation phase of up to 95/% on the overall life cycle of the product. Emissions associated with the manufacturing of products (A3) only have a negligible influence on POCP.In module A4, transport to construction site, values for POCP are negative due to emission profile modelled for the selected transportation process and of the characterisation method used in /CML 2001/ for the calculation of the POCP. Transportation processes are responsible for the emission of NOx in the ground layer

9 Environmental Product Declaration FEICA – Dispersion-based products, Class A

The table above provides an overview of the most relevant regulations and specifications as of April 2015, as regards requirements after 28 days storage in a ventilated test chamber. Some details may be missing in the table due to lack of space. Values given represent maximum values/limits.

7.2 Leaching: Dispersion-based products in outdoor applications are not used in areas with contact to soil and groundwater. There are currently no European or national

assessment criteria or emission scenarios in place for scenarios involving watered components.

7.3 Fire gas toxicityThe fire gases incurred by organic products contain hazardous substances but no particularly hazardous emissions. Testing toxicity of the fire gases makes sense particularly in the system configuration of the products and is therefore not carried out for individual coatings as the fire gases are essentially influenced by the type of substrate involved.

8. References

PCR 2013, Part A: 2013-04Institut Bauen und Umwelt e.V., Berlin (pub.): Product Category Rule for Construction Products from the range of Environmental Product Declarations of Institut Bauen und Umwelt (IBU), Part A: Calculation rules for the Life Cycle Assessment and requirements on the Background Reportwww.bau-umwelt.de

PCR 2013, Part B: 2013-07

Product Category Rules for Construction Products, Part B: Requirements on the EPD for coatings with organic binding agents

GaBi 6 2014: Software and data base for comprehensive analysis. LBP, University of Stuttgart and thinkstep, 2014

GaBi 6 2014b:Documentation of GaBi 6 data sets from the data base

10 Environmental Product Declaration FEICA – Dispersion-based products, Class A

for comprehensive analysis LBP, University of Stuttgart and thinkstep, 2014 http://documentation.gabi-software.com/

CEN/TS 14472:2003-10 Resilient, textile and laminate floor coverings - Design, preparation and installation – Part 1: General; Part 2: Textile floor coverings; Part 3: Laminate floor coverings; Part 4: Resilient floor coverings

EN 14259:2004-07Adhesives for floor coverings – Requirements for mechanical and electrical performance

EN 14293:2006-10Adhesives – Adhesives for bonding parquet to subfloor – Test methods and minimum requirements

EN 12004:2014-02Adhesives for tiles – Requirements, evaluation of conformity, classification and designation

EN 1324:2014-08Adhesives for tiles – Determination of shear adhesion strength of dispersion adhesives

EN 1346:2007-11Adhesives for tiles – Determination of open time

EN ISO 9001:2009-12Quality management systems – Requirements

EN 923:2015-06Adhesives – Terms and definitions

EN 1504-2:2015-03Products and systems for the protection and repair of concrete structures – Definitions, requirements, quality control and evaluation of conformity – Part 2: Surface protection systems for concrete

EN 1062-6:2002-10Paints and varnishes – Coating materials and coating systems for exterior masonry and concrete – Part 6: Determination of carbon dioxide permeability

EN ISO 7783:2012-02Paints and varnishes – Determination of water-vapour transmission properties – Cup method

EN 1062-3:2008-04Paints and varnishes – Coating materials and coating systems for exterior masonry and concrete – Part 3: Determination of liquid water permeability

EN 1542:1999-07Products and systems for the protection and repair of concrete structures – Test methods – Measurement of bond strength by pull-off

ETAG 022:2007-07Guideline for European technical approval of watertight covering kits for wetroom floors and/or walls – Part 1: Liquid-applied coverings with or without wearing surface

GEV/EMICODE:2010-07Gemeinschaft Emissionskontrollierte Verlegewerkstoffe, Klebstoffe und Bauprodukte e.V., Düsseldorf; www.emicode.de/

Blue AngelEnvironmental label organised by the federal government of Germany www.blauer-engel.de

Indoor Air ComfortProduct certification by Eurofins, Hamburg, Germany www.eurofins.com

Decopaint Directive 2004/42/EC: Directive 2004/42/EC of the European Parliament and of the Council of 21 April 2004 on the limitation of emissions of volatile organic compounds due to the use of organic solvents in certain paints and varnishes and in vehicle refinishing products and amending Directive 1999/13/EC, 2004-04

Harmonised conditions for the marketing of construction products:Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC

ISO 16000-3:2013-01Indoor air – Part 3: Determination of formaldehyde and other carbonyl compounds by sampling using a pump

ISO 16000-6:2012-11Indoor air – Part 6: Determination of volatile organic compounds indoors and in test chambers by sampling on TENAX TA®, thermal desorption and gas chromatography using MS or FID EN ISO 16000-9:2008-04 Indoor air – Part 9: Determination of the emission of volatile organic compounds from building products and furnishings – Emission test chamber method EN ISO 16000-11:2006-06 Indoor air – Part 11: Determination of the emission of volatile organic compounds from building products and furnishings – Sampling, storage of samples and preparation of test specimens

CEN/TS 16516:2015-07Construction products - Assessment of release of dangerous substances - Determination of emissions into indoor air

Royal Decree C-2014/24239Belgisch Staatsblad 8 MEI 2014, p. 60603. — Koninklijk besluit tot vaststelling van de drempelniveaus voor de emissies naar het binnenmilieu van bouwproducten voor bepaalde geoogde gebruiken

EN 17025: 2007-05General requirements for the competence of testing and calibration laboratories

AgBB Committee for Health-related Evaluation of Building Products: health-related evaluation of emissions of volatile organic compounds (VOC and SVOC) from building products; status: June 2012 www.umweltbundesamt.de/produkte/bauprodukte/agb b.htm

REACH Regulation:

11 Environmental Product Declaration FEICA – Dispersion-based products, Class A

Regulation (EC) No. 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), establishing a European Chemicals Agency, amending Directive 1999/45/EC and repealing Council Regulation (EEC) No. 793/93, Commission Regulation (EC) No. 1488/94 as well as Council Directive 76/769/EEC and Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC, 2006-12

Biocidal Products Regulation: Regulation (EU) No. 528/2012 of the European Parliament and of the Council of 22 May 2012 concerning the making available on the market and use of biocidal products, 2012-05

CML 2001: Institute of Environmental Sciences Leiden: CML method 2001, last update of characterization factors in November 2013, http://www.cml.leiden.edu/software/data-cmlia.html

Institut Bauen und UmweltInstitut Bauen und Umwelt e.V., Berlin(pub.):Generation of Environmental Product Declarations (EPDs);

General principlesfor the EPD range of Institut Bauen und Umwelt e.V. (IBU), 2013/04www.bau-umwelt.de

ISO 14025DIN EN ISO 14025:2011-10: Environmental labels and declarations — Type III environmental declarations — Principles and procedures

EN 15804EN 15804:2012-04+A1 2013: Sustainability of construction works — Environmental Product Declarations — Core rules for the product category of construction products

PublisherInstitut Bauen und Umwelt e.V.Panoramastr. 110178 BerlinGermany

Tel +49 (0)30 3087748- 0Fax +49 (0)30 3087748- 29Mail [email protected] www.bau-umwelt.com

Programme holderInstitut Bauen und Umwelt e.V.Panoramastr 110178 BerlinGermany

Tel +49 (0)30 - 3087748- 0Fax +49 (0)30 – 3087748 - 29Mail [email protected] www.bau-umwelt.com

Author of the Life Cycle Assessmentthinkstep AG Hauptstrasse 111 - 11370771 Leinfelden-EchterdingenGermany

Tel +49 (0)711 341817 0Fax +49 (0)711 341817 25Mail [email protected] www.thinkstep.com

Owner of the DeclarationFEICA - Association of the European Adhesive and Sealant IndustryAvenue E. van Nieuwenhuyse 4B-1160 BrusselsBelgium

Tel +32 (0)267 673 20 Fax +32 (0)267 673 99 Mail [email protected] www.feica.eu

Ultrabond Eco V4 SP Conductive EMICODE: EC1 Plus - very low emission

GEV EMICODE® Since 1997, the Association for the Control of Emissions in Products for Floor Installation, Adhesives and Building Materials (GEV) rewards low-emission flooring underlays and construction products with the quality mark GEV EMICODE®. In the focus of the tests according to ISO 16000 is the emissions' behaviour of the VOC which are, if meeting the EMICODE criteria, subdivided in 3 categories by the GEV: EMICODE EC1 PLUS - very low emission, EMICODE EC1 - very low emission and EMICODE EC2 - low emission.

The eco-INSTITUT is the testing laboratory being recommended by the GEV and tests your products accoring to the GEV EMICODE criteria. GEV classification criteria

µg/m3 after three days TVOC

after 28 days TVOC/TSVOC

EMICODE EC 1 PLUS - very low emission

≤ 750 ≤ 60/40

EMICODE EC 1 – very low emission ≤ 1000 ≤ 100/50 EMICODE EC 2 - low emission ≤ 3000 ≤ 300/100

EMICODE® quality mark

Documents

Classification Criteria for Construction Products Classification Criteria for Parquet Coatings

Links

Association for the Control of Emissions in Products for Flooring Installation, Adhesives and Building Materials

Jr. Federico Villareal N 277- 281 - BreñaTelfs: (01)650 1873 - (01)566 7215 ENTEL: 946330041

Cel.: 996 356 838 RPM:#996356838 RPC: 956 747182 [email protected]/[email protected]

Web Site:www.peruvinyl.peCopyright © Peruvinyl