    Menu 1 Adjustment Menu (SEt)Factory

    Parameter Code Setting

    Speed Reference via the Display ModulePI ReferenceDirection of OperationAcceleration TimeDeceleration TimeAcceleration Ramp #2Deceleration Ramp #2Low SpeedHigh SpeedMotor Full Load Current (protection)Optimize Low Speed Torque (voltage boost)Slip Compensation

    Frequency Loop GainDC Injection Braking CurrentDC Injection Braking Time at StandstillSkip FrequencyJog FrequencyPI Regulator Proportional GainPI Regulator Integral GainPI Feedback Multiplication CoefficientPI Regulator Reverse CoefficientPreset Speed 2ndPreset Speed 3rdPreset Speed 4thPreset Speed 5thPreset Speed 6thPreset Speed 7thFrequency Threshold where R2 ClosesCurrent Threshold where R2 ClosesMotor Thermal where R2 ClosesLow Speed Operation Time

    Menu 2 Drive Menu (DrC)Factory

    Parameter Code Setting

    Nominal Motor VoltageNominal Motor FrequencyAuto-tuningMaximum Output FrequencyType of Volts/Hz RatioAutomatic Ramp Modification for DecelAlternate Accel/Decel Ramp FrequencyCarrier Switching FrequencyRandom Carrier Frequency ModulationAutomatic RestartEnable Output Phase Failure FaultEnable Line Supply Phase Failure FaultControlled Stop on Loss of Line SupplyEnable Smooth Restart after FaultLower Tripping Threshold of UndervoltageScale Factor of Output Frequency for SpeedReturn to Factory Settings

    Menu 3 I/O Menu (I-O)Factory

    Parameter Code Setting

    Control Strategy Configuration (2-wire/3-wire)2-Wire Control3-Wire ControlPresence of Local Control Option

    Enable for Start/Stop using Remote DisplayLogic Input 2 AssignmentLogic Input 3 AssignmentLogic Input 4 Assignment

    Not AssignedReverse RotationRamp Switching

    ALTIVAR 28 Quick Reference Guide

    Jog Operation2 Preset Speeds4 Preset Speeds8 Preset SpeedsFreewheel StopDC Injection BrakingFast StopForced Local ModeFault ResetAnalog Speed Reference Switching

    Analog Input Assignment of 2nd InputNot AssignedSumming with All

    PI Regulator Feedback, setpoint = parameter rP1PI Regulator Feedback, setpoint = AllMinimum Value on Analog Current InputMaximum Value on Analog Current InputAssignment of Analog Output

    Not AssignedMotor CurrentMotor FrequencyMotor TorqueDrive Power Supplied

    Assignment of Offset for Analog OutputAssignment of R2 Relay

    Not AssignedFrequency Threshold ReachedCurrent Threshold ReachedSpeed Reference ReachedMotor Thermal Threshold Reached

    Drive Address via Serial LinkSerial Link Transmission Speed

    Menu 4 Display Menu (SUP)Factory

    Parameter Code Setting

    Control Strategy Configuration (2-wire/3-wire)Enable for Start/Stop using Remote DisplayDisplay Calculated Value of Speed or

    Production Rate (rFr X SdS)Display Motor CurrentDisplay Motor PowerDisplay Line VoltageDisplay Motor Thermal StateDisplay Drive Controller Thermal StateDisplay Last FaultDisplay Drive Controller Software VersionAccess Code ProtectionDisplay of Controller Status

    If it is not possible to access the SEt-,

    drC- or I-O- menus, the drive controller

    is protected by an access code. A remote

    display module option or PC software is

    necessary to access these menus, together

    with knowledge of the code.

    Access to Menus

    ENT

    ENT

    ESC

    ESC

    -bFr

    SEt

    SUP-

    drC

    I-O-

    rdY

    ----

    bFR configuration (1)

    ENT

    0.0For3 sec3 sec5 sec5 sec0 Hz(bFr)(In)200.05.0 Hz

    330.7In0.5 sec0 Hz10 Hz11 /s1no10 Hz15 Hz20 Hz25 Hz30 Hz35 Hz(bFr)1.5In100%0

    230/460V50/60 Hzno60/72 HznYES0 Hz4.0YESnoYESYESnonono30no

    2C

    norrSPS2PS4

    SAI

    4 mA20 mArFr

    0SrA

    119.2

    HzHzA%V%%

    FactoryParameter Code Setting

    1st power-up after factory configuration

    Access to Parameters

    SEt-

    Menu Parameter

    Next parameter

    Value or assignment

    1 flash(save)

    Subsequent power-ups

    Display of drive controller status

    Wait 3 seconds

    Settings

    Drive

    I/O

    Display

    Base frequency:50 Hz (factory setting)or 60 Hz

    vv

    vv

    vv

    vv

    vv

    -YYY 100

    101-UUU 101

    ENT

    ESC

    Keypad Operation & Reference

    Using the Keypad Display

    Red LED: powered up(DC bus voltage)

    Returns to theprevious menu orparameter, orincreases thedisplayed value

    Enters a menu or aparameter, or saves

    the displayedparameter or value

    Exits a menu or parameter,

    or aborts the displayed valueto return to the previousvalue in the memory

    Goes to the next menu orparameter, or decreasesthe displayed value

    4 seven-segment displaysrdY

    Altivar28

    z

    vENTESCv

    LFr

    rPI

    rOt

    ACC

    dEC

    AC2

    dE2

    LSP

    HSP

    ItH

    UFr

    SLP

    FLG

    IdC

    tdC

    JPF

    JOG

    rPG

    rIG

    rbS

    PIC

    SP2

    SP3

    SP4

    SP5

    SP6

    SP7

    Ftd

    Ctd

    ttd

    tLS

    UnS

    FrS

    tUn

    tFr

    Ft

    brA

    Frt

    SFr

    nrd

    Atr

    OPL

    IPL

    StP

    FLr

    drn

    SdS

    FCS

    tCC

    2C

    3C

    OPt

    LCC

    LI2

    LI3

    LI4

    no

    rrS

    rP2

    JOG

    PS2

    PS4

    PS8

    nSt

    dCI

    FSt

    FLO

    rSt

    rFC

    AIC

    no

    SAI

    PII

    PIA

    CrL

    CrH

    AO

    no

    Ocr

    rFr

    OLO

    OPr

    AOt

    r2

    no

    FtA

    CtA

    SrA

    tSA

    Add

    bdr

    FrH

    rFr

    SPd

    LCr

    OPr

    ULn

    tHr

    tHd

    LFt

    CPU

    COd

    The parameters in colored boxes appear if the correspondingfunctions have been configured in the dcr or I/O menus.