step 7 escala mien to
TRANSCRIPT
![Page 1: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/1.jpg)
1) Abrir el programa STEP 7 (Administrador SIMATIC)
2) Siguiente sin modificar, aparece:
![Page 2: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/2.jpg)
3) Cambiar Lenguaje para todos los bloques a KOP:
![Page 3: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/3.jpg)
4) Nombre: Escalamiento y Finalizar
![Page 4: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/4.jpg)
5) Aparece la ventana SIMATIC Manager:
![Page 5: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/5.jpg)
6) Click en Equipo SIMATIC 300, ingresamos a Hardware:
![Page 6: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/6.jpg)
![Page 7: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/7.jpg)
7) En la ventana Hardware (HWConfig):
8) Cambiamos el CPU que está por defecto, lo borramos:
![Page 8: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/8.jpg)
9) Insertar el CPU 314C 2DP con Referencia: 6ES7 3146CF020AB0
![Page 9: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/9.jpg)
![Page 10: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/10.jpg)
![Page 11: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/11.jpg)
10) Guardar
![Page 12: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/12.jpg)
11) En SIMATIC Manager, abrir simulador (activar/desactivar simulación):
![Page 13: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/13.jpg)
![Page 14: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/14.jpg)
NOTA: Si aparece la ventana de Abrir Proyecto, dar click en Cancelar.12) Archivo Nuevo PLC:
![Page 15: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/15.jpg)
13) Insertar Entradas y Salidas:
![Page 16: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/16.jpg)
![Page 17: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/17.jpg)
14) Hacer cambios para entrada PEW752 y la marca MD0:
![Page 18: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/18.jpg)
15) En SIMATIC Manager:
![Page 19: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/19.jpg)
16) Ingresamos a OB1:
![Page 20: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/20.jpg)
![Page 21: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/21.jpg)
17) Vamos agregar la Función de Escalamiento: FC105 SCALEEn Librerías Standard Libraries TI S7 Converting Blocks FC 105 SCALE CONVERT:
![Page 22: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/22.jpg)
![Page 23: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/23.jpg)
18) Ingresando los valores de los parámetros:
![Page 24: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/24.jpg)
19) Herramientas Tabla de Símbolos:
![Page 25: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/25.jpg)
![Page 26: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/26.jpg)
Guardamos20) Regresamos a OB1:
21) Realizamos la carga:
![Page 27: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/27.jpg)
22) En modo Online (Observar Sí/No):
![Page 28: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/28.jpg)
![Page 29: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/29.jpg)
23) Cargamos el FC105 desde el SIMATIC Manager:
![Page 30: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/30.jpg)
![Page 31: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/31.jpg)
24) Nos vamos al simulador, poner modo RUN:
![Page 32: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/32.jpg)
CARGA AL PLC MEDIANTE EL CABLE PC ADAPTER USB1) Instalar el driver del PCD ADAPTER USB, está en la carpeta compartida2) Ajustar la Interface PG/PC desde el SIMATIC Manager:
![Page 33: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/33.jpg)
3) Seleccionar PC/ADAPTER MPI
![Page 34: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/34.jpg)
4) En Propiedades verificar Conexión Local a USB:
![Page 35: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/35.jpg)
5) Previamente verificar el tipo de Entrada Analógica en Hardware:
![Page 36: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/36.jpg)
6) En Hardware cargar en módulo:
![Page 37: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/37.jpg)
6) Aceptar y Mostrar:
![Page 38: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/38.jpg)
7)
![Page 39: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/39.jpg)
8) Aceptar, el CPU se pondrá en modo STOP:
![Page 40: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/40.jpg)
9) Aceptar:
![Page 41: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/41.jpg)
10) El CPU regresará a modo RUN:
![Page 42: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/42.jpg)
11) Cargar OB1:
![Page 43: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/43.jpg)
12) Cargar FC105:
![Page 44: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/44.jpg)
13) En OB1 Online:
![Page 45: Step 7 Escala Mien To](https://reader030.vdocuments.co/reader030/viewer/2022020716/545fb8a1b1af9f0e598b4efe/html5/thumbnails/45.jpg)