cables elÉctricos de cobre con aislamiento thw (75c)

Post on 16-Dec-2015

224 Views

Category:

Documents

8 Downloads

Preview:

Click to see full reader

DESCRIPTION

CABLES ELÉCTRICOS DE COBRE CON AISLAMIENTO THW (75C)

TRANSCRIPT

LINEAS220127Volts,3 FVolts,1 FCABLES ELCTRICOS DE COBRE CON AISLAMIENTO THW (75C)1330Por Roberto Ruelas Gmez. Ruel SA (Ingeniera) - 060329AmperesAmperesLARGO MAXLARGO MAXTAMAOTAMAOCONDUCTORCONDUCTORCONDUCTORCONDUCTOR(M)(M)NOMINALNOMINALTHW, THHWTHWNTHW, THHWTHWNCABLES ENCABLES ENAREAAREAAREADIMETRODIMETRO________ohm/km_________I max cc @CONDUITCONDUITTHWCON FORROCON FORROCOBRECON FORROCON FORROAMPACIDADTERMOMAGAMPACIDADTERMOMAGAMPACIDADTERMOMAGR (CD)R (CD)ZXl PVCXl Fe0.034METALICOMETALICOAWGmm2mm2mm2mm2mmmmAL AIREMAXCHR - AGRUPMAXEN CANALZMAXohm/km(1)(T1.4a)(NEC T9)(NEC T9)seg falla0.030.03NOM T10-8NOM T10-5NOM T10-5NOM T10-8NOM T10-5NOM T10-5(T310-17)NOM 240-6(T-A-310-2)NOM 240-6(T310-16)NOM 240-6NOM T10-8(2)DE CAIDADE CAIDA180.82351.0726.1161.3071.7016.4142.089.06.32.703.382.821515151510.38.45008.45000.1902880.239501104334.697.51123.3111.78.64.293.863.31202020206.505.32005.32000.1771650.223097165755.1011.94105.2615.713.66.824.474.16303030304.073.34003.34000.1640420.206692263587.7619.0188.3728.223.610.85.995.486060576040402.552.10002.10000.1706030.2132544192139.5830.24613.3046.832.717.27.726.458080768055601.621.32001.32000.1673220.2099736664222.0648.11421.1562.853.227.38.948.2312512510112570701.010.83200.83200.1574800.19685010597352.3176.32233.6286.074.743.210.59.751702001351501151250.6360.52300.52300.1476370.18700716845560.47121.41053.4814312070.113.512.42302501832001501500.40.32900.32930.1443560.18044626796890.07192.820067.4316914388.514.713.52653002122251751750.3170.26100.26130.1410760.177165337851121.96243.0500085.0120117311216.014.83103502452502002000.2520.20700.20740.1377950.170603425941413.24306.150000107.2024020914117.516.33604002873002302500.1990.16400.16470.1345140.167322537121780.23385.65250126.6729725616819.418.14054503203502553000.1690.13900.13970.1345140.170603634672098.32454.56300152.0134129720120.819.44454503594002853000.1410.11600.11670.1345140.167322761632511.87544.15350177.3438433823522.120.75056003974003103500.120.09920.1312330.16404288855400202.6842737826923.321.95456004304503353500.1050.08680.08780.1312330.1607611015513340.27723.61500253.3551045633525.524.16207004965003804000.08460.06940.07060.1279820.1574801269394149.02898.81600304.0262856040428.326.76907005536004204500.07020.05790.1279820.157480152327750380.0375267750530.929.47858006387004755000.05610.04630.04810.1246720.1574801904116093.351320.011000506.7195487067234.933.39358007488005456000.04230.03470.03700.1213910.1509182538837916.971715.06FACTOR DE AGRUPAMIENTO F.A.FACTOR DE TEMPERATURA F.T.No. Cond(T310-16)Temp C(T310-17)1-31.0021-251.054-60.8026-3017-90.7031-350.9410-200.5036-400.8821-300.4541-450.8231-400.4046-500.7541-0.3551-550.6756-600.5861-700.33NOTAS(1) Referencia: Condumex. Manual del Electricista.(2) Segn la frmula considerando temperatura mx operacin 75 C y de cortocircuito 150 C. Se puede cambiar el tiempo del cortocircuito

top related