EPD Nº Registro: S-P-00811 DECLARACIÓN AMBIENTAL PRODUCTO ® ABN INSTAL CT FASER RD Ficha técnica Technical data sheet 01/2021 V.2 SISTEMA DE TUBERÍAS PARA INSTALACIONES HIDROSANITARIAS PIPING SYSTEM FOR HIDRAULIC LINES UNE 100030

Upload: others

Post on 05-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • EPDNº Registro: S-P-00811DECLARACIÓNAMBIENTALPRODUCTO

    ®

    ABN INSTAL CT FASER RD Ficha técnicaTechnical data sheet

    01/2021V.2

    SISTEMA DE TUBERÍAS PARA INSTALACIONES HIDROSANITARIASPIPING SYSTEM FOR HIDRAULIC LINES

    UNE 100030

  • Reglamentos y normativas |

    El producto |

    Usos principales | Main uses

    Ventajas | Benefits

    Características diferenciadoras | Differentiating features

    Lugares de aplicación | Application sites

    Gama de producto | Product range

    Tipos de unión | Joining techniques

    Accesorios | Fittings

    Valores técnicos | Technical data

    Valores ambientales | Environmental data

    Normas | Standards

    Certificados | Approvals

    Aplicaciones de la normativa | Application of standards

    Información complementaria | Additional information

    Standards and regulations

    The product

    Índice I Table of contents

  • La gama de producto ABN//INSTAL CT FASER RD cumple las exigencias de los reglamentos y normas que le son de aplicación en las instalaciones hidrosanitarias.

    The ABN // INSTAL CT FASER RD product range complies with the the regulations and standards that apply to hydraulic lines.

    Prevención y control de la proliferación y

    diseminación de Legionella en instalaciones.

    UNE 100030

    R.D.140Criterios Sanitarios de la

    Calidad del Agua deConsumo Humano

    R.D.865Criterios higiénico-sanitarios

    para la prevención y control de la legionelosis

    R.D.314/2006R.D.732/2019

    R.D.1027/2007R.D.1826/2009R.D. 238/2013RITE 2019 (propuesta de modificación)

    R.D.140/2003 R.D.865/2003

    UNE 100030/2017

    REGLAMENTOS Y NORMATIVAS REGULATIONS AND STANDARDS

  • Descripción tipo Text for tenders

    EL PRODUCTO | THE PRODUCT

    Ficha técnica ABN//INSTAL CT FASER RD | 01/2021Technical data sheet ABN//INSTAL CT FASER RD V2

    TUBO POLIPROPILENO PP RCT FASER RD

    Tubería ABN//INSTAL CT Faser RD, libre de halógenos, fabricada en PPR CT XP multicapa, para agua fría, A.C.S., calefacción y climatización, resistente a los procesos de desinfección, aditivo antimicrobiano, protección anti-incrustaciones, microfibras anti-dilataciones y protección UV. Serie ----, SDR ----, de diámetro exterior --- mm y espesor --- mm. Capa interna

    y capa externa color verde RAL 6024 con banda blanca RAL 9003. I/p.p. codos, tes y demás accesorios. 100% ecológico, reciclable, con Declaración Ambiental de Producto (DAP),

    y certificado por AENOR tubería, accesorios y sistema. Instalado según normativa vigente.

    color blanco RAL 9003

    clasificación ORO con el certificado C2C (CRADLE TO CRADLE)

    PP RCT FASER RD POLYPROPYLENE PIPE

    ABN // INSTAL CT Faser RD pipe, halogen free, manufactured in multi-layer PPR CT XP, for potable water application, heating and air-conditioning systems, resistant to disinfection processes, with antimicrobial additive, anti-incrustation protection, microfibers that prevent lineal expansion and UV protection. ---- series, SDR ----, external diameter of --- mm and thickness of --- mm. White internal layer and external layer with white strips. Proportional share of bends, t-pieces. 100% ecological and recyclable, with Environmental Product Declaration (EPD), GOLD classification with C2C certificate (CRADLE TO CRADLE) and Certificate of Compliance by AENOR for pipes, fittings and systems. Installed as standards.

    green RAL 6024

    Capa externa color verde RAL 6024 con bandas blancas RAL 9003 en PPR CT XP, resistente a los rayos UV. External layer in green RAL 6024 with white strips RAL 9003, manufactured in PPR CT XP, resistant to UV.

    Capa interna color blanco RAL 9003 en PPR CT XP con aditivo resistente a la desinfección, anti-incrustaciones y antimicrobiano.

    Internal layer in white RAL 9003 manufactured in PPR CT XP with a resistant to disinfection, anti-fouling and antimicrobial additive.

    Capa intermedia color gris RAL 7042 en PPR CT XP con microfibras anti-dilatación.Intermediate layer in silver RAL 7042 manufactured in PPR CT XP with anti-expansion microfibers.

    1

    2

    3

    1

    2

    3

    REDES DE DISTRIBUCIÓN DE AGUA FRÍA Y A.C.S.POTABLE WATER APPLICATION

    REDES DE CLIMATIZACIÓNAIR CONDITIONING SYSTEMS

    INSTALACIONES DE FLUIDOS A ALTAS Y BAJAS TEMPERATURASFLUIDS AT HIGH AND LOW TEMPERATURES FOR INDUSTRY

    SISTEMAS DE CALEFACCIÓNHEATING SYSTEMS

    USOS PRINCIPALES І MAIN USES

  • VENTAJAS | BENEFITS

    CARACTERÍSTICAS DIFERENCIADORAS | DIFFERENTIATING FEATURES

    LUGARES DE APLICACIÓN | APPLICATION SITES

    + +

    HF

    UV

    MAYOR RESISTENCIA A LA TEMPERATURA Y PRESIÓN HIGHER RESISTANCE TO TEMPERATURE AND PRESSURE

    BAJA CONDUCTIVIDAD TÉRMICALOW THERMAL CONDUCTIVITY

    LIGEREZALIGHTNESS

    RESISTENCIA A LA CORROSIÓNCORROSION RESISTANCE

    MAYOR SECCIÓN HIDRAÚLICAGREATER HYDRAULIC SECTION

    ECONÓMICO Y EFICIENTEECONOMIC AND EFFICIENT

    LIBRE DE HALÓGENOSHALOGEN FREE

    RESISTENCIA A LOS PROCESOS DE DESINFECCIÓNRESISTANCE TO DISINFECTION PROCESSES

    PROTECCIÓN ANTIMICROBIANAANTIMICROBIAL PROTECTION

    MICRO FIBRAS ANTI DILATACIÓNANTI-EXPANSION MICRO-FIBERS

    CAPA INTERNA ANTI-INCRUSTACIONES ANTI-FOULING INTERNAL LAYER

    CAPA EXTERNA DE PROTECCIÓN UVUV PROTECTION EXTERNAL LAYER

    ECOLÓGICO Y RECICLABLEECOLOGICAL AND RECYCLABLE

    HOTELSHOTELS

    HOSPITALESHOSPITALS

    CENTROS COMERCIALES

    SHOPPING CENTRES

    GARAJESGARAGES

    EDIFICIOS INSTITUCIONALES

    INSTITUTIONAL BUILDINGS

    EDIFICIOS DE OFICINAS

    OFFICE BUILDINGS

    AEROPUERTOSAIRPORTS

    EDIFICIOS RESIDENCIALES

    RESIDENTIAL BUILDINGS

    INSTALACIONES DEPORTIVAS

    SPORTS FACILITIES

    CENTROS DOCENTESTEACHING CENTERS

    MUSEOSMUSEUMS

    EDIFICIOS INDUSTRIALES

    INDUSTRIAL BUILDINGS

    CINES Y TEATROSCINEMAS AND

    THEATRES

    EDIFICIOSPENITENCIARIOS

    PENITENTIARY CENTRES

    Ficha técnica ABN//INSTAL CT FASER RD | 01/2021Technical data sheet ABN//INSTAL CT FASER RD V2

  • Tipo de unión | Joining techniques

    CÓDIGO

    Code

    DOCTF32020000

    DOCTF32025000

    DOCTF32032000

    DOCTF50040000

    DOCTF50050000

    DOCTF50063000

    DOCTF50075000

    DOCTF50090000

    DOCTF50110000

    DOCTF50125000

    DOCTF50160000

    (mm)

    20

    25

    32

    40

    50

    63

    75

    90

    110

    125

    160

    (mm)

    2.8

    3.5

    4.4

    3.7

    4.6

    5.8

    6.8

    8.2

    10.0

    11.4

    14.6

    GAMA DE PRODUCTO / PRODUCT RANGE

    Serie/

    SDR

    3,2/7.4

    3.2/7.4

    3.2/7.4

    5/11

    5/11

    5/11

    5/11

    5/11

    5/11

    5/11

    5/11

    (m)

    4,0

    4,0

    4,0

    4,0

    4,0

    4,0

    4,0

    4,0

    4,0

    5,8

    5,8

    *Longitudes de tubo bajo demanda: barras hasta 13 m*On request 42,65 ft lengths.

    DIÁMETRODiameter

    ESPESORthickness

    (in)

    0.11

    0.14

    0.17

    0.15

    0.18

    0.23

    0.27

    0.32

    0.39

    0.45

    0.57

    LONGITUDlength

    (ft)

    13.12

    13.12

    13.12

    13.12

    13.12

    13.12

    13.12

    13.12

    13.12

    19.00

    19.00

    (kg/m)

    0.150

    0.233

    0.374

    0.445

    0.682

    1.025

    1.435

    2.077

    3.101

    4.008

    6.558

    PESOweight

    (lb/ft)

    1.08

    1.68

    2.70

    3.22

    4.93

    7.41

    10.39

    15.02

    22.43

    28.99

    47.43

    (in)

    1/2"

    3/4"

    1"

    1 1/4"

    1 1/2"

    2"

    2 1/2"

    3"

    4"

    5"

    6"

    •Soldadura a socket (para diámetros de 20 a 160 mm) Socket welding (for diameters from ½" to 6" )

    •Soldadura a tope (para diámetros de 90 a 160 mm) Butt welding (for diameters from 3" to 6" )

    •Soldadura por electrofusión (para diámetros de 20 a 160 mm) Electrofusion welding (for diameters from 1/2" to 6")

    Co2

    (kg)

    0.56

    0.86

    1.39

    1.65

    2.53

    3.80

    5.32

    7.71

    11.50

    14.87

    24.33

    Agua

    Water

    (litros)

    4.96

    7.71

    12.38

    14.73

    22.57

    33.92

    47.48

    68.73

    102.61

    132.62

    217.00

    Impacto ambiental Environmental impact

    CO2RoHS

    Energía

    Energy

    (MJ)

    7.16

    11.12

    17.85

    21.24

    32.55

    48.91

    68.48

    99.11

    147.98

    191.26

    312.95

    Compr.con RoHS

    RoHScommitm.

    Uso alimet.

    Food use

    Fin de vida útilEnd of firts life

    ¨Reutilizar/

    Re-use

    Reciclar/Recycle

    ¨Ciclo de

    degradación/Downcycle

    ¨Combustión/ Combustion

    ¨Vertedero/

    Landfill

    ¢

    Tuberías | Pipelines

    Los sistemas ABN//INSTAL CT FASER RD se unen mediante soldadura de termofusión. A continuación se indican los distintos tipos, y el rango de diámetros para cada uno de ellos:

    ABN // INSTAL CT FASER RD systems are joined by thermofusion. Different techniques and the range of diameters for each of them are described below:

    Termofusión | Thermofusion

    Ficha técnica ABN//INSTAL CT FASER RD | 01/2021Technical data sheet ABN//INSTAL CT FASER RD V2

  • Accesorios | Fittings

    Material | Material Color | ColourPP RCT RP Verde | Green

    GAMA ACCESORIOS SOLDAR A SOCKET /

    Dispone de una amplia gama de accesorios de diámetros comprendidos entre 20 a 160 mmWide range of fittings from 1/2" to 6" mm

    SOCKET WELDING FITTINGS

    GAMA ACCESORIOS SOLDAR A TOPE BUTT WELDING FITTINGS

    La gama comprende accesorios manipulados de diámetro 90 a 160 mmThe range includes manipulated fittings of diameters 3 "to 6"

    GAMA ACCESORIOS SOLDAR POR ELECTROFUSIÓNELECTROFUSION WELDING FITTINGS

    Los accesorios por electrofusión disponen de una gama de 20 a 160 mmElectrofusion fittings range from ½ "to 6"

    HF

    UV

    LIBRE DE HALÓGENOSHALOGEN FREE

    RESISTENCIA A LOS PROCESOS DE DESINFECCIÓNRESISTANCE TO DISINFECTION PROCESSES

    PROTECCIÓN ANTIMICROBIANAANTIMICROBIAL PROTECTION

    CAPA EXTERNA DE PROTECCIÓN UV UV PROTECTION EXTERNAL LAYER

    ECOLÓGICO Y RECICLABLEECOLOGICAL AND RECYCLABLE

    COLECTORES Y PIEZAS ESPECIALES MANIFOLDS AND SPECIAL PARTS

    CARACTERÍSTICAS DIFERENCIADORAS l DIFFERENTIATING FEATURES

    3.000

    250 500 500 500 500 500 250

    150

    250

    350

    250

    Ø110 Ø125 Ø110 Ø110

    Ø160 Ø50- 1 ½” M750750

    Ø63- 2" M

    1.250

    ABN//INSTAL CT FASER RD FIRE Ø160 serie 5- SDR 11

    Ø90

    Ficha técnica ABN//INSTAL CT FASER RD | 01/2021Technical data sheet ABN//INSTAL CT FASER RD V2

  • Material / Material PPR CT RP + FV

    Densidad / Density 905 kg/m3 según ISO 1183

    Índice de fluidez en masa / Melt mass flow rate 0,30 g/10 min según ISO 1133

    Coeficiente de dilatación térmica lineal / Lineal expansion coefficient 0,035 mm/m ºC

    Módulo de elasticidad / Elastic modulus 900 Mpa según ISO 527

    Coeficiente de conductividad térmica/ Thermal expansion coefficient 0.24 w/mk según DIN 52612

    Fabricación / Production EN ISO 15874/DIN 8077/DIN 8078

    Presiones con 50 años de funcionamiento según DIN 8077 (SF: 1,25)Working pressures for 50 years according to DIN 8077 (SF: 1.25)

    Serie

    3.2

    5

    *Para esta temperatura son 25 años /25 years for this temperature

    bar

    31.7

    20.3

    psi

    459.8

    294.4

    20ºC/68ºF

    bar

    17.7

    11.3

    psi

    256.7

    163.9

    60ºC/140ºF

    bar

    14.9

    9.5

    psi

    216.1

    137.8

    70ºC/158ºF

    bar

    12.7

    8.1

    psi

    184.2

    117.5

    80ºC/176ºF*

    La gama ABN//INSTAL CT FASER RD (tubería + accesorios) están libres de halógenos.

    The ABN // INSTAL CT FASER RD range (pipe + fittings) are halogen-free.

    Valores técnicos | Technical values

    Ficha técnica ABN//INSTAL CT FASER RD | 01/2021Technical data sheet ABN//INSTAL CT FASER RD V2

  • Etapa del productoProduct

    stage

    Mat

    eria

    prim

    aR

    aw m

    ater

    ials

    Tran

    spor

    teTr

    ansp

    ort

    Fabr

    icac

    ión

    Man

    ufac

    turin

    g

    Tran

    spor

    teTr

    ansp

    ort

    Inst

    alac

    ión

    en o

    bra

    Cons

    tuct

    ion

    inst

    alla

    tion

    Uso

    Use

    Man

    teni

    mie

    nto

    Mai

    nten

    ance

    Rep

    arac

    ión

    Rep

    air

    Rem

    plaz

    oR

    epla

    cam

    ent

    Rem

    odel

    ació

    nR

    efur

    bish

    men

    t

    Uso

    ope

    raci

    onal

    de

    ener

    gía

    Ope

    ratio

    nal e

    nerg

    y us

    e

    Uso

    ope

    raci

    onal

    de

    agua

    Ope

    ratio

    nal w

    ater

    use

    De c

    onst

    rucc

    ión

    - dem

    olic

    ión

    De-c

    onst

    ruct

    ion

    - dem

    oliti

    on

    Proc

    esam

    ient

    o de

    resi

    duos

    W

    aste

    pro

    cess

    ing

    Tran

    spor

    teTr

    ansp

    ort

    Elim

    inac

    ión

    Disp

    osal

    Pote

    ncia

    l de

    reut

    iliza

    ción

    - re

    cupe

    raci

    ón -

    reci

    claj

    eR

    euse

    - R

    ecov

    ery

    - R

    ecyc

    ling

    - pot

    entia

    l

    Transporte e instalaciónConst. process

    stage

    Final del ciclo de vidaEnd of life stage

    Etapa de recuperación de recursos

    Resource recovery stage

    A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D

    Etapa de usoUse stage

    MND ( módulo no declarado | module non declared)

    Valores ambientales | Environmental values

    SYSTEM BOUNDARIES

    Boundary for the LCA has been set in a cradle-to-gate approach, thus therefore only Modules A1-A3 (mandatory) has been addressed.

    The objective of this EPD is address the environmental footprint of manufacturing both ABN//INSTAL CT FASER RD family pipes. These pipes are intended for a wide number o applications, leading to a great variability of cases for both Construction and end of life stages, which are outside the outreach of ABN Pipes.

    Our piping system do not require any maintenance or replacement during its service life (over 50 years).

    Due to this, all stages downstream the manufacturing process has been excluded from the lifecycle, and thus, according to the PCR instructions, only A1-A3 modules have been addressed.

    According to PCR and General Programme Instructions, recycling of non-compliant products have been omitted, as this material is grinded and re-used in the same process.

    LÍMITES DEL SISTEMA

    La frontera para el ACV se ha establecido en un enfoque desde la cuna hasta la puerta, por lo tanto, solo se han abordado los módulos A1-A3 (obligatorio).

    El objetivo de esta EPD es abordar la huella ambiental de la fabricación de tuberías de la familia ABN// INSTAL CT FASER RD. Estos tubos están diseñados para un gran número de aplicaciones, lo que conduce a una gran variabilidad de casos tanto para la construcción como para el final de la vida útil, que están fuera del alcance de ABN Pipe.

    Nuestro sistema de tuberías no requiere ningún mantenimiento o reemplazo durante su vida útil (más de 50 años).

    Debido a esto, todas las etapas posteriores al proceso de fabricación se han excluido del ciclo de vida y, por lo tanto, de acuerdo con las instrucciones de PCR, solo se han abordado los módulos A1-A3.

    Según el PCR (Product Construction Rules) y las instrucciones generales del programa, se ha omitido el reciclaje de productos no conformes, ya que este material se tritura y se reutiliza en el mismo proceso.

    Ficha técnica ABN//INSTAL CT FASER RD | 01/2021Technical data sheet ABN//INSTAL CT FASER RD V2

  • Las siguientes tablas muestran el impacto ambiental del sistema de tuberías FASER, desglosado en los tres módulos (materias primas, transporte y producción). Para todas las categorías analizadas, los resultados muestran que la producción de materia prima es el principal contribuyente al impacto ambiental del sistema de tuberías FASER, seguido de la producción y el transporte de las tuberías.

    PARÁMETRO/ PARAMETER

    Potencial de calentamiento global (GWP)Global warming potential (GWP)

    Potencial de agotamiento la capa de ozono estratosferíco (ODP) Depletion potential of the stratospheric ozone layer (ODP)Potencial de acidificación (AP)Acidification potential (AP)

    Potencial de eutrofización (EP)Eutrophication potential (EP)

    Potencial de formación del ozono troposférico (POCP)Potencial formation of troposferic ozone (POCP)

    Potencial de agotamiento abiótico - ElementosAbiotic Potential Depletion- Elements

    Potencial de agotamiento abiótico - Recursos fósilesAbiotic Potential Depletion- Fossil resources

    Potencial de escasez de aguaWater scarcity potential

    UNIDAD/ UNIT

    kg CO eq.2

    kg CFC 11 eq.

    kg S0 eq.2

    3kg PO eq4

    kg C H eq2 4

    kg Sb eq.

    MJ, net calorific value

    3m eq.

    A1

    2.22

    3.14E-08

    2.58E-02

    6.84E-03

    1.28E-03

    2.70E-04

    66.15

    0.72

    A2

    0.38

    6.92E-08

    9.44E-04

    1.18E-04

    5.94E-05

    1.14E-06

    6.00

    0.04

    A3

    0.31

    2.79E-08

    1.59E-03

    2.55E-04

    2.07E-04

    1.07E-06

    6.10

    0.16

    TOTAL

    2.91

    1.29E-07

    2.83E-02

    7.21E-03

    1.54E-03

    2.73E-04

    78.25

    0.91

    UNIDAD DECLARADA PARA TODOS LOS DATOS MOSTRADOS: 1 kg de sistemas de tuberías

    DECLARED UNIT FOR ALL DATA SHOWN:1 kg of piping systems

    The next tables show the environmental impact of the ENERGY piping system, broken down in three modules (raw materials, transport and production). For all categories analysed, results show that raw material production is the main contributor to the environmental impact of FASER piping system, followed by pipe production and transportation.

    Valores ambientales | Environmental performance

    Ficha técnica ABN//INSTAL CT FASER RD | 01/2021Technical data sheet ABN//INSTAL CT FASER RD V2

  • Con respecto al consumo de energía, la producción de materia prima es la etapa más intensiva en energía primaria no renovable, mientras que la producción de tuberías es el principal consumidor de energía primaria de fuentes renovables.

    Recursos de energía primaria RenovablesPrimary energy resources. Renewable

    Recursos de energía primaria no renovablesPrimary energy resources. Non-renewable

    Use como transporte de energíaUse as energy carrierUso como materia primaUse as raw materialsTOTAL

    Use como transporte de energíaUse as energy carrierUso como materia primaUse as raw materialsTOTAL

    Mj, valor calorífico netoMj, net calorific value

    Mj, valor calorífico netoMj, net calorific value

    kg

    Mj, valor calorífico netoMj, net calorific value

    3m

    1.46

    0

    1.46

    70.49

    0

    70.49

    0

    0

    0

    2.08E-02

    0.07

    0

    0.07

    6.10

    0

    6.10

    0

    0

    0

    1.16E-03

    8.10

    0

    8.10

    6.71

    0

    6.71

    0

    0

    0

    4.43E-03

    9.63

    0.02

    9.63

    83.30

    0

    83.30

    0

    0

    0

    2.64E-02

    Material secundarioSecondary material

    Combustibles secundarios renovablesRenewable secondary fuels

    Combustibles secundarios no renovablesNon-renewable secondary fuels

    Uso neto de agua dulceNet use of fresh water

    PARÁMETRO/ PARAMETER UNIDAD/ UNIT A1 A2 A3 TOTAL

    Regarding energy consumption, the production of raw materials is the most intensive stage in non-renewable primary energy, while the production of pipes is the main consumer of primary energy.

    Valores ambientales | Environmental performance

    Con respecto a la producción de residuos en el proceso, la mayoría de los residuos generados durante el proceso están catalogados como residuos no peligrosos.

    Residuos peligrosos (kg)Hazardous waste (kg)

    Residuos no peligrosos (kg)Non-hazardous waste (kg)

    Residuos radioactivos (kg)Radioactive waste (kg)

    PARÁMETRO/ PARAMETER A1 A2 A3 TOTALRegarding the production of waste in the process, most of the waste produced during the process is classified as non-hazardous waste.

    En el cuadro adjunto se detallan los valores obtenidos en las distintas categorías y la certificación general.

    Certificación ambiental Cradle to Cradle

    The attached table details the values obtained in the different categories and the general certification.

    Cradle to Cradle environmental certificate

    8.23E-05

    1.35E-01

    1.68E-05

    3.44E-06

    2.73E-01

    3.93E-05

    8.99E-05

    6.43E-02

    1.56E-05

    9.48E-05

    4.73E-01

    7.17E-05

    Ficha técnica ABN//INSTAL CT FASER RD | 01/2021Technical data sheet ABN//INSTAL CT FASER RD V2

  • Normas | Standards

    –UNE EN ISO 15874. Plastics piping systems for hot and cold water installations - Polypropylene (PP) - Part 1: General (ISO 15874-1:2013).

    –RP 01.78 - AENOR Particular Regulation of the Certificate of AENOR Compliance for Systems Random Polypropylene pipeline with modified crystal structure (PP-RCT) and fiberglass (FV) for hot and cold water installations in the interior of the building structure.

    •DIN 8077. RCT. Dimensions.

    •DIN 8078. Polypropylene (PP) pipes - PP-H, PP-B, PP-R, PP-RCT. General quality requirements and testing.

    –Royal Decree 140/2003, of 7 February, which establishes sanitary criteria for the quality of water for human consumption.

    •UNE 100030. Guidelines for prevention and control of proliferation and spread of Legionella in facilities.

    •UNE EN 15804 + A1. Sustainability of construction works - Environmental product declarations. Core rules for the product category of construction products.

    •UNE EN ISO 14040. Environmental management - Life cycle assessment - Principles and framework.

    •UNE EN ISO 14044. Environmental management - Life cycle assessment - Requirements and guidelines

    •UNE EN ISO 14025. Environmental labels and declarations - Type III environmental declarations - Principles and procedures.

    Polypropylene (PP) pipes –PP-H, PP-B, PP-R, PP-

    El sistema ABN//INSTAL CT FASER RD está diseñado, producido, ensayado y certificado según las siguientes normas:The ABN // INSTAL CT FASER RD system is designed, manufactured, tested and certified according to the following standards:

    –UNE EN ISO 15874. Sistemas de canalización en materiales plásticos para instalaciones de agua caliente y fría. Polipropileno (PP). Parte 1: Generalidades. (ISO 15874-1:2013).

    •RP 01.78. Reglamento Particular del Certificado de Conformidad AENOR para Sistemas de canalización en Polipropileno Random con estructura cristalina modificada (PP-RCT) y fibra de vidrio (FV) para instalaciones de agua caliente y fría en el interior de la estructura de los edificios.

    •DIN 8077. Tubos de polipropileno (PP) –PP-H, PP-B, PP-R, PP-RCT. Dimensiones.

    •DIN 8078. Tubos de polipropileno (PP) - PP-H, PP-B, PP-R, PP-RCT. Requisitos y pruebas generales de calidad.

    –RD 140/2003. Real Decreto 140/2003, de 7 de febrero, por el que se establecen los criterios sanitarios de la calidad del agua de consumo humano.

    •UNE 100030. Prevención y control de la proliferación y diseminación de Legionella en instalaciones.

    •UNE EN 15804 +A1. Sostenibilidad en la construcción. Declaraciones ambientales de producto. Reglas de categoría de producto básicas para productos de construcción.

    •UNE EN ISO 14040. Gestión ambiental. Análisis del ciclo de vida. Principios y marco de referencia.

    •UNE EN ISO 14044. Gestión ambiental. Análisis del ciclo de vida. Requisitos y directrices.

    •UNE EN ISO 14025. Etiquetas y declaraciones ambientales. Declaraciones ambientales tipo III. Principios y procedimientos.

    Ficha técnica ABN//INSTAL CT FASER RD | 01/2021Technical data sheet ABN//INSTAL CT FASER RD V2

  • Certificados | Approvals

    Certificado de Conformidad AENOR : ESPECIFICACIÓN TÉCNICA 001.78

    Certificate of conformity AENOR: TECHNICAL SPECIFICATION TO RP

    Certificado de Conformidad AENOR : ESPECIFICACIÓN TÉCNICA 001.78

    Certificate of conformity AENOR: TECHNICAL SPECIFICATION TO RP

    001.78

    Certificado AENOR – UNE EN ISO 15874

    AENOR Product Certificate-UNE EN 15874

    RD 140/2003 - Real Decreto 140/2003.

    Royal Decree 140/2003

    Declaración ambiental de producto EPD Environmental Product Declaration EPD

    Certificado Cradle to Cradle

    Cradle to Cradle Certificate

    Ficha técnica ABN//INSTAL CT FASER RD | 01/2021Technical data sheet ABN//INSTAL CT FASER RD V2

  • Sección HS4 - SUMINSTRO DE AGUA

    Cumplimiento del Real Decreto 140/2003

    Resistentes a la corrosión interior

    No deben de presentar incompatibilidad electroquímica entre si

    La instalación de suministro de agua debe de tener características adecuadas para evitar el desarrollo de gérmenes patógenos y no favorecer el desarrollo de la biocapa

    La temperatura de ACS en los puntos de consumo debe estar comprendida entre 50 ºC y 65 ºC

    ABN//INSTAL CT FASER RD

    Dispone del ensayo Real Decreto 140/2003

    Es resistentes a la corrosión interior

    No presenta incompatibilidad electroquímica

    Dispone de un tratamiento antimicrobiano que reduce la formación de biofilm e impide el desarrollo de gérmenes patógenos.

    Soportan temperaturas superiores a las exigidas (95ºC)

    EXIGENCIAS DEL CTE - Documento Básico Salubridad

    Aplicación de la normativa | Application of standards

    Real Decreto 865/2003, Criterios higiénico-sanitarios para la prevención y control de la legionelosis.

    Artículo 1. Objeto

    Este real decreto tiene como objeto la prevención y control de la legionelosis mediante la adopción de medidas higiénico-sanitarias en aquellas instalaciones en las que la Legionella es capaz de proliferar y diseminarse.

    Los sistemas de tuberías ABN//INSTAL CT FASER RD tienen incorporado un tratamiento antimicrobiano que ayuda a reducir las bacterias coliformes y la legionella.

    ABN//INSTAL CT FASER RD es apto para soportar los tratamientos tanto térmicos como químicos indicados en dicho regalmento

    A continuación se realiza una pequeña síntesis de las exigencias normativas para las instalaciones y cómo contribuye ABN//INSTAL CT FASER RD a su cumplimiento.Below you can find a brief summary of the regulatory requirements for the facilities and how ABN // INSTAL CT FASER RD contributes to their compliance.

    Ficha técnica ABN//INSTAL CT FASER RD | 01/2021Technical data sheet ABN//INSTAL CT FASER RD V2

  • Válido hasta el 31 de diciembre de 2018

    Manufacturedin

    Spain

    PIPE SYSTEMS

    CENTRAL

    CTRA. BAÑOS DE ARTEIXO, 28PARQUE EMPRESARIAL AGRELA15008 A CORUÑA (ESPAÑA)

    T. +34 902 202 532F. +34 902 253 240

    PLANTA DE PRODUCCIÓN (con certificación)

    PARQUE EMPRESARIAL MEDINA ONAUTOVÍA A-6, KM 15247400 MEDINA DEL CAMPO(VALLADOLID)

    [email protected]

    Distribuidor/ Distributor

    TUBGrupo Sectorial Tuberías Plásticas de

    Miembro de:

    Página 1Página 2Página 3Página 4Página 5Página 6Página 7Página 8Página 9Página 10Página 11Página 12Página 13Página 14Página 15Página 16