3
DISEÑO ACEROPA UNA VIGA CARACTERISTICAS GEOMETRICA DE LA VIGA Ancho b (cm)= 25 Recubrimiento d' (cm)= 5 Altura h (cm)= 40 Recubrimiento r (cm)= 5 PROPIEDADES DE LA VIGA Momento Ultimo (Tn.m)= 15 210 4200 Tipo de Zona= Factor de reducción (ø)= 0.9 RESULTADOS INICIALES peralte efectivo d (cm)= 35 b1= 0.85 pb= 0.021675 13.95699876 p= 0.015950856 0.0108375 0.003333333 9.4828125 2.916666667 EL ACERO FLUYE (FALLA DUCTIL) No utilizar Acero Minimo ENTONCES: As (cm²)= 13.95699876 REQUIERE ACERO EN COMPRESIÓN Momento Maximo (tn.m) = 10.94617642 Momento que Falta (tn.m)= 4.053823582 As2 (cm²)= 3.574800337 As (cm²)= 13.05761284 <===RESULTADO A's (cm²)= 4.549745883 <===RESULTADO istencia del concreto a los 28 dias f'c (kg/cm²)= Fluencia del acero fy (kg/cm²)= ::::::::::::::::::::::::::::::::::::::::::::::::::::::: As (cm²)= pmax.= pmin.= As max. (cm²)= As min. (cm²)= h b A A

Upload: davidparedes

Post on 16-Dec-2015

8 views

Category:

Documents


1 download

DESCRIPTION

Diseño Ce Acero Para Una Viga para una viga determinada

TRANSCRIPT

Hoja1DISEO ACEROPA UNA VIGACARACTERISTICAS GEOMETRICA DE LA VIGAAncho b (cm)=25Recubrimiento d' (cm)=5Altura h (cm)=40Recubrimiento r (cm)=51SismicaPROPIEDADES DE LA VIGA2No SismicaMomento Ultimo (Tn.m)=151Resistencia del concreto a los 28 dias f'c (kg/cm)=2100.5>