Download - Aliviaderos
FACULTAD DE ARQUITECTURA E INGENIERIA CIVIL Y DEL AMBIENTEPROGRAMA PROFESIONAL DE INGENIERIA CIVIL
DISEÑO HIDRAULICO - ALIVIADEROS
Presentado por:
AREQUIPA – PERÚ2015
UNIVERSIDAD CATÓLICA DE SANTA MARÍA
Semestre: X
FLORES HAÑARI, Almilcar Santiago
ALIVIADEROS
DATOS DEL CANAL
n= 0.016
b= 2 m
z= 0.5
S= 0.000284
Qn= 6 m3/s
M= 5
L = 19 m
Qmax = 7.2 m3/s
Sobreelevacion del umbral 0 m
1.- CALCULAR LAS DIMENSIONES DEL CANAL
Q*n/(s^1/2): y= 1.998391124 <- tanteo5.696551959 = 5.696455218
Calado Y = 2 <- redondeadoAltura del umbral= 2
Q*n/(s^1/2) = 5.696551959((b+zy)y)^(5/3)= 19.77616732
(b+2y(1+Z^2)^0.5)^(2/3)= 3.471662036
((b+zy)y)^(5/3) 5.696455218
(b+2y(1+Z^2)^0.5)^(2/3)
2.- SUPONIENDO Qv
3/2
3/5
2/1
.*
P
A
S
nQ
yyzbA )*( 21*2 zybP
Qv = 0.7608 m3/s <- tanteo
Q2 = Q - Qv 6.4392 m3/s
2.- CALCULO DE TIRANTE Y2
Y2 = 2.080062691 <- tanteoQn2/S^0.5 = 6.113539563
((b+zy)y)^(5/3) = 21.62340803(b+2y(1+Z^2)^0.5)^(2/3) = 3.536700893
((b+zy)y)^(5/3) 6.114005305
(b+2y(1+Z^2)^0.5)^(2/3)
H2=Y2 - Umbral 0.080062691 m
A2=(b+ZY2)Y2 = 6.323455782 m2V2=Q2/A2 = 1.01830395 m/seghv = 0.052851322 mE2=y2+hv = 2.132914013 m
3.- HALLANDO C CON Qv=CMLH2^(3/2)
Y1= 2.080056915 <- tanteo
A1=(b+ZY2)Y2 = 6.323432213 m2V1=Q1/A1 = 1.018307745 m/seghv = 0.052851716 mE2=y1+hv = 2.13290863 m
H1=Y1 - Umbral 0.080056915 mK= H1/H2 = 0.999927849
C= (2/5) ((1-K^(5/2))/(1-k)) = 0.999945887
Q1= (2gA1^2(E2-Y1))^0.5 6.43952789
ALIVIADEROS
ALIVIADEROS
DATOS DEL CANAL
n= 0.015
b= 4 m
z= 0
S= 0.0004
Qn= 10.7
Q1 = Qmax= 15 m3/s
M= 2
Qv= 3 m3/s
Sobreelevacion del umbral 0 m
1.- CALCULAR LAS DIMENSIONES DEL CANAL
Q*n/(s^1/2): y= 2.00467458 <- tanteo8.025 = 8.024937158
Calado Y = 2.005 <- redondeadoAltura del umbral= 2.005
Q*n/(s^1/2) = 8.025((b+zy)y)^(5/3)= 32.12475257
(b+2y(1+Z^2)^0.5)^(2/3)= 4.00311578
((b+zy)y)^(5/3) 8.024937158
(b+2y(1+Z^2)^0.5)^(2/3)
2.- CALCULO DE TIRANTE Y2
Q2 = 12
3/2
3/5
2/1
.*
P
A
S
nQ
yyzbA )*( 21*2 zybP
y2 = 2.185885551 <- tanteoQn2/S^0.5 = 9
((b+zy)y)^(5/3) = 37.10898003(b+2y(1+Z^2)^0.5)^(2/3) = 4.122983185
((b+zy)y)^(5/3) 9.000516948
(b+2y(1+Z^2)^0.5)^(2/3)
A2=(b+ZY2)Y2 = 8.743542202 m2V2=Q2/A2 = 1.37244148 m/seghv = 0.096003854 mE2=y2+hv = 2.281889405 m
3.- CALCULO DE TIRANTE Y1
Y1= 2.185860172 <- tanteo
E1=y1+hv1A1= (b+zy)y = 8.743440687
E1= y1+Q^2/(2gA^2) = 2.281866255 m
H2=Y2 - Umbral 0.180885551 mH1 =Y1 -Umbral 0.180860172 m
K= H1/H2 = 0.999859697
C= (2/5) ((1-K^(5/2))/(1-k)) = 0.999894775
Qv = CMbH2^(3/2)b= Qv/(CMH2^(3/2)) = 19.4998444 m
ALIVIADEROS
ALIVIADERO
Definición de Aliviadero
Características de un aliviadero
ü El aliviadero es el elemento de los embalses que permiten la evacuación de los caudales de avenida.
ü Los aliviaderos cumplen siempre la misma función con independencia de que estén situados en una presa elaborada con hormigón o en una realizada a partir de materiales sueltos; su misión es la de evitar que el agua del embalse se vierta por la coronación (parte superior) de la presa cuando se presenta la máxima avenida. Esta situación podría provocar el derrumbe de la presa y una importante catástrofe que podría poner en peligro terrenos, bienes y vidas.
1. Liberar parte del agua detenida sin que esta pase por la sala de maquinas.se encuentran en la pared principal de la presa y pueden ser de fondo o de superficie
2. Garantizar la seguridad de la estructura hidráulica, al no permitir la elevación del nivel, aguas arriba, por encima del nivel máximo.