CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS 1 CUADRO DE MANDO PARA PUERTAS, PERSIANAS ENROLLABLES Y TOLDOS Cuadro de control monofásico de 220 V AC para puertas, persianas enrollables y toldos, con receptor incorporado multi marca y multi frecuencia RX-Multi integrado. Entradas de pulsador arriba/abajo configurables como hombre presente, orden directa o pulsador secuencial, entrada de seguridad, finales de carrera y pulsador secuencial. Con cierre automático disponible y entrada de fotocélula. CONEXIONES

Upload: others

Post on 28-Dec-2019

24 views

Category:

Documents


2 download

TRANSCRIPT

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

1

CUADRO DE MANDO PARA PUERTAS,

PERSIANAS ENROLLABLES Y TOLDOS

Cuadro de control monofásico de 220 V AC para puertas, persianas

enrollables y toldos, con receptor incorporado multi marca y multi frecuencia

RX-Multi integrado. Entradas de pulsador arriba/abajo configurables como

hombre presente, orden directa o pulsador secuencial, entrada de

seguridad, finales de carrera y pulsador secuencial. Con cierre automático

disponible y entrada de fotocélula.

CONEXIONES

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

2

CONFIGURACIÓN DIP

1 FC / HOMBRE PRESENTE

ON Pulsador Hombre presente (en bornes Común, Apertura y

Cierre).

OFF Finales de carrera (en bornes Común, Apertura y Cierre).

2 HOMBRE PRESENTE EN APERTURA (DIP 1 ON)

ON Para realizar la maniobra de apertura es necesario

mantener pulsado el emisor o pulsador PROG. Si no se mantiene,

la maniobra se detiene.

OFF Orden directa durante la apertura.

3 HOMBRE PRESENTE EN CIERRE (DIP1 ON)

ON Para realizar la maniobra de cierre es necesario mantener

pulsado el emisor o el pulsador PROG. Si no se mantiene, la

maniobra se detiene.

OFF Orden directa durante el cierre.

4 FOTOCÉLULA

ON Inhabilita la fotocélula (No es necesario puentear la entrada

de Seguridad). Con esta configuración el cierre automático no

está disponible en la programación.

OFF Habilita la fotocélula para su conexión. Mediante

programación se puede configurar el modo automático.

PROGRAMACIÓN

MENÚ DE PROGRAMACIÓN

OPCIÓN 1 - MODO MEMORIZACIÓN DE MANDOS

Pulsar PROG hasta escuchar 1 pitido que indica que se ha

seleccionado el modo memorización para programar un emisor.

OPCIÓN 2 - MODO PROGRAMACIÓN TIEMPO MANIOBRAS

Pulsar PROG hasta escuchar 2 pitidos indicando que está en modo

programación de tiempos de maniobra. Donde se configura el

recorrido de la puerta.

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

3

OPCIÓN 3 - BORRADO DE CANAL

Pulsar PROG hasta escuchar 3 pitidos que indican que está en modo

borrado de canal grabado. Se borrará el canal y sonará un pitido de

confirmación.

OPCIÓN 4 - (DIP 1 ON) OPCIÓN 4 - (DIP 1 OFF)

UP-DOWN/PULSADOR SECUENCIAL

Pulsar PROG hasta escuchar 4

pitidos que indican opción

up/down, al soltar el botón, se

cambiará automáticamente a

pulsador secuencial y vice-versa.

Un pitido corto indica la selección

up/down, uno largo pulsador

secuencial.

PASO A PASO/INVERSIÓN CIERRE

Pulsar PROG hasta escuchar 4

pitidos indicando que se

encuentra en la opción inversión

al cierre. Al soltar el botón pasará

automáticamente al mo-do

inversión al cierre y viceversa.

Un pitido corto indica la

selección paso a paso, uno largo

inversión al cierre.

OPCIÓN 5 - BORRADO DE MEMORIA

Pulsar PROG hasta escuchar 5 pitidos que indican que está en modo

borrado de todos los canales y de mandos. Se borrará al soltar el

pulsador.

*Nota: una vez borrada la memoria hay que repetir la opción 1 y 2

OBLIGlATORIAMENTE para el correcto funcionamiento.

MEMORIZACIÓN MANDOS

Seleccionar la opción 1 del MENÚ: Pulsar PROG hasta escuchar 1 pitido que

indica que se encuentra en modo memorización.

Pulse el botón del mando que quiera utilizar, tres pitidos cortos confirmarán la

memorización.

El cuadro sale automáticamente del modo memorización una vez

transcurridos 4 segundos, o bien pulsando de nuevo el botón PROG o

pulsando un mando ya programado anteriormente, la salida se indica con

3 pitidos.

PROGRAMACIÓN DE TIEMPOS DE MANIOBRA

Antes de iniciar la programación, comprobar que los finales de carrera

están bien instalados (en caso de que se instalen). La puerta debe estar

cerrada.

Las ordenes se realizan mediante pulsación de PROG o de un mando

previamente programado.

1. Seleccionar la opción 2 del MENÚ: Pulsar PROG hasta escuchar 2

pitidos (Se ha activado el modo programación de tiempos de

maniobra).

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

4

2. La puerta comenzará la maniobra de apertura. Si se han

seleccionado los finales de carrera, parará por el final de carrera de

apertura, si no, dar la orden al final de la maniobra.

3. Una vez finalizada la maniobra de apertura, el cuadro espera una

orden para comenzar la maniobra de cierre. Si se da la orden dentro

de un intervalo de 5 segundos, se activa el modo manual; si se activa

pasados esos 5 segundos, se configura el modo de cierre

automático y el tiempo transcurrido desde el final de la maniobra de

apertura hasta que se inicia la maniobra de cierre es el tiempo de

pausa establecido.

*En el caso de que la fotocélula esté DESHABILITADA (DIP 4 ON):

No funciona la programación por cierre automático, solo

manual(por motivos de seguridad).

*En el caso de que la fotocélula esté HABILITADA, pero el usuario

no la instale: La placa se bloquea y no permite realizar ninguna

maniobra de cierre, indicando que hay un error en la

configuración.

4. La puerta se detendrá si los finales de carrera están instalados, por

contacto del final de carrera de cierre. Se escuchará un pitido para

indicar el fin de la maniobra de cierre y la salida de la programación

de tiempos de maniobra.

Repetir el procedimiento si se desea modificar la programación.

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

5

ROLLER SHUTTERS, DOORS AND

AWNINGS CONTROL BOARD

Control single-phase box for door, roller shutter and awnings, designed for

tubular motor. The power supply is 220 V AC. With receiver multibrand and

multifrequency RX-Multi integrated, up/down switch input (configurable as

dead man, direct order or sequencial switch), limit switches and sequencial

switch. Photobeam security signal input available and automatic

programmable closure.

CONNECTIONS

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

6

SETTING DIP CONFIGURATION

1 LIMIT SWITCHES /DEAD MAN

ON Dead man (for terminal Common, Open and Close).

OFF Limit switches (for terminal Common, Open and Close).

2 DEAD MAN IN OPENING MANEUVER (DIP 1 ON)

ON To start the opening maneuver, press the transmitter or the

switch. If the button is not held, the maneuver stops.

OFF Opening is set as direct order operation.

3 DEAD MAN IN CLOSING MANEUVER (DIP1 ON)

ON To start the closing maneuver, press the transmitter or the

PROG button. If the button is not held, the maneuver stops.

OFF Closing is set as direct order operation.

4 PHOTOBEAM

ON Photocell is disabled (It is not neccessary to

bridge the security input). Automatic closure is not available at

this position.

OFF Photobeam is enabled. This configuration allows the

programmation of optional automatic closure.

PROGRAMMATION

PROGRAMATION MENU

OPTION 1 – REMOTE MEMORIZATION MODE

Press PROG until 1 beep sounds that means remote memorization mode is

activated. Now you can learn the remote.

OPTION 2 - MANEUVERS TIME PROGRAMMING

Press PROG until 2 beeps sound that means it is on maneuvers time

programming.

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

7

OPTION 3 - CHANNEL ERASE

Press PROG until 3 beeps sound that means it is on delete of learnt

channel.

OPTION 4 (DIP 1 ON) OPTION 4 (DIP 1 OFF)

UP-DOWN / SEQUENTIAL SWITCH

Press PROG until 4 beeps sound that

means up/down option. When the

button is realised, menu changes to

alter switch and viceversa.

One long beep means alter switch

and a short beep means up/down

selection.

STEP BY STEP/INVERSION TO CLOSURE

Press PROG until 4 beeps sound that

means it is selected inversion to

closure option menu. When the

button is realised, menu changes to

inversion to closure and viceversa.

One long beep means inversion to

closure selection and a short beep

means step by ste

OPTION 5 –ERASE MEMORY

Press PROG until 5 beeps sound that selects channels and remotes delete

mode. Release to delete.

*Note: once the memory have been deleted, you have to repeat again the

option 1 and 2 obligatorily for correct working.

REMOTE LEARNING

Select option 1 from the MENU (Press PROG until 1 beep sounds that means it

is on remote memorization mode).

Press the button on the remote that you want to use, 3 short beeps will confirm

it is memorized correctly.

Control board ends the memorization mode by pressing again button PROG,

a remote previously learnt or after 4 seconds, 3 beeps indicate when it is out.

MANEUVERS TIME PROGRAMMING

Before programming, check limit switches in case they are installed. The door

should be closed.

The orders are given by pressing the remote previously installed or the PROG

button.

1. Select Option 2 from the MENU (Press PROG until 2 beeps sound this

means maneuver programming starts).

2. The opening maneuver starts. If limit switches have been installed,

maneuver ends by the opening limit switch contact, if not, the order must

be given at the end of the maneuver.

3. Control board awaits for the starting of closure maneuver. If it is activated

within 5 seconds, manual mode will be activated; if it is pressed after that 5

seconds, automatic closing mode will be set, the time spent from the end

of opening to closing maneuver starts, it is the pause time programmed.

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

8

*In case photobeam is DISABLED (DIP 4 ON): The automatic closure is

not available at programming maneuver option from the menu (for

security issues).

*In case photobeam is ENABLED (DIP 4 ON) but not installed by the user:

No closure will be made, so the user can notice the configuration is

mistaken. And the door can not work.

4. If limit switches have been installed door stops by closing limit switch

contact. If not, an order is required. A beep indicates the end of closing

maneuver and maneuver time programming finishes.

Repite the procedure if the maneuvers are not programmed correctly.

ITEM DIP POSITION COMPATIBLE

BRAND

FREQUEN

CY COMMENTS

1

ABC remote 433.92

MHz

2

Clemsa

Mastercode

433.92

MHz

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

9

3

DOOYA 433.92

MHz

4

FAAC SLH

Rolling Code

433.92

MHz

5

FAAC SLH 868.3 MHz

6

Hormann

Marantec

Berner

868.3 MHz

7

Jolly Motors 433.92

MHz

8

Liftmaster 315 MHz

9

Liftmaster 390 MHz

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

10

10

Liftmaster

Rolling Code

BillionCode

390 MHz

11

Liftmaster 433.92

MHz

12

Liftmaster

Rolling Code 868.3 MHz

13

Marantec 433.92

MHz

14

NICE FLORS 433.92

MHz

15

Prastel 433.92

MHz

16

Somfy 433.42

MHz

17

Sommer 433.4 MHz

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

11

18

Sommer

868.81

MHz

19

Universal

Fixed Code

Código Fijo

433.92

MHz Fixed Code

20

Universal

Rolling Code

Rolling Code

433.92

MHz Rolling Code

21

Universal

Rolling Code

868.3 MHz Rolling Code

22

Universal

Fixed Code

Código Fijo

300 MHz Fixed Code

23

Universal

Fixed Code

Código Fijo

310 MHz Fixed Code

24

Universal

Fixed Code 315 MHz Fixed Code

25

Universal

Fixed Code 318 MHz Fixed Code

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

12

26

Universal

Fixed Code 330 MHz Fixed Code

27

Universal

Fixed Code 390 MHz Fixed Code

28

Universal

Roling Code

Open Code

315 MHz Rolling Code

29

Universal

Rolling

Open Code

318 MHz Rolling Code

30

V2 433.92

MHz

31

V2 315 MHz

32

V2 390 MHz

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

13

33

DITEC 433.92

MHz

34

DITEC 315 MHz

35

DITEC 390 MHz

36

Aprimatic 433.92

MHz

37

Aprimatic 868.3 MHz

FSK

38

JCM TECH

868.3 MHz

39

JCM GO 868.3 MHz

CHAMELEON R+A: ROLLER SHUTTERS, DOORS AND AWNINGS

14

40

P.N.C. 868.3 MHz

41

MAP 868.3 MHz

42

Forsa 868.3 MHz

43

Alma 868.3 MHz