granulometria 2

1
PROYECTO : UBICACIÓN : CACHICOTO , MONZON, HUAMALIES HUANUCO SOLICITA : CONSTRUCTORA CONSULTORA SHANDY EIRL - GOBIERNO REGIONAL HUANUCO CALICATA : CALICATA 2 - C2 - M2 PROFUNDIDAD : 2.00 - 2.80 mt. FECHA : NOVIEMBRE DEL 2013 TAMIZ DIÁMETRO % RETENIDO % RETENIDO % QUE (mm) PARCIAL ACUMULADO PASA 3" 76.200 2 1/2" 63.500 2" 50.800 1 1/2" 38.100 1" 25.400 3/4" 19.050 1/2" 12.700 3/8" 9.525 100.00 1/4" 6.350 0.21 0.21 99.79 Limite Liquido = 31.5 No 4 4.760 0.90 1.11 98.89 Limite Plástico = 18.7 No 8 2.380 0.62 1.73 98.27 Índice Plástico = 12.8 No 10 2.000 2.80 4.53 95.47 Coeficiente de Curvatura = N.P. No 16 1.190 5.43 9.96 90.04 Coeficiente de Uniformidad = N.P. No 20 0.840 10.08 20.04 79.96 No 30 0.590 10.30 30.35 69.65 SUCS : SC No 40 0.426 13.06 43.41 56.59 AASHTO : A-6 (3) No 50 0.297 5.67 49.08 50.92 No 60 0.250 1.82 50.89 49.11 % de grava = 1.11% No 80 0.177 2.76 53.65 46.35 % de arena = 57.19% No 100 0.149 1.21 54.87 45.13 % de limo y arcilla = 41.70% No 200 0.074 3.43 58.30 41.70 % de humedad = 22.93% CAZOLETA 0.000 41.70 100.00 0.00 suelo de color Amarillento con bandas plomizas TOTAL 100.00 68.8 30.2 85.5 1038.3 2490.0 CLASIFICACIÓN 256.5 325.2 141.2 OBSERVACIONES 45.2 5.3 22.3 15.5 69.6 135.3 251.1 58.30% LIMITES DE CONSISTENCIA DESCRIPCIÓN DE LA MUESTRA Arena arcillosa, con material granular equivalente a: CARACTERIZACION FISICA DE LA MUESTRA LABORATORIO DE GEOTECNIA, PAVIMENTOS Y MECÁNICA DE MATERIALES MEJORAMIENTO DE LA CAPACIDAD RESOLUTIVA DEL CENTRO DE SALUD CACHICOTO PESO TAMAÑO MÁXIMO RETENIDO 0 10 20 30 40 50 60 70 80 90 100 0.01 0.10 1.00 10.00 100.00 % QUE PASA, EN PESO DIÁMETRO DE LAS PARTÍCULAS DE SUELO (mm) GRAFICO DE LA GRANULOMETRÍA CON MALLAS ESTÁNDAR 3" 2" 1" 3/4" 1/2" 3/8" 1/4" 4 200 100 60 80 50 40 30 20 16 10 8 1 1/2" 400 800

Upload: dave-rivera-cruz

Post on 21-Dec-2015

214 views

Category:

Documents


0 download

DESCRIPTION

ENSAYO

TRANSCRIPT

Page 1: GRANULOMETRIA 2

PROYECTO :

UBICACIÓN : CACHICOTO , MONZON, HUAMALIES HUANUCOSOLICITA : CONSTRUCTORA CONSULTORA SHANDY EIRL - GOBIERNO REGIONAL HUANUCOCALICATA : CALICATA 2 - C2 - M2 PROFUNDIDAD : 2.00 - 2.80 mt.FECHA : NOVIEMBRE DEL 2013

TAMIZ DIÁMETRO % RETENIDO % RETENIDO % QUE

Nº (mm) PARCIAL ACUMULADO PASA

3" 76.200

2 1/2" 63.500

2" 50.800

1 1/2" 38.100

1" 25.400

3/4" 19.050

1/2" 12.700

3/8" 9.525 100.00

1/4" 6.350 0.21 0.21 99.79 Limite Liquido = 31.5No 4 4.760 0.90 1.11 98.89 Limite Plástico = 18.7No 8 2.380 0.62 1.73 98.27 Índice Plástico = 12.8

No 10 2.000 2.80 4.53 95.47 Coeficiente de Curvatura = N.P.No 16 1.190 5.43 9.96 90.04 Coeficiente de Uniformidad = N.P.No 20 0.840 10.08 20.04 79.96

No 30 0.590 10.30 30.35 69.65 SUCS : SC

No 40 0.426 13.06 43.41 56.59 AASHTO : A-6 (3)No 50 0.297 5.67 49.08 50.92

No 60 0.250 1.82 50.89 49.11 % de grava = 1.11%

No 80 0.177 2.76 53.65 46.35 % de arena = 57.19%

No 100 0.149 1.21 54.87 45.13 % de limo y arcilla = 41.70%

No 200 0.074 3.43 58.30 41.70 % de humedad = 22.93%

CAZOLETA 0.000 41.70 100.00 0.00 suelo de color Amarillento con bandas plomizas

TOTAL 100.00

68.8

30.2

85.5

1038.3

2490.0

CLASIFICACIÓN256.5

325.2

141.2 OBSERVACIONES45.2

5.3

22.3

15.5

69.6

135.3

251.1

58.30%

LIMITES DE CONSISTENCIA

DESCRIPCIÓN DE LA MUESTRA

Arena arcillosa, con material granular equivalente a:

CARACTERIZACION FISICA DE LA MUESTRALABORATORIO DE GEOTECNIA, PAVIMENTOS Y MECÁNICA DE MATERIALES

MEJORAMIENTO DE LA CAPACIDAD RESOLUTIVA DEL CENTRO DE SALUD CACHICOTO

PESOTAMAÑO MÁXIMO

RETENIDO

0

10

20

30

40

50

60

70

80

90

100

0.010.101.0010.00100.00

% Q

UE

PA

SA

, EN

PE

SO

DIÁMETRO DE LAS PARTÍCULAS DE SUELO (mm)

GRAFICO DE LA GRANULOMETRÍA CON MALLAS ESTÁNDAR3" 2" 1" 3/4" 1/2" 3/8" 1/4" 4 20010060 8050403020161081 1/2" 400 800