Documento 1.2
Cálculos
PROYECTO FIN
DE CARRERA
PLANTA DE GENERACIÓN DE ENERGÍA
ELÉCTRICA A PARTIR DE BIOMASA CON
UNA POTENCIA DE 2MW
Marzo 2011
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
1/106
ÍNDICE ....................................................................................................................................................... 1
1 CÁLCULOS DEL SISTEMA DE OBTENCIÓN DE ENERGÍA ................................................ 3
1.1 CICLO DE RANKINE ...................................................................................................................... 3 1.2 RESULTADOS DEL CÁLCULO TERMODINÁMICO ................................................................................ 5
1.2.1 Balance de materia .......................................................................................... 7 1.2.2 Balance de energía .......................................................................................... 7
1.3 ANÁLISIS DE LOS COMPONENTES DEL CICLO DE VAPOR .................................................................. 7
1.3.1 Caldera ........................................................................................................... 8 1.3.2 Turbina de vapor ............................................................................................. 8 1.3.3 Condensador ................................................................................................... 8 1.3.4 Torres de refrigeración ..................................................................................... 9 1.3.5 Desgasificador ............................................................................................... 10 1.3.6 Bombas......................................................................................................... 10 1.3.7 Alimentación de aire ...................................................................................... 10 1.3.8 Alimentación de combustible .......................................................................... 11 1.3.9 Salida de gases ............................................................................................. 11 1.3.10 Splitter (separador de corrientes) ................................................................... 11
1.4 ANÁLISIS DE LAS CORRIENTES .................................................................................................... 11
1.4.1 Corrientes de aire y gases .............................................................................. 11 1.4.2 Corrientes de agua líquida y vapor .................................................................. 12 1.4.3 Corrientes de combustible .............................................................................. 12
1.5 CANTIDAD DE BIOMASA NECESARIA Y ALMACENAMIENTO DE LA MISMA ......................................... 13
2 CÁLCULOS ESTRUCTURALES ................................................................................................ 15
2.1 NAVE ALMACÉN ......................................................................................................................... 15
2.1.1 Estructura ..................................................................................................... 15 2.1.2 Cimentación .................................................................................................. 32
2.2 NAVE DE PROCESO .................................................................................................................... 42
2.2.1 Estructura ..................................................................................................... 42 2.2.2 Cimentación .................................................................................................. 72
3 CÁLCULO DEL SISTEMA CONTRA INCENDIOS ................................................................. 87
3.1 CARACTERIZACIÓN ..................................................................................................................... 87
3.1.1 Configuración ................................................................................................ 87 3.1.2 Carga de fuego de las áreas de incendio ......................................................... 87
3.2 SECTORIZACIÓN ........................................................................................................................ 99
3.2.1 Sectores de incendio ...................................................................................... 99 3.2.2 Nivel de riesgo del establecimiento ............................................................... 100
3.3 INSTALACIONES NECESARIAS .................................................................................................... 100
3.3.1 Hidrantes exteriores ..................................................................................... 101 3.3.2 Red de bocas de incendio equipadas (BIEs) .................................................. 101 3.3.3 Rociadores automáticos ............................................................................... 101 3.3.4 Columna seca .............................................................................................. 101 3.3.5 Sistema de abastecimiento de agua y grupo de bombeo ................................ 101
Índice
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
2/106
3.3.6 Extintores de incendio .................................................................................. 102 3.3.7 Detectores automáticos................................................................................ 102 3.3.8 Sistemas manuales de alarma de incendios ................................................... 102 3.3.9 Estabilidad al fuego de los elementos constructivos portantes ........................ 102 3.3.10 Evacuación .................................................................................................. 104
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
3/106
1.1 Ciclo de Rankine
El fundamento termodinámico que emplea la planta para la generación del
trabajo, transformable en energía eléctrica por el generador, se basa en el ciclo
termodinámico de Rankine. Dicho ciclo se trata de un ciclo agua-vapor
caracterizado por dos procesos isóbaros y otros dos isentrópicos, como
podemos ver en la siguiente figura:
Fig. 1: Ciclo de Rankine
1
1 Cálculos del sistema de obtención de energía
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
4/106
El anterior se trata del ciclo ideal, es decir, el que seguiría el sistema si los
rendimientos de los todos equipos fuesen del 100% y las pérdidas de calor en
todo el circuito agua-vapor fuesen nulas.
A continuación analizamos los puntos de trabajo representativos del ciclo
real con el que trabajará la planta:
PUNTO 1
Vapor sobrecalentado
T (ºC) 450
P (bar) 40
H (kJ/kg) 3331,01
S (J/kg ºC) 6,9388
PUNTO 2
Vapor húmedo
T (ºC) 45,83
P (bar) 0,1
H (kJ/kg) 2326,69
S (J/kg ºC) 8,1511
PUNTO 3
Líquido saturado
T (ºC) 45,83
P (bar) 0,1
H (kJ/kg) 191,82
S (J/kg ºC) 0,6492
PUNTO 4
Líquido subenfriado
T (ºC) 45,85
P (bar) 1,196
H (kJ/kg) 192,00
S (J/kg ºC) 0,6494
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
5/106
1.2 Resultados del cálculo termodinámico
Para la resolución de todos los cálculos termodinámicos necesarios hemos
empleado el programa informático THERMOFLEX, uno de los subprogramas
perteneciente al grupo THERMOFLOW. En dicho programa hemos modelado el
ciclo de Rankine con todos sus componentes, dando como datos de partida el
rendimiento de todos los equipos, la presión y temperatura de vapor vivo, y el
caudal de vapor necesario para la generación de 2 MWe. A continuación
mostramos el esquema del ciclo Rankine resuelto por el programa:
Fig. 2: Modelado del ciclo con Thermoflex
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
6/106
A continuación mostramos los resultados generales obtenidos con dicho
programa:
PCI PCS
Potencia de entrada neta de combustible (kW) 7235 7796
Tasa bruta de calor (kJ/kWh) 13023
Tasa neta de calor (kJ/kWh) 13841 14915
Eficiencia eléctrica bruta (%) 27,64
Eficiencia eléctrica neta (%) 26,01 24,14
Potencia bruta 2000
Potencia neta 1901,8
Potencia auxiliar total 98,2
• Equipos generadores de energía eléctrica:
Potencia en el eje (kW) Eficiencia (%) Salida (kW)
Turbina de vapor 2083,7
Generador 2083,7 95,98 2000
• Equipos consumidores de energía eléctrica (autoconsumo):
Potencia en el eje (kW) Eficiencia (%) Potencia consumida (kW)
Torres de refrigeración 48,1
Caldera 19,1
Bomba 1 15,8 91,07 17,3
Bomba 2 0,4 98,52 0,4
Condensador 13,4
Total 98,2
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
7/106
1.2.1 Balance de materia
Caudal másico de entrada (kg/s) Caudal másico de salida (kg/s)
Combustible de entrada 0,43
Aire de entrada 2,51
Salida de gases 2,94
TOTAL 2,94 2,94
1.2.2 Balance de energía
Energía suministrada (KW) Energía cedida (KW)
Torres de refrigeración 4.439,00
Combustible de entrada 7.235,00
Salida de gases 539,20
Turbina de vapor 2.087,80
Bomba 1 0,37
Bomba 2 15,31
Caldera 17,32 202,00
TOTAL 7.268,00 7.268,00
1.3 Análisis de los componentes del ciclo de vapor
En este apartado mostramos los resultados obtenidos para cada uno de
los equipos que componen el ciclo agua-vapor de Rankine:
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
8/106
1.3.1 Caldera
Nº de
corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)
Aire de entrada 5 1,013 25 2,51 0
Combustible de entrada 4 1,013 25 0,429 16850,84
Salida de gases 7 1,013 194,51 2,936 183,68
Agua de entrada 13 42,44 100,51 2,24 -2123,08 424,41
Vapor de salida 8 40 450 2,24 783,52 3331,01
• Calor transferido:
Calor cedido en el economizador (kW) 1291,3
Calor cedido en el evaporador (kW) 4029
Calor cedido en el sobrecalentador (kW) 1190,3
Calor total transferido (kW) 6511
Perdidas de calor (kW) 201,4
1.3.2 Turbina de vapor
Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)
Agua de entrada 3 40 450 2,079 783,52 3331,01
Agua de salida 6 0,1 45,83 2,079 -220,7 2326,79
1.3.3 Condensador
Nº de corriente
P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
9/106
Vapor de entrada 6 0,1 45,83 2,079 -220,7 2326,79
Agua de salida 10 0,1 45,83 2,079 -2355,67 191,82
Entrada agua refrigeración 1 1,013 29,48 106,615 -2423,8 123,69
Salida agua refrigeración 11 1,013 39,48 106,615 -2382,16 165,32
1.3.4 Torres de refrigeración
Nº de corriente
P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)
Agua de entrada 11 1,013 39,48 106,615 -2382,16 165,32
Agua de salida 1 1,013 29,48 106,615 -2423,8 123,69
Aire de entrada 25 253,253
Aire de salida 25,11 255,073
• Balance de materia en las torres:
Purgas (kg/s) 0,4336
Derivaciones (kg/s) 0,02132
Evaporada (kg/s) 1,82
Entrada desde depósito (kg/s) 2,275
• Consumo de energía eléctrica en las torres:
Potencia consumida (kW)
Bombas 13,38
Ventiladores 34,7
TOTAL 48,08
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
10/106
1.3.5 Desgasificador
Nº de
corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)
Agua de entrada 9 1,196 45,85 2,079 -2355,49 192
Vapor de entrada 12 40 450 0,161 783,52 3331,01
Agua de salida 2 1,196 99,63 2,24 -2129,91 417,58
1.3.6 Bombas
• Bomba de baja presión:
Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)
Agua de entrada 10 0,1 45,83 2,079 -2355,67 191,82
Agua de salida 9 1,196 45,85 2,079 -2355,49 192
• Bomba de alta presión:
Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)
Agua de entrada 2 1,196 99,63 2,24 -2129,91 417,58
Agua de salida 13 42,44 100,51 2,24 -2123,08 424,41
1.3.7 Alimentación de aire
Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg)
Aire 5 1,013 25 2,511 0
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
11/106
1.3.8 Alimentación de combustible
Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg)
Combustible 4 1,013 25 0,492 16850,84
1.3.9 Salida de gases
Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg)
Gases 7 1,013 194,51 2,936 183,68
1.3.10 Splitter (separador de corrientes)
Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)
Agua de entrada 8 40 450 2,24 783,52 3331,01
Agua de salida 1 3 40 450 2,079 783,52 3331,01
Agua de salida 2 12 40 450 0,161 783,52 3331,01
1.4 Análisis de las corrientes
En este apartado analizamos cada una de las corrientes que forman el
circuito:
1.4.1 Corrientes de aire y gases
Nº de corriente P (bar) T (ºC) H* (kJ/kg) Mgas (kg/s) Mash (kg/s) V (m3/s)
5 1,0132 25 0 2,511 0 2,1
7 1,0132 194,51 183,68 2,936 0,004 3,8
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
12/106
1.4.2 Corrientes de agua líquida y vapor
Nº de corriente P (bar) T (ºC) H* (kJ/kg) H (kJ/kg) M (kg/s) Sup/Sub
(ºC)
1 1,0132 29,48 -2423,8 123,69 106,6 -10,52
2 1,196 99,63 -2129,91 417,58 2,24 -5,09
3 40 450 783,52 3331,01 2,079 199,67
6 0,1 45,83 -220,7 2326,79 2,079 0,8922
8 40 450 783,52 3331,01 2,24 199,67
9 1,196 45,85 -2355,49 192 2,079 -58,87
10 0,1 45,83 -2355,67 191,82 2,079 0
11 1,0132 39,48 -2382,17 165,32 106,6 -60,52
12 40 450 783,52 3331,01 0,161 199,67
13 42,44 100,51 -2123,08 424,41 2,24 -153,35
1.4.3 Corrientes de combustible
Nº de corriente P (bar) T (ºC) H* (kJ/kg) M (kg/s) Cenizas (%) H2O (%)
4 1,0132 25 16850,84 0,429 1,08 5
Composición del combustible de entrada al ciclo:
% en peso de cenizas 1,08
% en peso de humedad 12
% en peso de C 45,41
% en peso de H 5,43
% en peso de O 42,56
% en peso de N 0,45
% en peso de S 0,07
PCI (kJ/kg) 16851
PCS (kJ/kg) 18158
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
13/106
1.5 Cantidad de biomasa necesaria y almacenamiento de la misma
La caldera de biomasa consume 0.429 kg/s de astillas de eucalipto
durante su funcionamiento, por lo que es necesario asegurar el abastecimiento
de la misma para evitar paradas en la producción. La planta estará
funcionando durante 7.500 horas al año, por lo que la demanda anual de
biomasa será:
año
ton
año
kg
h
s
año
h
s
kg115831158300036007500429.0 ==⋅⋅
En cuanto a las necesidades de almacenamiento, los requerimientos que
vamos a imponer al silo principal son que tenga suficiente capacidad para el
almacenamiento de astillas para el funcionamiento ininterrumpido de la planta
durante una semana. Por lo tanto la capacidad del silo principal, considerando
una densidad de la madera astillada de 300 kg/m3, ha de ser:
3
3
865300
3600247429.0m
m
kgh
s
día
hdías
s
kg
=⋅⋅⋅
Finalmente, la nave de almacenamiento debe tener una capacidad
suficiente para almacenar troncos de eucalipto para la producción
ininterrumpida durante una semana. Considerando una densidad de la madera
de 720 kg/m3, tenemos que el volumen de madera necesario es:
3
3
36.360720
3600247429.0m
m
kgh
s
día
hdías
s
kg
=⋅⋅⋅
Suponiendo un factor de apilamiento de los troncos de 0,7 tenemos que el
volumen necesario para el almacenamiento de los troncos es:
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
14/106
33 6137.036.360 mm =⋅
Suponiendo una altura de almacenamiento de 2 m, tenemos que la
superficie destinada al almacenamiento de los troncos a de ser:
23
5.3062
613m
m
m =
Puesto que la superficie de la Nave de Almacenamiento es 600 m2,
concluimos que ésta es lo suficientemente grande para cumplir los requisitos de
almacenamiento de troncos.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
15/106
2.1 Nave Almacén
2.1.1 Estructura
La estructura de la Nave Almacén se ha calculado empleando perfiles de
acero laminado S 275 JR. Está formada por 7 pórticos rígidos a un agua de 20
m de luz, con 8 m de altura en los pilares aguas abajo y 10 m en los pilares
aguas arriba, en todos los casos respecto a la solera terminada.
Los pilares irán empotrados en su base a la cimentación mediante placas
de anclaje, con una separación entre pórticos 5 m.
Las correas están formadas por perfiles laminados en caliente IPE 140
separados entre sí 1 m, que reciben la carga de la cubierta.
Fig. 3: Detalle de un pórtico intermedio y las correas
2
2 Cálculos estructurales
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
16/106
La tipología de la estructura se puede ver de una forma más clara en la
siguiente figura, en la que se muestra una representación 3D de la misma:
Fig. 4: Vista 3D de la estructura metálica
• Acciones adoptadas en el cálculo
Todos los valores de las acciones que se han aplicado en el cálculo de
cada uno de los elementos resistentes se ajustan a lo prescrito en la Norma
“CTE DB SE-AE Acciones en la Edificación”, siendo sus valores los siguientes:
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
17/106
Acciones Gravitatorias
Concargas Peso Propio
Cubierta de chapa: 15 kg/m²
Estructura: 7.850 kg/m³
Carga Permanente -
Sobrecargas De Uso 25 kg/m2
De Nieve H: 300 m 20 kg/m²
Acciones del Viento Según CTE DB SE-AE
Altura Coronación < 10 m. Situación Expuesta.
Acciones Térmicas No se necesitan juntas de dilatación
Acciones Reológicas
No han sido consideradas por tratarse de una estruc-tura toda ella realizada con materiales metálicos y
ser, por tanto, despreciables los efectos de las mismas, según indica la Norma CTE DB SE-A.
Acciones Sísmicas No han sido consideradas por ser la aceleración
básica menor que la mínima exigida para realizar los cálculos sísmicos según indica el CTE
El acero empleado en la estructura será del tipo S 275 JR con límite
elástico σe = 275 N/mm2, la estructura secundaria (correas) será del tipo S 275
JR con límite elástico σe = 275 N/mm2. La resistencia de cálculo del acero viene
fijada por la expresión: σu = σe / γa, donde γa es el coeficiente de minoración,
con valor 1, pues el acero tendrá el límite elástico mínimo garantizado.
Las constantes elásticas del acero serán las siguientes:
Módulo de elasticidad E = 2100000 kg/cm2
Módulo de elasticidad transversal G = 810000 kg/cm2
Coeficiente de Poisson µ = 0.30
El coeficiente de dilatación térmica del acero para el cálculo de esfuerzos,
tensiones y deformaciones se tomará: αt = 0.000012 m/m°C.
• Métodos de cálculo e hipótesis de carga
El cálculo se ha realizado mediante programa informático comercial
“METAL 3D” de la casa especializada “CYPE INGENIEROS, S.A.”,
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
18/106
comprobándose la estabilidad estática y elástica, las tensiones y las
deformaciones.
Dichos cálculos están basados en las leyes de la mecánica y en la teoría
de la elasticidad, admitiendo, en alguna ocasión y de modo implícito, la
existencia de estados tensionales plásticos locales.
Las hipótesis de carga utilizadas son las establecidas en el CTE DB SE-AE y
las acciones características las prescritas en el CTE DB SE-AE. Las acciones
consideradas en este cálculo han sido las siguientes:
Acciones constantes:
- el peso propio;
- la carga permanente;
Acciones variables:
- las sobrecargas de uso o explotación;
- las acciones de viento;
- la sobrecarga producida por la nieve;
Los coeficientes de ponderación según la hipótesis de carga, la clase de
acción y el efecto favorable o desfavorable de la acción sobre la estabilidad o
las tensiones se dan en el cuadro siguiente:
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
19/106
• Resultados en el cálculo de esfuerzos sobre la estructura
Se muestran a continuación los resultados del cálculo sobre la estructura
principal y correas. No se incluyen en estos listados los resultados sobre las
cruces de San Andrés.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
20/106
Resultados de cálculo en pórtico hastial 1.- Barras: Descripción
Barras Material Perfil Peso Volumen Longitud Co.pand.xy Co.pand.xz Dist.arr.sup. Dist.arr.inf.
(kp) (m³) (m) (m) (m)
53/54 Acero (S275) HE 220 A (HEA) 403.80 0.051 8.00 0.70 1.33 8.00 8.00
54/56 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
55/56 Acero (S275) HE 240 A (HEA) 504.91 0.064 8.38 0.70 1.30 8.38 8.38
56/58 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
57/58 Acero (S275) HE 240 A (HEA) 527.52 0.067 8.75 0.70 1.30 8.75 8.75
58/60 Acero (S275) IPE 160 (IPE) 79.29 0.010 5.02 0.05 0.73 1.00 5.02
59/60 Acero (S275) HE 240 A (HEA) 557.66 0.071 9.25 0.70 1.30 9.25 9.25
60/62 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
61/62 Acero (S275) HE 240 A (HEA) 580.27 0.074 9.63 0.70 1.30 9.63 9.63
62/64 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
63/64 Acero (S275) HE 240 A (HEA) 602.88 0.077 10.00 0.70 1.28 10.00 10.00
2.- Cargas (Barras)
Barras Hipót. Tipo Cargas Dirección
P1 P2 L1 (m) L2 (m) X Y Z
53/54 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000
53/54 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
53/54 3 (V 1) Uniforme 0.152 t/m - - - 0.000 1.000 0.000
53/54 3 (V 1) Uniforme 0.175 t/m - - - 1.000 0.000 0.000
53/54 4 (V 2) Uniforme 0.152 t/m - - - 0.000 1.000 0.000
53/54 4 (V 2) Uniforme 0.175 t/m - - - 1.000 0.000 0.000
53/54 5 (V 3) Uniforme 0.104 t/m - - - 0.000 -1.000 0.000
53/54 5 (V 3) Uniforme 0.073 t/m - - - 1.000 0.000 0.000
53/54 6 (V 4) Uniforme 0.076 t/m - - - 0.000 -1.000 0.000
53/54 6 (V 4) Uniforme 0.117 t/m - - - 1.000 0.000 0.000
53/54 7 (V 5) Uniforme 0.248 t/m - - - 0.000 -1.000 0.000
53/54 7 (V 5) Uniforme 0.117 t/m - - - -1.000 0.000 0.000
54/56 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
54/56 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
54/56 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
54/56 3 (V 1) Faja 0.120 t/m - 2.010 3.769 0.000 -0.100 0.995
54/56 3 (V 1) Trapez. 0.340 t/m 0.340 t/m 0.000 2.010 0.000 -0.100 0.995
54/56 4 (V 2) Faja 0.003 t/m - 2.010 3.769 0.000 0.100 -0.995
54/56 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 2.010 0.000 0.100 -0.995
54/56 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
54/56 6 (V 4) Uniforme 0.167 t/m - - - 0.000 -0.100 0.995
54/56 7 (V 5) Uniforme 0.342 t/m - - - 0.000 -0.100 0.995
54/56 7 (V 5) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
54/56 8 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
54/56 9 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
55/56 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
55/56 3 (V 1) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
55/56 4 (V 2) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
21/106
55/56 5 (V 3) Uniforme 0.146 t/m - - - 1.000 0.000 0.000
55/56 6 (V 4) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
55/56 7 (V 5) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
56/58 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
56/58 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
56/58 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
56/58 3 (V 1) Uniforme 0.120 t/m - - - 0.000 -0.100 0.995
56/58 4 (V 2) Uniforme 0.003 t/m - - - 0.000 0.100 -0.995
56/58 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
56/58 6 (V 4) Uniforme 0.167 t/m - - - 0.000 -0.100 0.995
56/58 7 (V 5) Faja 0.342 t/m - 0.000 1.256 0.000 -0.100 0.995
56/58 7 (V 5) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
56/58 7 (V 5) Trapez. 0.299 t/m 0.299 t/m 1.256 3.769 0.000 -0.100 0.995
56/58 8 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
56/58 9 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
57/58 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
57/58 3 (V 1) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
57/58 4 (V 2) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
57/58 5 (V 3) Uniforme 0.170 t/m - - - 1.000 0.000 0.000
57/58 6 (V 4) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
57/58 7 (V 5) Uniforme 0.273 t/m - - - -1.000 0.000 0.000
58/60 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
58/60 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
58/60 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
58/60 3 (V 1) Uniforme 0.120 t/m - - - 0.000 -0.100 0.995
58/60 4 (V 2) Uniforme 0.003 t/m - - - 0.000 0.100 -0.995
58/60 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
58/60 6 (V 4) Uniforme 0.167 t/m - - - 0.000 -0.100 0.995
58/60 7 (V 5) Uniforme 0.299 t/m - - - 0.000 -0.100 0.995
58/60 7 (V 5) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
58/60 8 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
58/60 9 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
59/60 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
59/60 3 (V 1) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
59/60 4 (V 2) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
59/60 5 (V 3) Uniforme 0.170 t/m - - - 1.000 0.000 0.000
59/60 6 (V 4) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
59/60 7 (V 5) Uniforme 0.273 t/m - - - -1.000 0.000 0.000
60/62 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
60/62 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
60/62 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
60/62 3 (V 1) Uniforme 0.120 t/m - - - 0.000 -0.100 0.995
60/62 4 (V 2) Uniforme 0.003 t/m - - - 0.000 0.100 -0.995
60/62 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
60/62 6 (V 4) Uniforme 0.167 t/m - - - 0.000 -0.100 0.995
60/62 7 (V 5) Faja 0.299 t/m - 0.000 2.513 0.000 -0.100 0.995
60/62 7 (V 5) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
22/106
60/62 7 (V 5) Trapez. 0.351 t/m 0.351 t/m 2.513 3.769 0.000 -0.100 0.995
60/62 8 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
60/62 9 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
61/62 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
61/62 3 (V 1) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
61/62 4 (V 2) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
61/62 5 (V 3) Uniforme 0.146 t/m - - - 1.000 0.000 0.000
61/62 6 (V 4) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
61/62 7 (V 5) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
62/64 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
62/64 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
62/64 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
62/64 3 (V 1) Uniforme 0.120 t/m - - - 0.000 -0.100 0.995
62/64 4 (V 2) Uniforme 0.003 t/m - - - 0.000 0.100 -0.995
62/64 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
62/64 6 (V 4) Faja 0.167 t/m - 0.000 1.759 0.000 -0.100 0.995
62/64 6 (V 4) Trapez. 0.479 t/m 0.479 t/m 1.759 3.769 0.000 -0.100 0.995
62/64 7 (V 5) Uniforme 0.351 t/m - - - 0.000 -0.100 0.995
62/64 7 (V 5) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
62/64 8 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
62/64 9 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
63/64 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
63/64 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
63/64 3 (V 1) Uniforme 0.076 t/m - - - 0.000 1.000 0.000
63/64 3 (V 1) Uniforme 0.117 t/m - - - 1.000 0.000 0.000
63/64 4 (V 2) Uniforme 0.076 t/m - - - 0.000 1.000 0.000
63/64 4 (V 2) Uniforme 0.117 t/m - - - 1.000 0.000 0.000
63/64 5 (V 3) Uniforme 0.104 t/m - - - 0.000 1.000 0.000
63/64 5 (V 3) Uniforme 0.073 t/m - - - 1.000 0.000 0.000
63/64 6 (V 4) Uniforme 0.152 t/m - - - 0.000 -1.000 0.000
63/64 6 (V 4) Uniforme 0.175 t/m - - - 1.000 0.000 0.000
63/64 7 (V 5) Uniforme 0.248 t/m - - - 0.000 1.000 0.000
63/64 7 (V 5) Uniforme 0.117 t/m - - - -1.000 0.000 0.000 3.- Desplazamientos
Nudos Descripción DESPLAZAMIENTOS (EJES GENERALES)
DX (m) DY (m) DZ (m) GX (rad) GY (rad) GZ (rad)
53 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
54 Envolvente (Desplazam.) -0.0176 -0.0277 0.0000 -0.0017 -0.0013 -0.0013
0.0176 0.0186 0.0000 0.0033 0.0001 0.0017
55 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
56 Envolvente (Desplazam.) -0.0306 -0.0277 -0.0001 -0.0010 -0.0037 -0.0014
0.0305 0.0186 0.0000 0.0014 0.0026 0.0013
57 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
23/106
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
58 Envolvente (Desplazam.) -0.0412 -0.0277 -0.0001 -0.0015 -0.0057 -0.0018
0.0411 0.0186 0.0000 0.0019 0.0033 0.0014
59 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
60 Envolvente (Desplazam.) -0.0453 -0.0278 -0.0001 -0.0009 -0.0058 -0.0017
0.0451 0.0186 0.0000 0.0015 0.0032 0.0014
61 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
62 Envolvente (Desplazam.) -0.0383 -0.0278 -0.0001 -0.0009 -0.0037 -0.0017
0.0382 0.0186 0.0000 0.0015 0.0023 0.0012
63 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
64 Envolvente (Desplazam.) -0.0257 -0.0278 -0.0001 -0.0012 -0.0019 -0.0013
0.0256 0.0186 0.0000 0.0031 0.0004 0.0017 4.- Reacciones
Nudos Descripción REACCIONES (EJES GENERALES)
RX (t) RY (t) RZ (t) MX (t�m) MY (t�m) MZ (t�m)
53 Envolvente (Cim.equil.) -1.2011 -1.4993 -0.5265 -3.8632 -1.7118 -0.0008
1.0275 1.9856 1.5077 3.7367 2.1021 0.0006
53 Envolvente (Cim.tens.terr.) -0.7511 -0.9320 -0.0205 -2.4335 -1.0708 -0.0005
0.6409 1.2489 1.0277 2.3236 1.3102 0.0004
55 Envolvente (Cim.equil.) -2.2464 -0.2738 -1.5184 -1.9010 -6.7868 -0.0009
2.6694 0.4179 2.5817 1.2559 7.5018 0.0008
55 Envolvente (Cim.tens.terr.) -1.4661 -0.1727 -0.5193 -1.1844 -4.4126 -0.0005
1.6093 0.2601 1.7922 0.7902 4.5263 0.0006
57 Envolvente (Cim.equil.) -3.0455 -0.2179 -1.8951 -1.6433 -8.5896 -0.0009
3.2301 0.3333 3.3033 1.0832 9.3926 0.0010
57 Envolvente (Cim.tens.terr.) -2.0046 -0.1338 -0.6569 -1.0372 -5.6594 -0.0005
1.9243 0.2121 2.3030 0.6706 5.5985 0.0007
59 Envolvente (Cim.equil.) -3.0732 -0.2126 -1.7578 -1.5542 -8.8265 -0.0009
3.2838 0.3083 3.2966 1.0582 9.7271 0.0009
59 Envolvente (Cim.tens.terr.) -2.0129 -0.1370 -0.5657 -0.9625 -5.7970 -0.0005
1.9663 0.1900 2.2937 0.6748 5.8171 0.0006
61 Envolvente (Cim.equil.) -2.3403 -0.1825 -1.1609 -1.3759 -7.2252 -0.0007
2.7857 0.2555 2.6294 0.9555 8.1699 0.0009
61 Envolvente (Cim.tens.terr.) -1.5114 -0.1138 -0.2767 -0.8610 -4.6704 -0.0004
1.6946 0.1602 1.8217 0.5968 4.9589 0.0006
63 Envolvente (Cim.equil.) -1.5057 -2.2201 -1.0325 -5.7841 -2.6881 -0.0009
1.2454 1.9123 1.8848 3.6846 3.0679 0.0007
63 Envolvente (Cim.tens.terr.) -0.9414 -1.3951 -0.2428 -3.5976 -1.6811 -0.0006
0.7772 1.1903 1.2792 2.3291 1.9135 0.0004 5.- Esfuerzos
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
24/106
Barras Esf. ESFUERZOS (EJES LOCALES) (t)(t�m)
0 L 1/8 L 1/4 L 3/8 L 1/2 L 5/8 L 3/4 L 7/8 L 1 L
53/54 0.000 m 1.000 m 2.000 m 3.000 m 4.000 m 5.000 m 6.000 m 7.000 m 8.000 m
Envolvente (Acero laminado)
N- -1.3672 -1.2653 -1.1634 -1.0615 -0.9596 -0.8578 -0.7559 -0.6540 -0.5521
N+ 0.6067 0.6671 0.7275 0.7878 0.8482 0.9086 0.9690 1.0294 1.0897
Ty- -0.9638 -0.7883 -0.6128 -0.4373 -0.2618 -0.1896 -0.4521 -0.7146 -0.9771
Ty+ 1.1259 0.8634 0.6009 0.3649 0.2513 0.1418 0.0915 0.2670 0.4425
Tz- -1.8608 -1.4881 -1.1154 -0.7463 -0.5843 -0.4704 -0.3566 -0.2853 -0.4873
Tz+ 1.4074 1.1797 0.9519 0.7242 0.4964 0.2687 0.3993 0.7720 1.1446
Mt- -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006
Mt+ 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007
My- -3.6200 -2.6394 -1.7681 -1.0299 -0.5957 -0.9250 -1.0356 -0.9094 -0.5645
My+ 3.5075 2.2185 1.1482 0.5630 1.0720 1.2483 1.0667 0.8665 1.0545
Mz- -1.9721 -1.0995 -0.3954 -0.5869 -0.7992 -0.7386 -0.5733 -0.5486 -0.4188
Mz+ 1.6042 0.9589 0.4317 0.1522 0.4792 0.6498 0.6519 0.4714 1.0134
54/56 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.4773 -0.4670 -0.4567 -0.4465 -0.4362 -0.4259 -0.4157 -0.4055 -0.4009
N+ 1.1602 1.1634 1.1666 1.1698 1.1730 1.1762 1.1794 1.1827 1.1915
Ty- -0.0541 -0.0541 -0.0541 -0.0541 -0.0541 -0.0541 -0.0541 -0.0541 -0.0541
Ty+ 0.0677 0.0677 0.0677 0.0677 0.0677 0.0677 0.0677 0.0677 0.0677
Tz- -0.4932 -0.4653 -0.4807 -0.4961 -0.5263 -0.6123 -0.6983 -0.7844 -0.9393
Tz+ 0.8811 0.6536 0.4305 0.2561 0.2905 0.3953 0.5000 0.6048 0.7095
Mt- -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004
Mt+ 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003
My- -1.0539 -0.8383 -0.6677 -0.4798 -0.2529 -0.2236 -0.2187 -0.4556 -0.7642
My+ 0.5643 0.3903 0.3530 0.2892 0.1941 0.1496 0.3483 0.6740 1.0629
Mz- -0.1067 -0.0812 -0.0559 -0.0305 -0.0052 -0.0259 -0.0578 -0.0897 -0.1216
Mz+ 0.1336 0.1017 0.0699 0.0382 0.0064 0.0207 0.0462 0.0717 0.0972
55/56 0.000 m 1.047 m 2.094 m 3.141 m 4.188 m 5.234 m 6.281 m 7.328 m 8.375 m
Envolvente (Acero laminado)
N- -2.3559 -2.2707 -2.1855 -2.1003 -2.0151 -1.9299 -1.8447 -1.7595 -1.6743
N+ 1.5810 1.6315 1.6820 1.7325 1.7830 1.8335 1.8840 1.9345 1.9850
Ty- -0.3921 -0.3921 -0.3921 -0.3921 -0.3921 -0.3921 -0.3921 -0.3921 -0.3921
Ty+ 0.2565 0.2565 0.2565 0.2565 0.2565 0.2565 0.2565 0.2565 0.2565
Tz- -2.0971 -1.7538 -1.5210 -1.2917 -1.0624 -0.8332 -0.6039 -0.4061 -0.6249
Tz+ 2.5243 2.1568 1.7894 1.4219 1.0544 0.6870 0.7355 1.1030 1.4704
Mt- -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008
Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008
My- -6.3383 -4.3908 -2.6737 -1.2884 -0.4005 -1.3043 -1.8388 -1.9733 -2.0675
My+ 7.0924 4.6499 2.5766 1.2534 1.9159 2.3725 2.4599 2.3039 2.5597
Mz- -1.7836 -1.3730 -0.9625 -0.5520 -0.1456 -0.1660 -0.4346 -0.7032 -0.9717
Mz+ 1.1768 0.9083 0.6397 0.3712 0.1067 0.2691 0.6796 1.0902 1.5007
56/58 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.3722 -0.3619 -0.3516 -0.3414 -0.3311 -0.3208 -0.3106 -0.3032 -0.3000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
25/106
N+ 1.1344 1.1376 1.1408 1.1440 1.1472 1.1504 1.1536 1.1597 1.1700
Ty- -0.0390 -0.0390 -0.0390 -0.0390 -0.0390 -0.0390 -0.0390 -0.0390 -0.0390
Ty+ 0.0513 0.0513 0.0513 0.0513 0.0513 0.0513 0.0513 0.0513 0.0513
Tz- -0.4542 -0.3476 -0.3224 -0.3378 -0.3695 -0.4556 -0.5608 -0.7582 -0.9556
Tz+ 0.7042 0.4766 0.2709 0.2258 0.2664 0.3712 0.4759 0.5807 0.6854
Mt- -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002
Mt+ 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001
My- -0.6017 -0.4605 -0.3331 -0.2478 -0.2173 -0.1241 -0.2481 -0.4980 -0.7952
My+ 0.4746 0.3187 0.2539 0.2014 0.1226 0.1761 0.3633 0.6395 0.9546
Mz- -0.0707 -0.0523 -0.0340 -0.0156 -0.0032 -0.0273 -0.0515 -0.0756 -0.0998
Mz+ 0.0935 0.0693 0.0451 0.0210 0.0027 0.0211 0.0394 0.0578 0.0761
57/58 0.000 m 1.094 m 2.187 m 3.281 m 4.375 m 5.469 m 6.562 m 7.656 m 8.750 m
Envolvente (Acero laminado)
N- -3.0178 -2.9287 -2.8397 -2.7507 -2.6617 -2.5727 -2.4836 -2.3946 -2.3056
N+ 1.9701 2.0229 2.0756 2.1284 2.1811 2.2339 2.2866 2.3394 2.3921
Ty- -0.3121 -0.3121 -0.3121 -0.3121 -0.3121 -0.3121 -0.3121 -0.3121 -0.3121
Ty+ 0.2052 0.2052 0.2052 0.2052 0.2052 0.2052 0.2052 0.2052 0.2052
Tz- -2.8410 -2.3570 -1.8730 -1.5843 -1.3053 -1.0264 -0.7475 -0.6147 -0.8595
Tz+ 3.0629 2.6150 2.1671 1.7193 1.2714 0.8235 0.9744 1.4584 1.9424
Mt- -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009
Mt+ 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009
My- -8.0120 -5.5227 -3.3262 -1.5847 -0.5761 -1.7119 -2.3774 -2.5335 -2.8759
My+ 8.9052 5.8099 3.1848 1.6504 2.7533 3.4679 3.6743 3.4131 3.7497
Mz- -1.5396 -1.1982 -0.8568 -0.5221 -0.1932 -0.1118 -0.3286 -0.5530 -0.7774
Mz+ 1.0178 0.7934 0.5690 0.3513 0.1394 0.1674 0.5088 0.8502 1.1916
58/60 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m
Envolvente (Acero laminado)
N- -0.5316 -0.5179 -0.5042 -0.4905 -0.4769 -0.4632 -0.4495 -0.4358 -0.4270
N+ 1.2271 1.2314 1.2356 1.2399 1.2442 1.2485 1.2527 1.2570 1.2662
Ty- -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158
Ty+ 0.0141 0.0141 0.0141 0.0141 0.0141 0.0141 0.0141 0.0141 0.0141
Tz- -0.6417 -0.4810 -0.3204 -0.1948 -0.2049 -0.3366 -0.5871 -0.8503 -1.1135
Tz+ 0.9924 0.7292 0.4659 0.2027 0.1377 0.2774 0.4170 0.5701 0.7324
Mt- -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001
Mt+ 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
My- -0.5215 -0.3777 -0.3424 -0.4460 -0.4939 -0.3699 -0.1493 -0.3867 -0.7785
My+ 0.6767 0.2420 0.2668 0.3146 0.3102 0.2510 0.2317 0.4827 0.9810
Mz- -0.0398 -0.0299 -0.0199 -0.0100 -0.0022 -0.0110 -0.0199 -0.0287 -0.0376
Mz+ 0.0331 0.0243 0.0155 0.0074 0.0022 0.0099 0.0198 0.0297 0.0397
59/60 0.000 m 1.156 m 2.312 m 3.469 m 4.625 m 5.781 m 6.937 m 8.094 m 9.250 m
Envolvente (Acero laminado)
N- -3.0106 -2.9165 -2.8224 -2.7283 -2.6342 -2.5401 -2.4460 -2.3519 -2.2578
N+ 1.8434 1.8991 1.9549 2.0107 2.0664 2.1222 2.1780 2.2337 2.2895
Ty- -0.2901 -0.2901 -0.2901 -0.2901 -0.2901 -0.2901 -0.2901 -0.2901 -0.2901
Ty+ 0.1989 0.1989 0.1989 0.1989 0.1989 0.1989 0.1989 0.1989 0.1989
Tz- -2.8682 -2.3566 -1.8476 -1.5528 -1.2579 -0.9631 -0.6682 -0.5944 -0.9867
Tz+ 3.1102 2.6367 2.1632 1.6897 1.2163 0.7428 0.9344 1.4461 1.9577
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
26/106
Mt- -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009
Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008
My- -8.2355 -5.5947 -3.2811 -1.4531 -0.7896 -1.9112 -2.5072 -2.5339 -2.6182
My+ 9.2153 5.9038 3.1179 1.6320 2.8617 3.5041 3.5787 3.2644 3.6793
Mz- -1.4604 -1.1250 -0.7896 -0.4570 -0.1361 -0.1593 -0.3893 -0.6193 -0.8494
Mz+ 0.9908 0.7607 0.5307 0.3035 0.0880 0.2166 0.5520 0.8874 1.2228
60/62 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.6572 -0.6469 -0.6366 -0.6264 -0.6161 -0.6058 -0.5956 -0.5853 -0.5804
N+ 1.3415 1.3447 1.3479 1.3511 1.3543 1.3575 1.3607 1.3639 1.3725
Ty- -0.0258 -0.0258 -0.0258 -0.0258 -0.0258 -0.0258 -0.0258 -0.0258 -0.0258
Ty+ 0.0277 0.0277 0.0277 0.0277 0.0277 0.0277 0.0277 0.0277 0.0277
Tz- -0.5063 -0.3858 -0.3102 -0.3162 -0.3316 -0.4034 -0.4894 -0.6549 -0.8891
Tz+ 0.7884 0.5910 0.3935 0.2106 0.1946 0.2851 0.3898 0.4946 0.5993
Mt- -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001
Mt+ 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002
My- -0.5809 -0.4499 -0.3120 -0.2268 -0.2469 -0.1979 -0.1626 -0.3532 -0.6099
My+ 0.4947 0.2724 0.2041 0.1840 0.1347 0.1511 0.3130 0.5459 0.8365
Mz- -0.0498 -0.0376 -0.0255 -0.0133 -0.0029 -0.0096 -0.0227 -0.0358 -0.0488
Mz+ 0.0557 0.0426 0.0295 0.0165 0.0034 0.0110 0.0231 0.0353 0.0474
61/62 0.000 m 1.203 m 2.406 m 3.609 m 4.813 m 6.016 m 7.219 m 8.422 m 9.625 m
Envolvente (Acero laminado)
N- -2.3978 -2.2998 -2.2019 -2.1040 -2.0061 -1.9082 -1.8102 -1.7123 -1.6144
N+ 1.2529 1.3110 1.3690 1.4270 1.4850 1.5431 1.6011 1.6591 1.7172
Ty- -0.2395 -0.2395 -0.2395 -0.2395 -0.2395 -0.2395 -0.2395 -0.2395 -0.2395
Ty+ 0.1712 0.1712 0.1712 0.1712 0.1712 0.1712 0.1712 0.1712 0.1712
Tz- -2.1870 -1.7729 -1.4857 -1.2222 -0.9588 -0.6953 -0.4318 -0.4920 -0.9143
Tz+ 2.6286 2.2063 1.7840 1.3617 0.9394 0.5171 0.6861 1.1084 1.5307
Mt- -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008
Mt+ 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006
My- -6.7515 -4.4948 -2.5425 -0.9918 -0.8722 -1.7383 -2.1166 -1.9665 -1.6978
My+ 7.7133 4.8150 2.4044 1.2978 2.1609 2.4957 2.3428 2.4262 2.4766
Mz- -1.2898 -1.0017 -0.7144 -0.4282 -0.1419 -0.1339 -0.3399 -0.5459 -0.7519
Mz+ 0.8960 0.6900 0.4848 0.2807 0.0765 0.1506 0.4387 0.7268 1.0149
62/64 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.7343 -0.7240 -0.7138 -0.7035 -0.6932 -0.6830 -0.6727 -0.6624 -0.6561
N+ 1.4781 1.4813 1.4845 1.4877 1.4909 1.4941 1.4973 1.5005 1.5077
Ty- -0.0408 -0.0408 -0.0408 -0.0408 -0.0408 -0.0408 -0.0408 -0.0408 -0.0408
Ty+ 0.0533 0.0533 0.0533 0.0533 0.0533 0.0533 0.0533 0.0533 0.0533
Tz- -0.4969 -0.3764 -0.2559 -0.2029 -0.3459 -0.5714 -0.8056 -1.0709 -1.3774
Tz+ 0.5997 0.3655 0.2316 0.1938 0.2254 0.3214 0.4262 0.5309 0.6357
Mt- -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003
Mt+ 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004
My- -0.3577 -0.3232 -0.3213 -0.3376 -0.3114 -0.1691 -0.2320 -0.4144 -0.6882
My+ 0.3598 0.2583 0.2203 0.1920 0.1746 0.2308 0.4912 0.8840 1.4268
Mz- -0.0751 -0.0559 -0.0366 -0.0174 -0.0031 -0.0282 -0.0533 -0.0784 -0.1035
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
27/106
Mz+ 0.0977 0.0726 0.0475 0.0224 0.0032 0.0214 0.0406 0.0599 0.0791
63/64 0.000 m 1.250 m 2.500 m 3.750 m 5.000 m 6.250 m 7.500 m 8.750 m 10.000 m
Envolvente (Acero laminado)
N- -1.7066 -1.5627 -1.4188 -1.2748 -1.1309 -0.9870 -0.8431 -0.6991 -0.5552
N+ 1.1155 1.2008 1.2861 1.3714 1.4567 1.5420 1.6272 1.7125 1.7978
Ty- -1.1680 -0.9487 -0.7293 -0.5099 -0.2905 -0.2312 -0.5593 -0.8874 -1.2156
Ty+ 1.4115 1.0833 0.7552 0.4376 0.2730 0.1361 0.1502 0.3696 0.5890
Tz- -1.7946 -1.5099 -1.2252 -0.9405 -0.6559 -0.3964 -0.7373 -1.2032 -1.6690
Tz+ 2.0806 1.6148 1.1489 0.6831 0.3803 0.2379 0.0956 0.2211 0.5058
Mt- -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007
Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008
My- -5.4290 -3.3708 -1.6543 -1.7189 -2.2930 -2.2617 -1.6714 -0.8333 -0.6895
My+ 3.4517 2.0188 1.0950 0.3618 0.6971 1.3318 1.6250 1.5480 1.4275
Mz- -2.8776 -1.5602 -0.5060 -0.9196 -1.2565 -1.1669 -0.8055 -0.7156 -0.4615
Mz+ 2.5195 1.3320 0.5596 0.2630 0.7688 0.9894 0.9467 0.6188 1.5434 6.- Tensiones
Barras TENSIÓN MÁXIMA
TENS. () APROV. (%) Pos. (m) N (t) Ty (t) Tz (t) Mt (t�m) My (t�m) Mz (t�m)
53/54 0.7940 79.40 0.000 -0.0334 -0.9615 -1.8608 -0.0003 -3.3896 -1.9659
54/56 0.7742 77.42 0.000 -0.1406 -0.0285 -0.4499 0.0000 -1.0539 -0.0565
55/56 0.6603 66.03 0.000 1.5810 -0.1090 2.5243 0.0000 7.0924 -0.5038
56/58 0.5811 58.11 3.769 -0.1767 0.0194 0.6854 -0.0002 -0.7952 -0.0374
57/58 0.8048 80.48 0.000 1.9701 -0.0591 3.0629 -0.0003 8.9052 -0.3538
58/60 0.7251 72.51 5.025 -0.0167 0.0115 0.6964 0.0000 -0.7785 -0.0288
59/60 0.8828 88.28 0.000 1.8434 -0.1049 3.1102 -0.0005 9.2153 -0.4836
60/62 0.4618 46.18 3.769 0.1388 0.0185 0.5993 0.0002 -0.6099 -0.0339
61/62 0.7629 76.29 0.000 1.2529 -0.0860 2.6286 -0.0008 7.7133 -0.4224
62/64 0.5722 57.22 3.769 1.5037 -0.0408 -1.2740 0.0003 1.4268 0.0786
63/64 0.9113 91.13 0.000 0.5252 1.4112 -1.7874 0.0008 -5.4034 2.5186
Resultados de cálculo en pórtico intermedio 1.- Barras: Descripción
Barras Material Perfil Peso Volumen Longitud Co.pand.xy Co.pand.xz Dist.arr.sup. Dist.arr.inf.
(kp) (m³) (m) (m) (m)
13/14 Acero (S275) HE 260 A (HEA) 545.10 0.069 8.00 0.70 1.33 8.00 8.00
14/15 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77
15/16 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77
16/17 Acero (S275) IPE 450 (IPE) 389.72 0.050 5.02 0.05 0.73 1.00 5.02
17/18 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77
18/20 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77
19/20 Acero (S275) HE 300 A (HEA) 883.12 0.112 10.00 0.70 1.28 10.00 10.00
2.- Cargas (Barras)
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
28/106
Barras Hipót. Tipo Cargas Dirección
P1 P2 L1 (m) L2 (m) X Y Z
13/14 1 (PP 1) Uniforme 0.068 t/m - - - 0.000 0.000 -1.000
13/14 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000
13/14 3 (V 1) Uniforme 0.304 t/m - - - 0.000 1.000 0.000
13/14 4 (V 2) Uniforme 0.304 t/m - - - 0.000 1.000 0.000
13/14 5 (V 3) Uniforme 0.149 t/m - - - 0.000 -1.000 0.000
13/14 5 (V 3) Uniforme 0.232 t/m - - - 0.000 -1.000 0.000
13/14 6 (V 4) Uniforme 0.152 t/m - - - 0.000 -1.000 0.000
13/14 7 (V 5) Uniforme 0.207 t/m - - - 0.000 -1.000 0.000
14/15 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000
14/15 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000
14/15 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000
14/15 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 2.010 3.769 0.000 -0.100 0.995
14/15 3 (V 1) Trapez. 0.583 t/m 0.583 t/m 0.000 2.010 0.000 -0.100 0.995
14/15 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 2.010 3.769 0.000 0.100 -0.995
14/15 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 2.010 0.000 0.100 -0.995
14/15 5 (V 3) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995
14/15 6 (V 4) Uniforme 0.334 t/m - - - 0.000 -0.100 0.995
14/15 7 (V 5) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995
14/15 8 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
14/15 9 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
15/16 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000
15/16 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000
15/16 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000
15/16 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 0.000 3.769 0.000 -0.100 0.995
15/16 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 3.769 0.000 0.100 -0.995
15/16 5 (V 3) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995
15/16 6 (V 4) Uniforme 0.334 t/m - - - 0.000 -0.100 0.995
15/16 7 (V 5) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995
15/16 8 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
15/16 9 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
16/17 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000
16/17 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000
16/17 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000
16/17 3 (V 1) Uniforme 0.240 t/m - - - 0.000 -0.100 0.995
16/17 4 (V 2) Uniforme 0.006 t/m - - - 0.000 0.100 -0.995
16/17 5 (V 3) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995
16/17 6 (V 4) Uniforme 0.334 t/m - - - 0.000 -0.100 0.995
16/17 7 (V 5) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995
16/17 8 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
16/17 9 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
17/18 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000
17/18 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000
17/18 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000
17/18 3 (V 1) Uniforme 0.240 t/m - - - 0.000 -0.100 0.995
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
29/106
17/18 4 (V 2) Uniforme 0.006 t/m - - - 0.000 0.100 -0.995
17/18 5 (V 3) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995
17/18 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995
17/18 7 (V 5) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995
17/18 8 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
17/18 9 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
18/20 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000
18/20 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000
18/20 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000
18/20 3 (V 1) Uniforme 0.240 t/m - - - 0.000 -0.100 0.995
18/20 4 (V 2) Uniforme 0.006 t/m - - - 0.000 0.100 -0.995
18/20 5 (V 3) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995
18/20 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 1.759 0.000 -0.100 0.995
18/20 6 (V 4) Trapez. 0.748 t/m 0.748 t/m 1.759 3.769 0.000 -0.100 0.995
18/20 7 (V 5) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995
18/20 8 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
18/20 9 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
19/20 1 (PP 1) Uniforme 0.088 t/m - - - 0.000 0.000 -1.000
19/20 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000
19/20 3 (V 1) Uniforme 0.152 t/m - - - 0.000 1.000 0.000
19/20 4 (V 2) Uniforme 0.152 t/m - - - 0.000 1.000 0.000
19/20 5 (V 3) Uniforme 0.149 t/m - - - 0.000 1.000 0.000
19/20 5 (V 3) Uniforme 0.232 t/m - - - 0.000 1.000 0.000
19/20 6 (V 4) Uniforme 0.304 t/m - - - 0.000 -1.000 0.000
19/20 7 (V 5) Uniforme 0.207 t/m - - - 0.000 1.000 0.000 3.- Desplazamientos
Nudos Descripción DESPLAZAMIENTOS (EJES GENERALES)
DX (m) DY (m) DZ (m) GX (rad) GY (rad) GZ (rad)
13 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
14 Envolvente (Desplazam.) -0.0176 -0.0364 -0.0002 -0.0069 -0.0007 -0.0027
0.0176 0.0249 0.0000 0.0027 0.0007 0.0028
15 Envolvente (Desplazam.) -0.0305 -0.0371 -0.0268 -0.0064 -0.0017 -0.0030
0.0306 0.0276 0.0065 0.0009 0.0048 0.0034
16 Envolvente (Desplazam.) -0.0411 -0.0372 -0.0445 -0.0028 -0.0023 -0.0018
0.0411 0.0293 0.0077 -0.0001 0.0082 0.0024
17 Envolvente (Desplazam.) -0.0451 -0.0368 -0.0416 -0.0010 -0.0017 -0.0004
0.0452 0.0290 0.0041 0.0036 0.0080 0.0010
18 Envolvente (Desplazam.) -0.0381 -0.0365 -0.0223 -0.0007 -0.0008 -0.0024
0.0382 0.0270 0.0005 0.0062 0.0044 0.0029
19 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
20 Envolvente (Desplazam.) -0.0256 -0.0365 -0.0002 -0.0003 -0.0010 -0.0028
0.0256 0.0248 0.0000 0.0049 0.0011 0.0029
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
30/106
4.- Reacciones
Nudos Descripción REACCIONES (EJES GENERALES)
RX (t) RY (t) RZ (t) MX (t�m) MY (t�m) MZ (t�m)
13 Envolvente (Cim.equil.) -0.4248 -3.3740 -0.4557 -11.8280 -1.8079 -0.0024
0.4292 3.5315 6.5812 8.1702 1.8185 0.0023
13 Envolvente (Cim.tens.terr.) -0.2655 -1.8932 0.7887 -8.0101 -1.1300 -0.0015
0.2684 2.4432 4.6167 4.5425 1.1370 0.0015
19 Envolvente (Cim.equil.) -0.5176 -4.0794 -1.5820 -17.3800 -2.8097 -0.0032
0.5258 5.1257 7.7765 14.4816 2.8360 0.0030
19 Envolvente (Cim.tens.terr.) -0.3235 -2.7852 0.2413 -10.1561 -1.7561 -0.0020
0.3287 2.9885 5.6340 9.8249 1.7730 0.0019 5.- Esfuerzos
Barras Esf. ESFUERZOS (EJES LOCALES) (t)(t�m)
0 L 1/8 L 1/4 L 3/8 L 1/2 L 5/8 L 3/4 L 7/8 L 1 L
13/14 0.000 m 1.000 m 2.000 m 3.000 m 4.000 m 5.000 m 6.000 m 7.000 m 8.000 m
Envolvente (Acero laminado)
N- -6.0089 -5.8494 -5.6899 -5.5304 -5.3709 -5.2114 -5.0520 -4.8925 -4.7330
N+ 0.8208 0.9153 1.0098 1.1043 1.1988 1.2934 1.3879 1.4824 1.5769
Ty- -0.4024 -0.4024 -0.4024 -0.4024 -0.4024 -0.4024 -0.4024 -0.4024 -0.4024
Ty+ 0.3982 0.3982 0.3982 0.3982 0.3982 0.3982 0.3982 0.3982 0.3982
Tz- -3.2785 -2.9899 -2.7622 -2.5345 -2.3067 -2.0790 -1.8512 -1.6450 -1.6444
Tz+ 3.2421 2.7866 2.3311 1.8756 1.4201 0.9646 0.9365 1.5080 2.0794
Mt- -0.0022 -0.0022 -0.0022 -0.0022 -0.0022 -0.0022 -0.0022 -0.0022 -0.0022
Mt+ 0.0023 0.0023 0.0023 0.0023 0.0023 0.0023 0.0023 0.0023 0.0023
My- -11.0042 -7.9049 -5.0243 -2.6819 -1.4581 -2.6413 -3.3873 -3.6595 -3.4945
My+ 7.8663 5.0008 2.8670 1.6466 2.6308 3.5949 4.7994 6.5022 8.0817
Mz- -1.7050 -1.3026 -0.9002 -0.4980 -0.0965 -0.2964 -0.6947 -1.0929 -1.4912
Mz+ 1.6948 1.2966 0.8983 0.5003 0.1029 0.3070 0.7094 1.1118 1.5142
14/15 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -2.0577 -2.0307 -2.0037 -1.9767 -1.9497 -1.9227 -1.8957 -1.8686 -1.8416
N+ 2.1270 2.1351 2.1433 2.1514 2.1595 2.1677 2.1758 2.1839 2.1921
Ty- -0.2417 -0.2417 -0.2417 -0.2417 -0.2417 -0.2417 -0.2417 -0.2417 -0.2417
Ty+ 0.2105 0.2105 0.2105 0.2105 0.2105 0.2105 0.2105 0.2105 0.2105
Tz- -4.2148 -3.9447 -3.6745 -3.4044 -3.1343 -2.8642 -2.5941 -2.3240 -2.0538
Tz+ 2.0645 1.7341 1.4036 1.1251 1.0556 0.9865 0.9174 0.8483 0.7791
Mt- -0.0057 -0.0057 -0.0057 -0.0057 -0.0057 -0.0057 -0.0057 -0.0057 -0.0057
Mt+ 0.0093 0.0093 0.0093 0.0093 0.0093 0.0093 0.0093 0.0093 0.0093
My- -8.0823 -6.9079 -6.2791 -5.6924 -5.1049 -4.9067 -5.0277 -5.0728 -5.0478
My+ 3.4944 2.6028 1.8606 1.8382 2.2663 3.0427 4.1003 5.0410 5.8738
Mz- -0.4856 -0.3718 -0.2579 -0.1440 -0.0302 -0.0787 -0.1775 -0.2767 -0.3759
Mz+ 0.4174 0.3182 0.2191 0.1199 0.0208 0.0839 0.1975 0.3114 0.4253
15/16 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -1.8762 -1.8492 -1.8222 -1.7951 -1.7681 -1.7411 -1.7141 -1.6871 -1.6601
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
31/106
N+ 2.1985 2.2067 2.2148 2.2230 2.2311 2.2392 2.2474 2.2555 2.2636
Ty- -0.1625 -0.1625 -0.1625 -0.1625 -0.1625 -0.1625 -0.1625 -0.1625 -0.1625
Ty+ 0.1420 0.1420 0.1420 0.1420 0.1420 0.1420 0.1420 0.1420 0.1420
Tz- -2.5497 -2.2795 -2.0094 -1.7393 -1.4692 -1.1991 -0.9290 -0.7955 -0.7880
Tz+ 0.7255 0.6554 0.5863 0.5172 0.4481 0.3790 0.3098 0.2407 0.1716
Mt- -0.0031 -0.0031 -0.0031 -0.0031 -0.0031 -0.0031 -0.0031 -0.0031 -0.0031
Mt+ 0.0066 0.0066 0.0066 0.0066 0.0066 0.0066 0.0066 0.0066 0.0066
My- -5.0481 -5.3178 -5.5175 -5.6414 -5.6952 -5.6731 -5.5811 -5.4132 -5.1753
My+ 5.8734 6.7840 7.5867 8.3700 9.0760 9.6484 10.0975 10.4130 10.6052
Mz- -0.1411 -0.0645 -0.0291 -0.0956 -0.1622 -0.2289 -0.2958 -0.3627 -0.4296
Mz+ 0.1055 0.0508 0.0318 0.0891 0.1653 0.2417 0.3183 0.3949 0.4714
16/17 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m
Envolvente (Acero laminado)
N- -1.7408 -1.7048 -1.6688 -1.6328 -1.5968 -1.5608 -1.5247 -1.4887 -1.4527
N+ 2.2932 2.3041 2.3149 2.3258 2.3366 2.3475 2.3583 2.3692 2.3800
Ty- -0.0479 -0.0479 -0.0479 -0.0479 -0.0479 -0.0479 -0.0479 -0.0479 -0.0479
Ty+ 0.0340 0.0340 0.0340 0.0340 0.0340 0.0340 0.0340 0.0340 0.0340
Tz- -1.3722 -1.0120 -0.6519 -0.4326 -0.4717 -0.6781 -0.8845 -1.0910 -1.2974
Tz+ 0.5514 0.4341 0.3168 0.2031 0.3125 0.6306 0.9488 1.3103 1.6738
Mt- -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009
Mt+ 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009
My- -5.1760 -5.3309 -5.3614 -5.2570 -5.0282 -4.6645 -4.1763 -3.5533 -2.8058
My+ 10.6053 11.2617 11.6989 11.8987 11.8793 11.6225 11.1465 10.4331 9.5004
Mz- -0.1718 -0.1927 -0.2136 -0.2345 -0.2554 -0.2764 -0.2977 -0.3190 -0.3403
Mz+ 0.1368 0.1665 0.1961 0.2258 0.2554 0.2852 0.3153 0.3454 0.3754
17/18 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -1.5205 -1.4934 -1.4664 -1.4394 -1.4124 -1.3854 -1.3584 -1.3314 -1.3044
N+ 2.4444 2.4525 2.4606 2.4688 2.4769 2.4850 2.4932 2.5013 2.5094
Ty- -0.1334 -0.1334 -0.1334 -0.1334 -0.1334 -0.1334 -0.1334 -0.1334 -0.1334
Ty+ 0.1136 0.1136 0.1136 0.1136 0.1136 0.1136 0.1136 0.1136 0.1136
Tz- -0.5037 -0.6586 -0.8134 -0.9682 -1.1230 -1.2778 -1.4326 -1.5875 -1.7423
Tz+ 0.9699 1.2086 1.4472 1.6858 1.9319 2.2045 2.4771 2.7497 3.0223
Mt- -0.0069 -0.0069 -0.0069 -0.0069 -0.0069 -0.0069 -0.0069 -0.0069 -0.0069
Mt+ 0.0039 0.0039 0.0039 0.0039 0.0039 0.0039 0.0039 0.0039 0.0039
My- -2.8064 -2.5311 -2.1859 -2.0495 -2.0106 -1.9287 -1.8069 -1.6421 -1.4374
My+ 9.5009 9.0505 8.5835 7.9980 7.2904 6.4504 5.4883 4.3938 3.3999
Mz- -0.5346 -0.4717 -0.4089 -0.3460 -0.2832 -0.2205 -0.1582 -0.0959 -0.0692
Mz+ 0.4950 0.4415 0.3880 0.3345 0.2810 0.2276 0.1747 0.1217 0.0687
18/20 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -1.3151 -1.2881 -1.2611 -1.2341 -1.2071 -1.1801 -1.1530 -1.1260 -1.0990
N+ 2.5907 2.5988 2.6070 2.6151 2.6232 2.6314 2.6395 2.6476 2.6558
Ty- -0.3173 -0.3173 -0.3173 -0.3173 -0.3173 -0.3173 -0.3173 -0.3173 -0.3173
Ty+ 0.2896 0.2896 0.2896 0.2896 0.2896 0.2896 0.2896 0.2896 0.2896
Tz- -1.1942 -1.3491 -1.5039 -1.6587 -1.8914 -2.3388 -2.7863 -3.2337 -3.6811
Tz+ 2.8327 3.0713 3.3177 3.5903 3.8629 4.1355 4.4082 4.6808 4.9534
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
32/106
Mt- -0.0083 -0.0083 -0.0083 -0.0083 -0.0083 -0.0083 -0.0083 -0.0083 -0.0083
Mt+ 0.0040 0.0040 0.0040 0.0040 0.0040 0.0040 0.0040 0.0040 0.0040
My- -1.4372 -1.4597 -2.1110 -3.3031 -5.0287 -6.8713 -8.8217 -10.8890 -13.0643
My+ 3.4001 3.1471 3.1220 3.4428 4.2641 5.2647 6.4677 7.8899 9.5144
Mz- -0.6112 -0.4618 -0.3123 -0.1628 -0.0165 -0.1143 -0.2506 -0.3870 -0.5234
Mz+ 0.5679 0.4315 0.2951 0.1587 0.0223 0.1364 0.2858 0.4352 0.5847
19/20 0.000 m 1.250 m 2.500 m 3.750 m 5.000 m 6.250 m 7.500 m 8.750 m 10.000 m
Envolvente (Acero laminado)
N- -7.1060 -6.8726 -6.6392 -6.4058 -6.1724 -5.9390 -5.7056 -5.4722 -5.2387
N+ 1.9341 2.0725 2.2108 2.3491 2.4874 2.6257 2.7640 2.9023 3.0406
Ty- -0.4929 -0.4929 -0.4929 -0.4929 -0.4929 -0.4929 -0.4929 -0.4929 -0.4929
Ty+ 0.4852 0.4852 0.4852 0.4852 0.4852 0.4852 0.4852 0.4852 0.4852
Tz- -4.8842 -4.3148 -3.7455 -3.1761 -2.6067 -2.0373 -1.4680 -2.1064 -2.8207
Tz+ 3.7922 3.5075 3.2228 2.9381 2.6534 2.3687 2.0840 1.7994 1.5786
Mt- -0.0029 -0.0029 -0.0029 -0.0029 -0.0029 -0.0029 -0.0029 -0.0029 -0.0029
Mt+ 0.0030 0.0030 0.0030 0.0030 0.0030 0.0030 0.0030 0.0030 0.0030
My- -16.5527 -10.8176 -5.7657 -2.6896 -4.0692 -5.7751 -8.5652 -10.9852 -13.0636
My+ 13.4705 8.9154 4.7018 1.2239 2.1745 5.0628 7.2679 8.7327 9.5143
Mz- -2.6589 -2.0428 -1.4266 -0.8107 -0.1955 -0.3984 -1.0049 -1.6114 -2.2179
Mz+ 2.6340 2.0275 1.4210 0.8149 0.2094 0.4220 1.0382 1.6543 2.2705 6.- Tensiones
Barras TENSIÓN MÁXIMA
TENS. () APROV. (%) Pos. (m) N (t) Ty (t) Tz (t) Mt (t�m) My (t�m) Mz (t�m)
13/14 0.7336 73.36 0.000 -3.1059 0.0171 -3.2177 -0.0002 -11.0042 0.0433
14/15 0.2701 27.01 0.000 -1.8066 0.0347 -2.7432 0.0037 -8.0823 0.0752
15/16 0.2444 24.44 3.769 -1.6601 -0.0169 -0.2663 0.0064 10.6052 0.0349
16/17 0.2692 26.92 2.010 -1.6256 -0.0119 -0.0709 -0.0007 11.9167 -0.0059
17/18 0.2196 21.96 0.000 -1.5205 -0.0171 0.8414 -0.0069 9.5009 -0.0348
18/20 0.4278 42.78 3.769 -1.0625 -0.0462 4.7416 -0.0064 -13.0643 0.1007
19/20 0.7386 73.86 0.000 1.9341 0.0377 -4.8842 -0.0002 -16.5527 0.1218
2.1.2 Cimentación
La cimentación se realiza mediante zapatas centradas para todos los
pilares, arriostradas mediante vigas de atado de hormigón armado.
Tanto las zapatas como las vigas de atado se realizarán con hormigón
armado HA-35/B/20/IV-Qc sobre cama de hormigón de limpieza HM-10 de 10
cm de espesor, y armadura de redondos de acero B-400-S.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
33/106
• Acciones adoptadas en el cálculo
Para los elementos de cimentación de hormigón armado, se han
considerado las siguientes acciones:
Densidad del hormigón armado 2.50 tn/m² (2.30 t/m3 para hormigones en masa y poco armados)
Cargas y sobrecargas: Las consideradas en el CTE DB SE-A
Acciones de la estructura sobre la cimentación.
• Métodos de cálculo e hipótesis de carga
Para el cálculo de los elementos de hormigón se han considerado los
siguientes coeficientes de seguridad, correspondientes a la EHE.
COEFICIENTE DE PONDERACIÓN Y SEGURIDAD
Coeficiente de minoración de resistencia del hormigón γc = 1,50
Coeficiente de minoración de resistencia del acero γs = 1,15
Coeficiente de mayoración de las acciones γf = 1,60
• Resultados obtenidos en el cálculo de la cimentación
Descripción
Referencias Materiales Geometría Armado
Nudo 1 Nudo 15 Nudo 83 Nudo 97
Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa
Zapata cuadrada Ancho: 230.0 cm Canto: 55.0 cm
Sup X: 11Ø12c/20 Sup Y: 11Ø12c/20 Inf X: 11Ø12c/20 Inf Y: 11Ø12c/20
Nudo 28 Nudo 41 Nudo 54 Nudo 67 Nudo 80
Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa
Zapata rectangular centrada Ancho zapata X: 370.0 cm Ancho zapata Y: 190.0 cm Canto: 90.0 cm
Sup X: 29Ø12c/12.5 Sup Y: 15Ø12c/12.5 Inf X: 29Ø12c/12.5 Inf Y: 15Ø12c/12.5
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
34/106
Nudo 3 Nudo 6 Nudo 9 Nudo 12 Nudo 85 Nudo 88 Nudo 91 Nudo 94
Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa
Zapata rectangular centrada Ancho zapata X: 250.0 cm Ancho zapata Y: 120.0 cm Canto: 60.0 cm
Sup X: 14Ø12c/18 Sup Y: 6Ø12c/18 Inf X: 14Ø12c/18 Inf Y: 6Ø12c/18
Nudo 18 Nudo 31 Nudo 44 Nudo 57 Nudo 70
Hormigón: HA-35, Yc=1.5 Acero: B 500 S, Ys=1.15 Tensión admisible en situaciones persistentes: 0.250 MPa Tensión admisible en situaciones accidentales: 0.300 MPa
Zapata rectangular centrada Ancho zapata X: 330.0 cm Ancho zapata Y: 170.0 cm Canto: 80.0 cm
Sup X: 13Ø16c/25 Sup Y: 7Ø16c/25 Inf X: 13Ø16c/25 Inf Y: 7Ø16c/25
Descripción
A continuación mostramos las comprobaciones para una zapata de cada
tipo:
• Zapata NUDO 1:
Referencia: 1
Dimensiones: 230 x 230 x 55
Armados: Xi:Ø12c/20 Yi:Ø12c/20 Xs:Ø12c/20 Ys:Ø12c/20
Comprobación Valores Estado
Tensiones sobre el terreno:
Criterio de CYPE Ingenieros
-Tensión media en situaciones persistentes:
Máximo: 2 kp/cm² Calculado: 0.176 kp/cm²
Cumple -Tensión máxima en situaciones persistentes sin viento:
Máximo: 2.5 kp/cm² Calculado: 0.158 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes con viento:
Máximo: 2.5 kp/cm² Calculado: 0.423 kp/cm²
Cumple
Vuelco de la zapata:
Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.
-En dirección X:
Reserva seguridad: 272.3 %
Cumple -En dirección Y:
Reserva seguridad: 29.6 %
Cumple
Flexión en la zapata:
-En dirección X:
Momento: 1.15 t�m
Cumple
-En dirección Y:
Momento: 3.79 t�m
Cumple
Cortante en la zapata:
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
35/106
-En dirección X:
Cortante: 1.22 t
Cumple
-En dirección Y:
Cortante: 4.44 t
Cumple
Compresión oblicua en la zapata:
-Situaciones persistentes:
Criterio de CYPE Ingenieros
Máximo: 509.68 t/m² Calculado: 6.34 t/m²
Cumple
Canto mínimo:
Artículo 59.8.1 (norma EHE-98)
Mínimo: 25 cm Calculado: 55 cm
Cumple
Espacio para anclar arranques en cimentación:
-1:
Mínimo: 0 cm Calculado: 48 cm
Cumple
Cuantía geométrica mínima:
Criterio de CYPE Ingenieros
Mínimo: 0.002
-En dirección X:
Calculado: 0.0021
Cumple
-En dirección Y:
Calculado: 0.0021
Cumple
Cuantía mínima necesaria por flexión:
Artículo 42.3.2 (norma EHE-98)
Calculado: 0.0011
-Armado inferior dirección X:
Mínimo: 0.0001
Cumple
-Armado inferior dirección Y:
Mínimo: 0.0003
Cumple
-Armado superior dirección X:
Mínimo: 0.0001
Cumple
-Armado superior dirección Y:
Mínimo: 0.0003
Cumple
Diámetro mínimo de las barras:
Recomendación del Artículo 59.8.2 (norma EHE-98)
Mínimo: 12 mm
-Parrilla inferior:
Calculado: 12 mm
Cumple
-Parrilla superior:
Calculado: 12 mm
Cumple
Separación máxima entre barras:
Artículo 59.8.2 (norma EHE-98)
Máximo: 30 cm
-Armado inferior dirección X:
Calculado: 20 cm
Cumple
-Armado inferior dirección Y:
Calculado: 20 cm
Cumple
-Armado superior dirección X:
Calculado: 20 cm
Cumple
-Armado superior dirección Y:
Calculado: 20 cm
Cumple
Separación mínima entre barras:
Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 10 cm
-Armado inferior dirección X:
Calculado: 20 cm
Cumple
-Armado inferior dirección Y:
Calculado: 20 cm
Cumple
-Armado superior dirección X:
Calculado: 20 cm
Cumple -Armado superior dirección Y:
Calculado: 20 cm
Cumple
Longitud de anclaje:
Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 15 cm
-Armado inf. dirección X hacia der:
Calculado: 59 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 59 cm
Cumple
-Armado inf. dirección Y hacia arriba:
Calculado: 59 cm
Cumple
-Armado inf. dirección Y hacia abajo:
Calculado: 59 cm
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
36/106
-Armado sup. dirección X hacia der:
Calculado: 59 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 59 cm
Cumple
-Armado sup. dirección Y hacia arriba:
Calculado: 59 cm
Cumple
-Armado sup. dirección Y hacia abajo:
Calculado: 59 cm
Cumple
Se cumplen todas las comprobaciones
Información adicional:
- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))
- Relación rotura pésima (En dirección X): 0.07
- Relación rotura pésima (En dirección Y): 0.20
- Cortante de agotamiento (En dirección X): 31.64 t
- Cortante de agotamiento (En dirección Y): 31.64 t
• Zapata NUDO 9:
Referencia: 9
Dimensiones: 120 x 250 x 60
Armados: Xi:Ø12c/18 Yi:Ø12c/18 Xs:Ø12c/18 Ys:Ø12c/18
Comprobación Valores Estado
Tensiones sobre el terreno:
Criterio de CYPE Ingenieros
-Tensión media en situaciones persistentes:
Máximo: 2 kp/cm² Calculado: 0.214 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes sin viento:
Máximo: 2.5 kp/cm² Calculado: 0.214 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes con viento:
Máximo: 2.5 kp/cm² Calculado: 0.391 kp/cm²
Cumple
Vuelco de la zapata:
Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.
-En dirección X:
Reserva seguridad: 1690.9 %
Cumple
-En dirección Y:
Reserva seguridad: 4.3 %
Cumple
Flexión en la zapata:
-En dirección X:
Momento: 0.39 t�m
Cumple
-En dirección Y:
Momento: 2.19 t�m
Cumple
Cortante en la zapata:
-En dirección X:
Cortante: 0.06 t
Cumple
-En dirección Y:
Cortante: 2.38 t
Cumple
Compresión oblicua en la zapata:
-Situaciones persistentes:
Criterio de CYPE Ingenieros
Máximo: 509.68 t/m² Calculado: 11.12 t/m²
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
37/106
Canto mínimo:
Artículo 59.8.1 (norma EHE-98)
Mínimo: 25 cm Calculado: 60 cm
Cumple
Espacio para anclar arranques en cimentación:
-9:
Mínimo: 0 cm Calculado: 53 cm
Cumple
Cuantía geométrica mínima:
Criterio de CYPE Ingenieros
Mínimo: 0.002
-En dirección X:
Calculado: 0.0021
Cumple
-En dirección Y:
Calculado: 0.0021
Cumple
Cuantía mínima necesaria por flexión:
Artículo 42.3.2 (norma EHE-98)
Calculado: 0.0011
-Armado inferior dirección X:
Mínimo: 0.0001
Cumple
-Armado inferior dirección Y:
Mínimo: 0.0003
Cumple
-Armado superior dirección X:
Mínimo: 0.0001
Cumple
-Armado superior dirección Y:
Mínimo: 0.0003
Cumple
Diámetro mínimo de las barras:
Recomendación del Artículo 59.8.2 (norma EHE-
Mínimo: 12 mm
-Parrilla inferior:
Calculado: 12 mm
Cumple
-Parrilla superior:
Calculado: 12 mm
Cumple
Separación máxima entre barras:
Artículo 59.8.2 (norma EHE-98)
Máximo: 30 cm
-Armado inferior dirección X:
Calculado: 18 cm
Cumple
-Armado inferior dirección Y:
Calculado: 18 cm
Cumple
-Armado superior dirección X:
Calculado: 18 cm
Cumple
-Armado superior dirección Y:
Calculado: 18 cm
Cumple
Separación mínima entre barras:
Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 10 cm
-Armado inferior dirección X:
Calculado: 18 cm
Cumple
-Armado inferior dirección Y:
Calculado: 18 cm
Cumple
-Armado superior dirección X:
Calculado: 18 cm
Cumple
-Armado superior dirección Y:
Calculado: 18 cm
Cumple
Longitud de anclaje:
Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 15 cm
-Armado inf. dirección X hacia der:
Calculado: 15 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 15 cm
Cumple
-Armado inf. dirección Y hacia arriba:
Calculado: 65 cm
Cumple
-Armado inf. dirección Y hacia abajo:
Calculado: 65 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 15 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 15 cm
Cumple
-Armado sup. dirección Y hacia arriba:
Calculado: 65 cm
Cumple
-Armado sup. dirección Y hacia abajo:
Calculado: 65 cm
Cumple
Longitud mínima de las patillas: Mínimo: 12 cm
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
38/106
-Armado inf. dirección X hacia der:
Calculado: 15 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 15 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 15 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 15 cm
Cumple
Se cumplen todas las comprobaciones
Información adicional:
- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))
- Relación rotura pésima (En dirección X): 0.02
- Relación rotura pésima (En dirección Y): 0.19
- Cortante de agotamiento (En dirección X): 37.35 t
- Cortante de agotamiento (En dirección Y): 17.65 t
• Zapata NUDO 18:
Referencia: 18
Dimensiones: 170 x 330 x 80
Armados: Xi:Ø16c/25 Yi:Ø16c/25 Xs:Ø16c/25 Ys:Ø16c/25
Comprobación Valores Estado
Tensiones sobre el terreno:
Criterio de CYPE Ingenieros
-Tensión media en situaciones persistentes:
Máximo: 2 kp/cm² Calculado: 0.352 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes sin viento:
Máximo: 2.5 kp/cm² Calculado: 0.431 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes con viento:
Máximo: 2.5 kp/cm² Calculado: 0.524 kp/cm²
Cumple
Vuelco de la zapata:
-En dirección X (1)
No procede
-En dirección Y:
Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.
Reserva seguridad: 16.7 %
Cumple (1)Sin momento de vuelco
Flexión en la zapata:
-En dirección X:
Momento: 2.38 t�m
Cumple
-En dirección Y:
Momento: 7.59 t�m
Cumple
Cortante en la zapata:
-En dirección X:
Cortante: 0.28 t
Cumple
-En dirección Y:
Cortante: 5.26 t
Cumple
Compresión oblicua en la zapata:
-Situaciones persistentes:
Criterio de CYPE Ingenieros
Máximo: 509.68 t/m² Calculado: 31.46 t/m²
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
39/106
Canto mínimo:
Artículo 59.8.1 (norma EHE-98)
Mínimo: 25 cm Calculado: 80 cm
Cumple
Espacio para anclar arranques en cimentación:
-18:
Mínimo: 0 cm Calculado: 72 cm
Cumple
Cuantía geométrica mínima:
Criterio de CYPE Ingenieros
Mínimo: 0.002
-En dirección X:
Calculado: 0.0021
Cumple
-En dirección Y:
Calculado: 0.0021
Cumple
Cuantía mínima necesaria por flexión:
Artículo 42.3.2 (norma EHE-98)
Calculado: 0.0011
-Armado inferior dirección X:
Mínimo: 0.0001
Cumple
-Armado inferior dirección Y:
Mínimo: 0.0004
Cumple
-Armado superior dirección X:
Mínimo: 0.0001
Cumple
-Armado superior dirección Y:
Mínimo: 0.0003
Cumple
Diámetro mínimo de las barras:
Recomendación del Artículo 59.8.2 (norma EHE-
Mínimo: 12 mm
-Parrilla inferior:
Calculado: 16 mm
Cumple
-Parrilla superior:
Calculado: 16 mm
Cumple
Separación máxima entre barras:
Artículo 59.8.2 (norma EHE-98)
Máximo: 30 cm
-Armado inferior dirección X:
Calculado: 25 cm
Cumple
-Armado inferior dirección Y:
Calculado: 25 cm
Cumple
-Armado superior dirección X:
Calculado: 25 cm
Cumple
-Armado superior dirección Y:
Calculado: 25 cm
Cumple
Separación mínima entre barras:
Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 10 cm
-Armado inferior dirección X:
Calculado: 25 cm
Cumple
-Armado inferior dirección Y:
Calculado: 25 cm
Cumple
-Armado superior dirección X:
Calculado: 25 cm
Cumple
-Armado superior dirección Y:
Calculado: 25 cm
Cumple
Longitud de anclaje:
Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 16 cm
-Armado inf. dirección X hacia der:
Calculado: 16 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 16 cm
Cumple
-Armado inf. dirección Y hacia arriba:
Calculado: 89 cm
Cumple
-Armado inf. dirección Y hacia abajo:
Calculado: 89 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 16 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 16 cm
Cumple
-Armado sup. dirección Y hacia arriba:
Calculado: 89 cm
Cumple
-Armado sup. dirección Y hacia abajo:
Calculado: 89 cm
Cumple
Longitud mínima de las patillas: Mínimo: 16 cm
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
40/106
-Armado inf. dirección X hacia der:
Calculado: 16 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 16 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 16 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 16 cm
Cumple
Se cumplen todas las comprobaciones
Información adicional:
- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))
- Relación rotura pésima (En dirección X): 0.04
- Relación rotura pésima (En dirección Y): 0.26
- Cortante de agotamiento (En dirección X): 62.46 t
- Cortante de agotamiento (En dirección Y): 31.86 t
• Zapata NUDO 41:
Referencia: 41
Dimensiones: 190 x 370 x 90
Armados: Xi:Ø12c/12.5 Yi:Ø12c/12.5 Xs:Ø12c/12.5 Ys:Ø12c/12.5
Comprobación Valores Estado
Tensiones sobre el terreno:
Criterio de CYPE Ingenieros
-Tensión media en situaciones persistentes:
Máximo: 2 kp/cm² Calculado: 0.35 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes sin viento:
Máximo: 2.5 kp/cm² Calculado: 0.414 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes con viento:
Máximo: 2.5 kp/cm² Calculado: 0.598 kp/cm²
Cumple
Vuelco de la zapata:
-En dirección X (1)
No procede
-En dirección Y:
Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.
Reserva seguridad: 12.7 %
Cumple (1)Sin momento de vuelco
Flexión en la zapata:
-En dirección X:
Momento: 2.72 t�m
Cumple
-En dirección Y:
Momento: 12.80 t�m
Cumple
Cortante en la zapata:
-En dirección X:
Cortante: 0.09 t
Cumple
-En dirección Y:
Cortante: 9.29 t
Cumple
Compresión oblicua en la zapata:
-Situaciones persistentes:
Criterio de CYPE Ingenieros
Máximo: 509.68 t/m² Calculado: 22.87 t/m²
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
41/106
Canto mínimo:
Artículo 59.8.1 (norma EHE-98)
Mínimo: 25 cm Calculado: 90 cm
Cumple
Espacio para anclar arranques en cimentación:
-41:
Mínimo: 0 cm Calculado: 83 cm
Cumple
Cuantía geométrica mínima:
Criterio de CYPE Ingenieros
Mínimo: 0.002
-En dirección X:
Calculado: 0.0021
Cumple
-En dirección Y:
Calculado: 0.0021
Cumple
Cuantía mínima necesaria por flexión:
Artículo 42.3.2 (norma EHE-98)
Calculado: 0.0011
-Armado inferior dirección X:
Mínimo: 0.0001
Cumple
-Armado inferior dirección Y:
Mínimo: 0.0005
Cumple
-Armado superior dirección X:
Mínimo: 0.0001
Cumple
-Armado superior dirección Y:
Mínimo: 0.0004
Cumple
Diámetro mínimo de las barras:
Recomendación del Artículo 59.8.2 (norma EHE-
Mínimo: 12 mm
-Parrilla inferior:
Calculado: 12 mm
Cumple
-Parrilla superior:
Calculado: 12 mm
Cumple
Separación máxima entre barras:
Artículo 59.8.2 (norma EHE-98)
Máximo: 30 cm
-Armado inferior dirección X:
Calculado: 12.5 cm
Cumple
-Armado inferior dirección Y:
Calculado: 12.5 cm
Cumple
-Armado superior dirección X:
Calculado: 12.5 cm
Cumple
-Armado superior dirección Y:
Calculado: 12.5 cm
Cumple
Separación mínima entre barras:
Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 10 cm
-Armado inferior dirección X:
Calculado: 12.5 cm
Cumple
-Armado inferior dirección Y:
Calculado: 12.5 cm
Cumple
-Armado superior dirección X:
Calculado: 12.5 cm
Cumple
-Armado superior dirección Y:
Calculado: 12.5 cm
Cumple
Longitud de anclaje:
Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 15 cm
-Armado inf. dirección X hacia der:
Calculado: 15 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 15 cm
Cumple
-Armado inf. dirección Y hacia arriba:
Calculado: 100 cm
Cumple
-Armado inf. dirección Y hacia abajo:
Calculado: 100 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 15 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 15 cm
Cumple
-Armado sup. dirección Y hacia arriba:
Calculado: 100 cm
Cumple
-Armado sup. dirección Y hacia abajo:
Calculado: 100 cm
Cumple
Longitud mínima de las patillas: Mínimo: 12 cm
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
42/106
-Armado inf. dirección X hacia der:
Calculado: 15 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 15 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 15 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 15 cm
Cumple
Se cumplen todas las comprobaciones
Información adicional:
- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))
- Relación rotura pésima (En dirección X): 0.04
- Relación rotura pésima (En dirección Y): 0.30
- Cortante de agotamiento (En dirección X): 77.90 t
- Cortante de agotamiento (En dirección Y): 39.65 t
2.2 Nave de Proceso
2.2.1 Estructura
La estructura de la Nave de Proceso se ha calculado empleando perfiles de
acero laminado S 275 JR. Está formada por dos partes; la primera está
constituida por 8 pórticos rígidos a un agua de 20 m de luz, con 8 m de altura
en los pilares aguas abajo y 10 m en los pilares aguas arriba; y la segunda por
3 pórticos rígidos a un agua de 10 m de luz, con 6 m de altura en los pilares
aguas abajo y 7 m en los pilares aguas arriba, en todos los casos respecto a la
solera terminada (ver figura).
Los pilares irán empotrados en su base a la cimentación mediante placas
de anclaje, con una separación entre pórticos 5 m.
Las correas están formadas por perfiles laminados en caliente IPE 140
separados entre sí 1 m, que reciben la carga de la cubierta.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
43/106
Fig. 5: Detalle de un pórtico intermedio y las correas (cotas en m)
La tipología de la estructura se puede ver de una forma más clara en la
siguiente figura, en la que se muestra una representación 3D de la misma:
Fig. 6: Vista 3D de la estructura metálica
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
44/106
• Acciones adoptadas en el cálculo
Todos los valores de las acciones que se han aplicado en el cálculo de
cada uno de los elementos resistentes se ajustan a lo prescrito en la Norma
“CTE DB SE-AE Acciones en la Edificación”, siendo sus valores los siguientes:
Acciones Gravitatorias
Concargas Peso Propio
Cubierta de chapa: 20 kg/m²
Estructura: 7.850 kg/m³
Carga Permanente -
Sobrecargas De Uso 40 kg/m2
De Nieve H: 300 m 20 kg/m²
Acciones del Viento Según CTE DB SE-AE
Altura Coronación < 10 m. Situación Expuesta.
Acciones Térmicas No se necesitan juntas de dilatación
Acciones Reológicas
No han sido consideradas por tratarse de una estruc-tura toda ella realizada con materiales metálicos y
ser, por tanto, despreciables los efectos de las mismas, según indica la Norma CTE DB SE-A.
Acciones Sísmicas
No han sido consideradas por ser la aceleración básica menor que la mínima exigida para realizar los
cálculos sísmicos según indica el CTE
• Especificaciones de los materiales
El acero empleado en la estructura será del tipo S 275 JR con límite
elástico σe = 275 N/mm2, la estructura secundaria (correas) será del tipo S 275
JR con límite elástico σe = 275 N/mm2. La resistencia de cálculo del acero viene
fijada por la expresión: σu = σe / γa, donde γa es el coeficiente de minoración,
con valor 1, pues el acero tendrá el límite elástico mínimo garantizado.
Las constantes elásticas del acero serán las siguientes:
Módulo de elasticidad E = 2100000 kg/cm2
Módulo de elasticidad transversal G = 810000 kg/cm2
Coeficiente de Poisson µ = 0.30
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
45/106
El coeficiente de dilatación térmica del acero para el cálculo de esfuerzos,
tensiones y deformaciones se tomará: αt = 0.000012 m/m°C.
• Métodos de cálculo e hipótesis de carga
El cálculo se ha realizado mediante programa informático comercial
“METAL 3D” de la casa especializada “CYPE INGENIEROS, S.A.”,
comprobándose la estabilidad estática y elástica, las tensiones y las
deformaciones.
Dichos cálculos están basados en las leyes de la mecánica y en la teoría
de la elasticidad, admitiendo, en alguna ocasión y de modo implícito, la
existencia de estados tensionales plásticos locales.
Las hipótesis de carga utilizadas son las establecidas en el CTE DB SE-AE y
las acciones características las prescritas en el CTE DB SE-AE. Las acciones
consideradas en este cálculo han sido las siguientes:
Acciones constantes:
- el peso propio;
- la carga permanente;
- las acciones térmicas;
Acciones variables:
- las sobrecargas de uso o explotación;
- las acciones de viento;
- la sobrecarga producida por la nieve;
Los coeficientes de ponderación según la hipótesis de carga, la clase de
acción y el efecto favorable o desfavorable de la acción sobre la estabilidad o
las tensiones se dan en el cuadro siguiente:
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
46/106
• Resultados en el cálculo de esfuerzos sobre la estructura
Se muestran a continuación los resultados del cálculo sobre la estructura
principal y correas. No se incluyen en estos listados los resultados sobre las
cruces de San Andrés.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
47/106
Resultados de cálculo en pórtico hastial delantero 1.- Barras: Descripción
Barras Material Perfil Peso Volumen Longitud Co.pand.xy Co.pand.xz Dist.arr.sup. Dist.arr.inf.
(kp) (m³) (m) (m) (m)
1/2 Acero (S275) HE 220 A (HEA) 403.80 0.051 8.00 0.70 1.33 8.00 8.00
2/4 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
3/4 Acero (S275) HE 240 A (HEA) 504.91 0.064 8.38 0.70 1.30 8.38 -
4/6 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
5/6 Acero (S275) HE 240 A (HEA) 527.52 0.067 8.75 0.70 1.30 8.75 -
6/8 Acero (S275) IPE 160 (IPE) 79.29 0.010 5.02 0.05 0.73 1.00 5.02
7/8 Acero (S275) HE 240 A (HEA) 557.66 0.071 9.25 0.70 1.30 9.25 -
8/10 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
9/10 Acero (S275) HE 240 A (HEA) 580.27 0.074 9.63 0.70 1.30 9.63 -
10/13 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
11/12 Acero (S275) HE 240 A (HEA) 422.02 0.054 7.00 0.70 1.22 7.00 7.00
12/13 Acero (S275) HE 240 A (HEA) 180.86 0.023 3.00 2.33 1.80 3.00 3.00
15/12 Acero (S275) IPE 180 (IPE) 94.28 0.012 5.02 0.10 0.76 1.00 5.02
14/15 Acero (S275) HE 220 A (HEA) 328.09 0.042 6.50 0.70 1.23 6.50 -
17/15 Acero (S275) IPE 180 (IPE) 94.28 0.012 5.02 0.10 0.76 1.00 5.02
16/17 Acero (S275) HE 220 A (HEA) 302.85 0.039 6.00 0.70 1.25 6.00 6.00
2.- Cargas (Barras)
Barras Hipót. Tipo Cargas Dirección
P1 P2 L1 (m) L2 (m) X Y Z
1/2 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000
1/2 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
1/2 3 (V 1) Uniforme 0.147 t/m - - - 0.000 1.000 0.000
1/2 3 (V 1) Uniforme 0.175 t/m - - - -1.000 0.000 0.000
1/2 4 (V 2) Uniforme 0.147 t/m - - - 0.000 1.000 0.000
1/2 4 (V 2) Uniforme 0.175 t/m - - - -1.000 0.000 0.000
1/2 5 (V 3) Uniforme 0.248 t/m - - - 0.000 -1.000 0.000
1/2 5 (V 3) Uniforme 0.117 t/m - - - 0.000 0.000 -1.000
1/2 5 (V 3) Uniforme 0.117 t/m - - - 1.000 0.000 0.000
1/2 6 (V 4) Uniforme 0.067 t/m - - - 0.000 -1.000 0.000
1/2 6 (V 4) Uniforme 0.074 t/m - - - -1.000 0.000 0.000
1/2 7 (V 5) Uniforme 0.067 t/m - - - 0.000 -1.000 0.000
1/2 7 (V 5) Uniforme 0.074 t/m - - - -1.000 0.000 0.000
1/2 8 (V 6) Uniforme 0.104 t/m - - - 0.000 -1.000 0.000
1/2 8 (V 6) Uniforme 0.073 t/m - - - -1.000 0.000 0.000
2/4 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
2/4 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
2/4 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
2/4 3 (V 1) Trapez. 0.340 t/m 0.340 t/m 0.000 2.010 0.000 -0.100 0.995
2/4 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 2.010 3.769 0.000 -0.100 0.995
2/4 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 2.010 0.000 0.100 -0.995
2/4 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 2.010 3.769 0.000 0.100 -0.995
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
48/106
2/4 5 (V 3) Trapez. 0.342 t/m 0.342 t/m 0.000 3.769 0.000 -0.100 0.995
2/4 5 (V 3) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
2/4 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
2/4 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
2/4 8 (V 6) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
2/4 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
2/4 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
2/4 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
3/4 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
3/4 3 (V 1) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
3/4 4 (V 2) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
3/4 5 (V 3) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
3/4 6 (V 4) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
3/4 7 (V 5) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
3/4 8 (V 6) Uniforme 0.146 t/m - - - -1.000 0.000 0.000
4/6 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
4/6 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
4/6 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
4/6 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995
4/6 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995
4/6 5 (V 3) Trapez. 0.342 t/m 0.342 t/m 0.000 1.256 0.000 -0.100 0.995
4/6 5 (V 3) Trapez. 0.299 t/m 0.299 t/m 1.256 3.769 0.000 -0.100 0.995
4/6 5 (V 3) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
4/6 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
4/6 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
4/6 8 (V 6) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
4/6 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
4/6 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
4/6 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
5/6 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
5/6 3 (V 1) Uniforme 0.295 t/m - - - -1.000 0.000 0.000
5/6 4 (V 2) Uniforme 0.295 t/m - - - -1.000 0.000 0.000
5/6 5 (V 3) Uniforme 0.273 t/m - - - 1.000 0.000 0.000
5/6 6 (V 4) Uniforme 0.295 t/m - - - -1.000 0.000 0.000
5/6 7 (V 5) Uniforme 0.295 t/m - - - -1.000 0.000 0.000
5/6 8 (V 6) Uniforme 0.170 t/m - - - -1.000 0.000 0.000
6/8 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
6/8 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
6/8 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
6/8 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 5.025 0.000 -0.100 0.995
6/8 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 5.025 0.000 0.100 -0.995
6/8 5 (V 3) Trapez. 0.299 t/m 0.299 t/m 0.000 5.025 0.000 -0.100 0.995
6/8 5 (V 3) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
6/8 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 5.025 0.000 -0.100 0.995
6/8 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 5.025 0.000 -0.100 0.995
6/8 8 (V 6) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
6/8 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
49/106
6/8 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
6/8 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
7/8 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
7/8 3 (V 1) Uniforme 0.295 t/m - - - -1.000 0.000 0.000
7/8 4 (V 2) Uniforme 0.295 t/m - - - -1.000 0.000 0.000
7/8 5 (V 3) Uniforme 0.273 t/m - - - 1.000 0.000 0.000
7/8 6 (V 4) Uniforme 0.295 t/m - - - -1.000 0.000 0.000
7/8 7 (V 5) Uniforme 0.295 t/m - - - -1.000 0.000 0.000
7/8 8 (V 6) Uniforme 0.170 t/m - - - -1.000 0.000 0.000
8/10 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
8/10 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
8/10 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
8/10 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995
8/10 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995
8/10 5 (V 3) Trapez. 0.299 t/m 0.299 t/m 0.000 2.513 0.000 -0.100 0.995
8/10 5 (V 3) Trapez. 0.351 t/m 0.351 t/m 2.513 3.769 0.000 -0.100 0.995
8/10 5 (V 3) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
8/10 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
8/10 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
8/10 8 (V 6) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
8/10 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
8/10 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
8/10 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
9/10 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
9/10 3 (V 1) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
9/10 4 (V 2) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
9/10 5 (V 3) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
9/10 6 (V 4) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
9/10 7 (V 5) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
9/10 8 (V 6) Uniforme 0.146 t/m - - - -1.000 0.000 0.000
10/13 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
10/13 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
10/13 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
10/13 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995
10/13 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995
10/13 5 (V 3) Trapez. 0.351 t/m 0.351 t/m 0.000 3.769 0.000 -0.100 0.995
10/13 5 (V 3) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
10/13 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 1.759 0.000 -0.100 0.995
10/13 6 (V 4) Trapez. 0.479 t/m 0.479 t/m 1.759 3.769 0.000 -0.100 0.995
10/13 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 1.759 0.000 -0.100 0.995
10/13 7 (V 5) Trapez. 0.479 t/m 0.479 t/m 1.759 3.769 0.000 -0.100 0.995
10/13 8 (V 6) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
10/13 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
10/13 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
10/13 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
11/12 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
11/12 3 (V 1) Uniforme 0.117 t/m - - - -1.000 0.000 0.000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
50/106
11/12 3 (V 1) Uniforme 0.097 t/m - - - -1.000 0.000 0.000
11/12 4 (V 2) Uniforme 0.097 t/m - - - -1.000 0.000 0.000
11/12 4 (V 2) Uniforme 0.117 t/m - - - -1.000 0.000 0.000
11/12 5 (V 3) Uniforme 0.117 t/m - - - 1.000 0.000 0.000
11/12 5 (V 3) Uniforme 0.156 t/m - - - 1.000 0.000 0.000
11/12 6 (V 4) Uniforme 0.156 t/m - - - -1.000 0.000 0.000
11/12 6 (V 4) Uniforme 0.117 t/m - - - -1.000 0.000 0.000
11/12 7 (V 5) Uniforme 0.117 t/m - - - -1.000 0.000 0.000
11/12 7 (V 5) Uniforme 0.156 t/m - - - -1.000 0.000 0.000
11/12 8 (V 6) Uniforme 0.073 t/m - - - -1.000 0.000 0.000
11/12 8 (V 6) Uniforme 0.097 t/m - - - -1.000 0.000 0.000
12/13 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
12/13 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
12/13 3 (V 1) Faja 0.067 t/m - 0.000 3.000 0.000 1.000 0.000
12/13 3 (V 1) Uniforme 0.117 t/m - - - -1.000 0.000 0.000
12/13 4 (V 2) Faja 0.067 t/m - 0.000 3.000 0.000 1.000 0.000
12/13 4 (V 2) Uniforme 0.097 t/m - - - -1.000 0.000 0.000
12/13 5 (V 3) Faja 0.248 t/m - 0.000 3.000 0.000 1.000 0.000
12/13 5 (V 3) Uniforme 0.117 t/m - - - 1.000 0.000 0.000
12/13 6 (V 4) Faja 0.147 t/m - 0.000 3.000 0.000 -1.000 0.000
12/13 6 (V 4) Uniforme 0.117 t/m - - - -1.000 0.000 0.000
12/13 7 (V 5) Faja 0.147 t/m - 0.000 3.000 0.000 -1.000 0.000
12/13 7 (V 5) Uniforme 0.117 t/m - - - -1.000 0.000 0.000
12/13 8 (V 6) Faja 0.104 t/m - 0.000 3.000 0.000 1.000 0.000
12/13 8 (V 6) Uniforme 0.073 t/m - - - -1.000 0.000 0.000
15/12 1 (PP 1) Uniforme 0.019 t/m - - - 0.000 0.000 -1.000
15/12 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
15/12 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
15/12 3 (V 1) Uniforme 0.097 t/m - - - 0.000 0.100 0.995
15/12 4 (V 2) Uniforme 0.092 t/m - - - 0.000 0.100 0.995
15/12 5 (V 3) Trapez. 0.299 t/m 0.299 t/m 0.000 0.000 0.000 0.100 0.995
15/12 5 (V 3) Trapez. 0.199 t/m 0.199 t/m 0.000 5.025 0.000 0.100 0.995
15/12 5 (V 3) Uniforme 0.029 t/m - - - 0.000 0.100 0.995
15/12 6 (V 4) Trapez. 0.120 t/m 0.120 t/m 0.000 5.025 0.000 0.100 0.995
15/12 7 (V 5) Trapez. 0.003 t/m 0.003 t/m 0.000 5.025 0.000 -0.100 -0.995
15/12 8 (V 6) Uniforme 0.127 t/m - - - 0.000 0.100 0.995
15/12 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
15/12 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
15/12 11 (N 3) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
14/15 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000
14/15 3 (V 1) Uniforme 0.194 t/m - - - -1.000 0.000 0.000
14/15 4 (V 2) Uniforme 0.194 t/m - - - -1.000 0.000 0.000
14/15 5 (V 3) Uniforme 0.312 t/m - - - 1.000 0.000 0.000
14/15 6 (V 4) Uniforme 0.312 t/m - - - -1.000 0.000 0.000
14/15 7 (V 5) Uniforme 0.312 t/m - - - -1.000 0.000 0.000
14/15 8 (V 6) Uniforme 0.195 t/m - - - -1.000 0.000 0.000
17/15 1 (PP 1) Uniforme 0.019 t/m - - - 0.000 0.000 -1.000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
51/106
17/15 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
17/15 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
17/15 3 (V 1) Uniforme 0.097 t/m - - - 0.000 0.100 0.995
17/15 4 (V 2) Uniforme 0.092 t/m - - - 0.000 0.100 0.995
17/15 5 (V 3) Trapez. 0.299 t/m 0.299 t/m 0.000 5.025 0.000 0.100 0.995
17/15 5 (V 3) Uniforme 0.029 t/m - - - 0.000 0.100 0.995
17/15 6 (V 4) Trapez. 0.340 t/m 0.340 t/m 0.000 2.010 0.000 0.100 0.995
17/15 6 (V 4) Trapez. 0.120 t/m 0.120 t/m 2.010 5.025 0.000 0.100 0.995
17/15 7 (V 5) Trapez. 0.003 t/m 0.003 t/m 0.000 2.010 0.000 -0.100 -0.995
17/15 7 (V 5) Trapez. 0.003 t/m 0.003 t/m 2.010 5.025 0.000 -0.100 -0.995
17/15 8 (V 6) Uniforme 0.127 t/m - - - 0.000 0.100 0.995
17/15 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
17/15 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
17/15 11 (N 3) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
16/17 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000
16/17 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
16/17 3 (V 1) Uniforme 0.067 t/m - - - 0.000 1.000 0.000
16/17 3 (V 1) Uniforme 0.097 t/m - - - -1.000 0.000 0.000
16/17 4 (V 2) Uniforme 0.067 t/m - - - 0.000 1.000 0.000
16/17 4 (V 2) Uniforme 0.097 t/m - - - -1.000 0.000 0.000
16/17 5 (V 3) Uniforme 0.248 t/m - - - 0.000 1.000 0.000
16/17 5 (V 3) Uniforme 0.156 t/m - - - 1.000 0.000 0.000
16/17 6 (V 4) Uniforme 0.147 t/m - - - 0.000 -1.000 0.000
16/17 6 (V 4) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
16/17 7 (V 5) Uniforme 0.147 t/m - - - 0.000 -1.000 0.000
16/17 7 (V 5) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
16/17 8 (V 6) Uniforme 0.104 t/m - - - 0.000 1.000 0.000
16/17 8 (V 6) Uniforme 0.097 t/m - - - -1.000 0.000 0.000 3.- Desplazamientos
Nudos Descripción DESPLAZAMIENTOS (EJES GENERALES)
DX (m) DY (m) DZ (m) GX (rad) GY (rad) GZ (rad)
1 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
2 Envolvente (Desplazam.) -0.0166 -0.0174 0.0000 -0.0009 -0.0001 -0.0012
0.0165 0.0126 0.0000 0.0020 0.0013 0.0008
3 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
4 Envolvente (Desplazam.) -0.0290 -0.0174 -0.0001 -0.0007 -0.0024 -0.0008
0.0290 0.0126 0.0000 0.0009 0.0035 0.0010
5 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
6 Envolvente (Desplazam.) -0.0392 -0.0174 -0.0001 -0.0011 -0.0031 -0.0009
0.0392 0.0126 0.0000 0.0012 0.0055 0.0013
7 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
52/106
8 Envolvente (Desplazam.) -0.0439 -0.0174 -0.0001 -0.0005 -0.0030 -0.0009
0.0438 0.0126 0.0000 0.0010 0.0057 0.0013
9 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
10 Envolvente (Desplazam.) -0.0383 -0.0174 -0.0001 -0.0005 -0.0023 -0.0008
0.0383 0.0125 0.0000 0.0010 0.0037 0.0013
11 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
12 Envolvente (Desplazam.) -0.0277 -0.0126 -0.0001 -0.0016 -0.0015 -0.0026
0.0317 0.0083 0.0000 0.0020 0.0039 0.0021
13 Envolvente (Desplazam.) -0.0279 -0.0174 -0.0001 -0.0011 -0.0014 -0.0012
0.0281 0.0125 0.0000 0.0026 0.0024 0.0007
14 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
15 Envolvente (Desplazam.) -0.0327 -0.0126 -0.0001 -0.0003 -0.0056 -0.0012
0.0329 0.0083 0.0000 0.0005 0.0053 0.0011
16 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
17 Envolvente (Desplazam.) -0.0179 -0.0126 0.0000 -0.0013 -0.0019 -0.0016
0.0179 0.0083 0.0000 0.0023 0.0018 0.0017 4.- Reacciones
Nudos Descripción REACCIONES (EJES GENERALES)
RX (t) RY (t) RZ (t) MX (t�m) MY (t�m) MZ (t�m)
1 Envolvente (Cim.equil.) -1.0133 -1.3468 -0.3702 -3.3526 -2.0415 -0.0004
1.1994 1.9378 1.5752 3.0297 1.7054 0.0005
1 Envolvente (Cim.tens.terr.) -0.6319 -0.8366 0.0774 -2.1158 -1.2721 -0.0002
0.7500 1.2193 1.0971 1.8811 1.0672 0.0003
3 Envolvente (Cim.equil.) -2.6256 -0.1827 -1.4646 -1.1935 -7.2631 -0.0006
2.2230 0.2623 2.5810 0.8414 6.5631 0.0006
3 Envolvente (Cim.tens.terr.) -1.5823 -0.1158 -0.4859 -0.7426 -4.3774 -0.0004
1.4512 0.1630 1.7918 0.5314 4.2728 0.0003
5 Envolvente (Cim.equil.) -3.1894 -0.1445 -1.8595 -1.0283 -9.1472 -0.0007
3.0257 0.2083 3.2866 0.7221 8.3312 0.0006
5 Envolvente (Cim.tens.terr.) -1.8997 -0.0878 -0.6358 -0.6536 -5.4465 -0.0005
1.9913 0.1341 2.2882 0.4446 5.4964 0.0003
7 Envolvente (Cim.equil.) -3.2627 -0.1484 -1.7565 -0.9908 -9.5802 -0.0007
3.0652 0.1986 3.2786 0.7284 8.6494 0.0006
7 Envolvente (Cim.tens.terr.) -1.9544 -0.0969 -0.5675 -0.6107 -5.7282 -0.0005
2.0065 0.1215 2.2807 0.4687 5.6834 0.0003
9 Envolvente (Cim.equil.) -2.7933 -0.1255 -1.2015 -0.8570 -8.2000 -0.0007
2.3400 0.1586 2.5938 0.6513 7.2232 0.0005
9 Envolvente (Cim.tens.terr.) -1.7006 -0.0784 -0.3071 -0.5369 -4.9806 -0.0004
1.5101 0.0996 1.7958 0.4078 4.6662 0.0003
11 Envolvente (Cim.equil.) -2.5198 -0.6373 -1.2796 -2.5612 -5.2961 -0.0017
2.2282 0.5350 2.3206 1.6913 3.8503 0.0020
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
53/106
11 Envolvente (Cim.tens.terr.) -1.5736 -0.3907 -0.3813 -1.6321 -3.3057 -0.0010
1.3930 0.3474 1.6003 1.0393 2.4081 0.0013
14 Envolvente (Cim.equil.) -2.9166 -0.2125 -1.8763 -1.0790 -7.3292 -0.0006
2.1593 0.3188 2.2232 0.7169 6.3515 0.0007
14 Envolvente (Cim.tens.terr.) -1.8092 -0.1325 -0.8397 -0.6766 -4.5539 -0.0004
1.3670 0.2000 1.5549 0.4477 4.0050 0.0004
16 Envolvente (Cim.equil.) -1.2293 -1.4045 -0.9106 -3.2037 -2.3615 -0.0010
1.3144 1.4098 1.4251 2.0338 2.0061 0.0010
16 Envolvente (Cim.tens.terr.) -0.7655 -0.8977 -0.3049 -1.9768 -1.4691 -0.0007
0.8227 0.8679 0.9804 1.3097 1.2576 0.0006 5.- Esfuerzos
Barras Esf. ESFUERZOS (EJES LOCALES) (t)(t�m)
0 L 1/8 L 1/4 L 3/8 L 1/2 L 5/8 L 3/4 L 7/8 L 1 L
1/2 0.000 m 1.000 m 2.000 m 3.000 m 4.000 m 5.000 m 6.000 m 7.000 m 8.000 m
Envolvente (Acero laminado)
N- -1.4304 -1.2673 -1.1654 -1.0635 -0.9616 -0.8597 -0.7579 -0.6560 -0.5541
N+ 0.4603 0.5207 0.5810 0.6414 0.7018 0.7622 0.8226 0.9042 1.1262
Ty- -1.1242 -0.8617 -0.5992 -0.3582 -0.2397 -0.1302 -0.1051 -0.2806 -0.4561
Ty+ 0.9505 0.7750 0.5995 0.4240 0.2485 0.1913 0.4538 0.7163 0.9788
Tz- -1.8159 -1.4432 -1.0705 -0.6978 -0.3863 -0.2862 -0.1861 -0.3165 -0.5373
Tz+ 1.2645 1.0436 0.8228 0.6019 0.3811 0.1755 0.4446 0.8173 1.1900
Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005
Mt+ 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003
My- -3.1412 -1.7415 -1.1031 -0.5821 -0.6823 -0.9380 -0.9817 -0.7957 -0.6755
My+ 2.8450 1.6953 0.7583 0.6232 1.1416 1.2725 1.0458 0.5918 0.6140
Mz- -1.5983 -0.9218 -0.4061 -0.1510 -0.4825 -0.6398 -0.6285 -0.4347 -1.0188
Mz+ 1.9153 1.0561 0.3654 0.5896 0.7997 0.7369 0.5527 0.5164 0.3751
2/4 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.5658 -0.5555 -0.5453 -0.5350 -0.5247 -0.5145 -0.5042 -0.4942 -0.4896
N+ 1.2166 1.2198 1.2230 1.2262 1.2294 1.2326 1.2358 1.2395 1.2485
Ty- -0.0623 -0.0623 -0.0623 -0.0623 -0.0623 -0.0623 -0.0623 -0.0623 -0.0623
Ty+ 0.0493 0.0493 0.0493 0.0493 0.0493 0.0493 0.0493 0.0493 0.0493
Tz- -0.4580 -0.3375 -0.2779 -0.2933 -0.3229 -0.4089 -0.4950 -0.6606 -0.8882
Tz+ 0.9323 0.7047 0.4772 0.2496 0.1710 0.2757 0.3805 0.4852 0.6019
Mt- -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003
Mt+ 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004
My- -0.6136 -0.4934 -0.4177 -0.3256 -0.2686 -0.2090 -0.1407 -0.3213 -0.5736
My+ 0.6754 0.2920 0.2058 0.2014 0.1787 0.1375 0.2153 0.4449 0.7381
Mz- -0.1233 -0.0940 -0.0646 -0.0353 -0.0060 -0.0187 -0.0418 -0.0650 -0.0882
Mz+ 0.0976 0.0744 0.0512 0.0279 0.0047 0.0236 0.0528 0.0821 0.1114
3/4 0.000 m 1.047 m 2.094 m 3.141 m 4.188 m 5.234 m 6.281 m 7.328 m 8.375 m
Envolvente (Acero laminado)
N- -2.3553 -2.2701 -2.1848 -2.0996 -2.0144 -1.9292 -1.8440 -1.7588 -1.6736
N+ 1.5306 1.5810 1.6315 1.6820 1.7325 1.7830 1.8335 1.8840 1.9345
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
54/106
Ty- -0.2463 -0.2463 -0.2463 -0.2463 -0.2463 -0.2463 -0.2463 -0.2463 -0.2463
Ty+ 0.1711 0.1711 0.1711 0.1711 0.1711 0.1711 0.1711 0.1711 0.1711
Tz- -2.4831 -2.1156 -1.7481 -1.3807 -1.0132 -0.6458 -0.7219 -1.0893 -1.4568
Tz+ 2.0753 1.7244 1.4841 1.2548 1.0255 0.7963 0.5670 0.4046 0.6649
Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005
Mt+ 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005
My- -6.8686 -4.4692 -2.4391 -1.1896 -1.8760 -2.3097 -2.3742 -2.2218 -2.4765
My+ 6.1286 4.2198 2.5414 1.1911 0.4518 1.3125 1.8039 1.8952 1.9242
Mz- -1.1201 -0.8623 -0.6044 -0.3468 -0.0930 -0.1074 -0.2865 -0.4657 -0.6449
Mz+ 0.7884 0.6092 0.4302 0.2513 0.0781 0.1691 0.4270 0.6848 0.9427
4/6 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.4126 -0.4023 -0.3921 -0.3818 -0.3715 -0.3613 -0.3510 -0.3448 -0.3416
N+ 1.2326 1.2358 1.2390 1.2423 1.2455 1.2487 1.2519 1.2596 1.2698
Ty- -0.0466 -0.0466 -0.0466 -0.0466 -0.0466 -0.0466 -0.0466 -0.0466 -0.0466
Ty+ 0.0354 0.0354 0.0354 0.0354 0.0354 0.0354 0.0354 0.0354 0.0354
Tz- -0.4550 -0.3345 -0.2210 -0.2093 -0.2407 -0.3411 -0.5305 -0.7280 -0.9254
Tz+ 0.7344 0.5068 0.2793 0.1689 0.1910 0.2958 0.4005 0.5053 0.6152
Mt- -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001
Mt+ 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002
My- -0.3692 -0.2886 -0.2214 -0.2355 -0.2200 -0.1096 -0.1714 -0.3857 -0.6474
My+ 0.3852 0.2441 0.1886 0.1717 0.1244 0.1123 0.2321 0.4476 0.7798
Mz- -0.0849 -0.0629 -0.0410 -0.0190 -0.0024 -0.0191 -0.0358 -0.0525 -0.0692
Mz+ 0.0643 0.0476 0.0309 0.0143 0.0029 0.0248 0.0468 0.0687 0.0906
5/6 0.000 m 1.094 m 2.187 m 3.281 m 4.375 m 5.469 m 6.562 m 7.656 m 8.750 m
Envolvente (Acero laminado)
N- -3.0022 -2.9132 -2.8242 -2.7351 -2.6461 -2.5571 -2.4681 -2.3791 -2.2900
N+ 1.9363 1.9891 2.0418 2.0946 2.1473 2.2001 2.2528 2.3056 2.3583
Ty- -0.1949 -0.1949 -0.1949 -0.1949 -0.1949 -0.1949 -0.1949 -0.1949 -0.1949
Ty+ 0.1364 0.1364 0.1364 0.1364 0.1364 0.1364 0.1364 0.1364 0.1364
Tz- -3.0244 -2.5765 -2.1286 -1.6808 -1.2329 -0.7850 -0.9632 -1.4472 -1.9311
Tz+ 2.8226 2.3386 1.8546 1.5417 1.2628 0.9839 0.7104 0.6092 0.8949
Mt- -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006
Mt+ 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007
My- -8.6747 -5.6215 -3.0386 -1.5792 -2.7122 -3.4067 -3.5931 -3.3247 -3.6528
My+ 7.7699 5.3272 3.1775 1.4768 0.6381 1.7318 2.3552 2.4691 2.7423
Mz- -0.9630 -0.7498 -0.5367 -0.3297 -0.1293 -0.0815 -0.2155 -0.3646 -0.5138
Mz+ 0.6794 0.5303 0.3813 0.2387 0.1020 0.1030 0.3161 0.5292 0.7424
6/8 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m
Envolvente (Acero laminado)
N- -0.3328 -0.3191 -0.3054 -0.2917 -0.2781 -0.2644 -0.2507 -0.2370 -0.2302
N+ 1.3577 1.3620 1.3663 1.3706 1.3748 1.3791 1.3834 1.3879 1.3993
Ty- -0.0128 -0.0128 -0.0128 -0.0128 -0.0128 -0.0128 -0.0128 -0.0128 -0.0128
Ty+ 0.0100 0.0100 0.0100 0.0100 0.0100 0.0100 0.0100 0.0100 0.0100
Tz- -0.6420 -0.4814 -0.3207 -0.1608 -0.1282 -0.3049 -0.5681 -0.8314 -1.0946
Tz+ 1.0113 0.7481 0.4848 0.2216 0.0929 0.2324 0.3809 0.5432 0.7055
Mt- 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
55/106
Mt+ 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
My- -0.5019 -0.2332 -0.2414 -0.4335 -0.4933 -0.3812 -0.1142 -0.3047 -0.6683
My+ 0.7248 0.2040 0.2077 0.2907 0.3085 0.2510 0.1399 0.3602 0.9341
Mz- -0.0301 -0.0221 -0.0141 -0.0061 -0.0020 -0.0064 -0.0127 -0.0190 -0.0253
Mz+ 0.0252 0.0189 0.0126 0.0062 0.0020 0.0100 0.0180 0.0260 0.0341
7/8 0.000 m 1.156 m 2.312 m 3.469 m 4.625 m 5.781 m 6.937 m 8.094 m 9.250 m
Envolvente (Acero laminado)
N- -2.9942 -2.9001 -2.8059 -2.7118 -2.6177 -2.5236 -2.4295 -2.3354 -2.2413
N+ 1.8412 1.8969 1.9527 2.0085 2.0642 2.1200 2.1758 2.2315 2.2873
Ty- -0.1872 -0.1872 -0.1872 -0.1872 -0.1872 -0.1872 -0.1872 -0.1872 -0.1872
Ty+ 0.1387 0.1387 0.1387 0.1387 0.1387 0.1387 0.1387 0.1387 0.1387
Tz- -3.0899 -2.6164 -2.1429 -1.6695 -1.1960 -0.7225 -0.9587 -1.4703 -1.9819
Tz+ 2.8609 2.3493 1.8376 1.5227 1.2278 0.9330 0.6432 0.5928 1.0020
Mt- -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006
Mt+ 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006
My- -9.0766 -5.7885 -3.0261 -1.6190 -2.8483 -3.4822 -3.5483 -3.2084 -3.5841
My+ 8.0699 5.4638 3.1851 1.3852 0.8345 1.9327 2.5053 2.5085 2.6427
Mz- -0.9320 -0.7156 -0.4992 -0.2859 -0.0836 -0.1205 -0.2809 -0.4413 -0.6017
Mz+ 0.6816 0.5212 0.3608 0.2034 0.0570 0.1501 0.3665 0.5829 0.7993
8/10 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.2009 -0.1906 -0.1804 -0.1701 -0.1598 -0.1496 -0.1393 -0.1302 -0.1266
N+ 1.4960 1.4992 1.5024 1.5056 1.5088 1.5120 1.5152 1.5202 1.5300
Ty- -0.0245 -0.0245 -0.0245 -0.0245 -0.0245 -0.0245 -0.0245 -0.0245 -0.0245
Ty+ 0.0142 0.0142 0.0142 0.0142 0.0142 0.0142 0.0142 0.0142 0.0142
Tz- -0.5085 -0.3880 -0.2675 -0.1967 -0.2082 -0.2787 -0.3962 -0.6304 -0.8646
Tz+ 0.8129 0.6155 0.4180 0.2206 0.1229 0.2123 0.3171 0.4218 0.5388
Mt- -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002
Mt+ 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001
My- -0.3944 -0.2745 -0.1947 -0.1845 -0.2420 -0.2046 -0.0962 -0.2506 -0.4730
My+ 0.5457 0.2239 0.1353 0.1495 0.1354 0.1149 0.1975 0.3697 0.6015
Mz- -0.0492 -0.0376 -0.0261 -0.0145 -0.0030 -0.0061 -0.0128 -0.0195 -0.0262
Mz+ 0.0281 0.0217 0.0153 0.0089 0.0024 0.0086 0.0201 0.0316 0.0432
9/10 0.000 m 1.203 m 2.406 m 3.609 m 4.813 m 6.016 m 7.219 m 8.422 m 9.625 m
Envolvente (Acero laminado)
N- -2.3651 -2.2672 -2.1693 -2.0713 -1.9734 -1.8755 -1.7776 -1.6797 -1.5817
N+ 1.2892 1.3472 1.4052 1.4633 1.5213 1.5793 1.6373 1.6954 1.7534
Ty- -0.1486 -0.1486 -0.1486 -0.1486 -0.1486 -0.1486 -0.1486 -0.1486 -0.1486
Ty+ 0.1177 0.1177 0.1177 0.1177 0.1177 0.1177 0.1177 0.1177 0.1177
Tz- -2.6353 -2.2130 -1.7907 -1.3684 -0.9462 -0.5239 -0.7495 -1.1718 -1.5941
Tz+ 2.1870 1.7717 1.4835 1.2201 0.9566 0.6931 0.4296 0.4809 0.9031
Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005
Mt+ 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006
My- -7.7405 -4.8341 -2.4154 -1.3758 -2.1649 -2.4997 -2.3466 -2.4093 -2.4570
My+ 6.7500 4.4960 2.5463 0.9930 0.8774 1.7516 2.1380 1.9960 1.9194
Mz- -0.8034 -0.6248 -0.4467 -0.2689 -0.0916 -0.0976 -0.2391 -0.3807 -0.5223
Mz+ 0.6107 0.4693 0.3284 0.1876 0.0473 0.0941 0.2696 0.4485 0.6273
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
56/106
10/13 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.2149 -0.2046 -0.1944 -0.1841 -0.1738 -0.1636 -0.1533 -0.1448 -0.1413
N+ 1.6528 1.6560 1.6592 1.6624 1.6656 1.6688 1.6720 1.6778 1.6876
Ty- -0.0469 -0.0469 -0.0469 -0.0469 -0.0469 -0.0469 -0.0469 -0.0469 -0.0469
Ty+ 0.0347 0.0347 0.0347 0.0347 0.0347 0.0347 0.0347 0.0347 0.0347
Tz- -0.4871 -0.3665 -0.2460 -0.1651 -0.2905 -0.5221 -0.7563 -1.0191 -1.3256
Tz+ 0.6490 0.4148 0.2074 0.1608 0.1848 0.2871 0.3918 0.4966 0.6013
Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005
Mt+ 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004
My- -0.2987 -0.1970 -0.2243 -0.2671 -0.2674 -0.1579 -0.2101 -0.3902 -0.6478
My+ 0.3003 0.1823 0.1636 0.1578 0.1649 0.1916 0.4122 0.7934 1.3130
Mz- -0.0858 -0.0638 -0.0417 -0.0197 -0.0022 -0.0177 -0.0340 -0.0504 -0.0667
Mz+ 0.0640 0.0477 0.0314 0.0151 0.0026 0.0247 0.0468 0.0688 0.0909
11/12 0.000 m 0.875 m 1.750 m 2.625 m 3.500 m 4.375 m 5.250 m 6.125 m 7.000 m
Envolvente (Acero laminado)
N- -2.1128 -2.0416 -1.9704 -1.8991 -1.8279 -1.7567 -1.6855 -1.6143 -1.5431
N+ 1.3531 1.3953 1.4375 1.4797 1.5219 1.5641 1.6063 1.6485 1.6907
Ty- -2.0887 -1.7304 -1.3721 -1.0138 -0.6796 -0.4565 -0.2334 -0.1478 -0.5061
Ty+ 2.3628 2.0044 1.6461 1.2878 0.9295 0.5712 0.2129 0.4468 0.8051
Tz- -0.5005 -0.5005 -0.5005 -0.5005 -0.5005 -0.5005 -0.5005 -0.5005 -0.5005
Tz+ 0.6003 0.6003 0.6003 0.6003 0.6003 0.6003 0.6003 0.6003 0.6003
Mt- -0.0019 -0.0019 -0.0019 -0.0019 -0.0019 -0.0019 -0.0019 -0.0019 -0.0019
Mt+ 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016
My- -2.3984 -1.9605 -1.5226 -1.0944 -0.6978 -1.0341 -1.5593 -2.0846 -2.6098
My+ 1.5922 1.2136 0.9746 0.7455 0.5373 0.3305 0.2305 0.6669 1.1048
Mz- -3.6090 -2.3349 -1.2482 -0.3646 -0.7950 -1.4450 -1.7943 -1.8175 -1.5398
Mz+ 4.9667 3.0624 1.4590 0.6133 1.3260 1.7144 1.8029 1.5863 1.1484
12/13 0.000 m 0.375 m 0.750 m 1.125 m 1.500 m 1.875 m 2.250 m 2.625 m 3.000 m
Envolvente (Acero laminado)
N- -0.9180 -0.8748 -0.8316 -0.7885 -0.7453 -0.7021 -0.6589 -0.6158 -0.5726
N+ 1.7074 1.7330 1.7586 1.7842 1.8098 1.8354 1.8609 1.8865 1.9121
Ty- -0.5139 -0.5797 -0.6455 -0.7113 -0.7771 -0.8429 -0.9087 -0.9746 -1.0404
Ty+ 0.8025 0.8684 0.9342 1.0000 1.0658 1.1316 1.1974 1.2632 1.3290
Tz- -0.7561 -0.8511 -0.9908 -1.1306 -1.2703 -1.4101 -1.5499 -1.6896 -1.8294
Tz+ 0.3894 0.3519 0.3143 0.2768 0.2393 0.2018 0.1642 0.1267 0.0892
Mt- -0.0034 -0.0034 -0.0034 -0.0034 -0.0034 -0.0034 -0.0034 -0.0034 -0.0034
Mt+ 0.0055 0.0055 0.0055 0.0055 0.0055 0.0055 0.0055 0.0055 0.0055
My- -2.6115 -2.3243 -1.9869 -1.5949 -1.1526 -0.6559 -0.5543 -0.6084 -0.6491
My+ 0.1820 0.2920 0.4965 0.6687 0.8111 0.9212 1.0014 1.0498 1.3136
Mz- -1.5399 -1.3356 -1.1075 -0.8537 -0.5763 -0.7969 -1.2331 -1.6950 -2.1805
Mz+ 1.1483 1.0569 0.9506 0.8284 0.6914 0.5383 0.3705 0.4223 0.7996
15/12 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m
Envolvente (Acero laminado)
N- -0.2592 -0.2453 -0.2313 -0.2174 -0.2035 -0.1895 -0.1756 -0.1616 -0.1477
N+ 1.2278 1.2322 1.2366 1.2411 1.2455 1.2499 1.2543 1.2588 1.2632
Ty- -0.0086 -0.0086 -0.0086 -0.0086 -0.0086 -0.0086 -0.0086 -0.0086 -0.0086
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
57/106
Ty+ 0.0103 0.0103 0.0103 0.0103 0.0103 0.0103 0.0103 0.0103 0.0103
Tz- -0.6747 -0.5115 -0.3483 -0.2326 -0.1745 -0.2045 -0.2472 -0.3791 -0.5497
Tz+ 0.8153 0.6447 0.4741 0.3188 0.2452 0.3641 0.5063 0.6485 0.7907
Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005
Mt+ 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005
My- -0.5916 -0.2883 -0.1252 -0.2722 -0.4113 -0.4390 -0.4575 -0.7018 -1.1520
My+ 0.7798 0.4212 0.2205 0.2378 0.2887 0.2963 0.3459 0.4504 0.6454
Mz- -0.0362 -0.0308 -0.0258 -0.0210 -0.0161 -0.0112 -0.0064 -0.0015 -0.0050
Mz+ 0.0468 0.0403 0.0338 0.0274 0.0209 0.0144 0.0080 0.0030 0.0074
14/15 0.000 m 0.813 m 1.625 m 2.438 m 3.250 m 4.063 m 4.875 m 5.688 m 6.500 m
Envolvente (Acero laminado)
N- -2.0343 -1.9789 -1.9236 -1.8682 -1.8128 -1.7575 -1.7021 -1.6467 -1.5914
N+ 1.8811 1.9139 1.9467 1.9795 2.0124 2.0452 2.0780 2.1108 2.1436
Ty- -0.2988 -0.2988 -0.2988 -0.2988 -0.2988 -0.2988 -0.2988 -0.2988 -0.2988
Ty+ 0.1994 0.1994 0.1994 0.1994 0.1994 0.1994 0.1994 0.1994 0.1994
Tz- -2.7393 -2.3590 -1.9788 -1.5985 -1.2183 -0.8380 -0.5007 -0.8810 -1.2612
Tz+ 2.0223 1.7846 1.5470 1.3093 1.0716 0.8340 0.5963 0.3587 0.3577
Mt- -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007
Mt+ 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006
My- -6.8810 -4.8160 -3.0476 -1.6250 -1.2670 -1.4329 -1.3022 -0.9225 -1.0152
My+ 5.9505 4.4078 3.0505 1.9180 0.9916 0.4540 0.9118 1.1231 1.0378
Mz- -1.0114 -0.7686 -0.5259 -0.2832 -0.0507 -0.1376 -0.2995 -0.4614 -0.6234
Mz+ 0.6725 0.5105 0.3485 0.1866 0.0256 0.2025 0.4452 0.6880 0.9308
17/15 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m
Envolvente (Acero laminado)
N- -0.1798 -0.1635 -0.1472 -0.1308 -0.1145 -0.0985 -0.0843 -0.0704 -0.0565
N+ 1.0654 1.0698 1.0742 1.0787 1.0831 1.0875 1.0919 1.0964 1.1008
Ty- -0.0234 -0.0234 -0.0234 -0.0234 -0.0234 -0.0234 -0.0234 -0.0234 -0.0234
Ty+ 0.0223 0.0223 0.0223 0.0223 0.0223 0.0223 0.0223 0.0223 0.0223
Tz- -0.6183 -0.4551 -0.2919 -0.1958 -0.1634 -0.2975 -0.5629 -0.8283 -1.0937
Tz+ 1.0294 0.7640 0.4986 0.2413 0.2544 0.3966 0.5388 0.6810 0.8295
Mt- -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004
Mt+ 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005
My- -0.6136 -0.4089 -0.3211 -0.3958 -0.4622 -0.3554 -0.1601 -0.4967 -0.9673
My+ 1.0257 0.5386 0.5274 0.4998 0.3864 0.2359 0.1243 0.3518 0.9521
Mz- -0.0557 -0.0410 -0.0263 -0.0126 -0.0074 -0.0144 -0.0284 -0.0424 -0.0564
Mz+ 0.0556 0.0416 0.0276 0.0136 0.0039 0.0177 0.0324 0.0470 0.0617
16/17 0.000 m 0.750 m 1.500 m 2.250 m 3.000 m 3.750 m 4.500 m 5.250 m 6.000 m
Envolvente (Acero laminado)
N- -1.2964 -1.2200 -1.1435 -1.0671 -0.9907 -0.9143 -0.8379 -0.7615 -0.6850
N+ 0.9506 0.9959 1.0412 1.0865 1.1317 1.1770 1.2223 1.2676 1.3129
Ty- -1.2318 -0.9685 -0.7053 -0.5267 -0.4176 -0.3085 -0.1994 -0.1140 -0.2563
Ty+ 1.1535 0.9780 0.8025 0.6270 0.4515 0.2760 0.3535 0.6168 0.8800
Tz- -1.3266 -1.1609 -0.9953 -0.8297 -0.6640 -0.4984 -0.4235 -0.7030 -0.9825
Tz+ 1.3147 1.0352 0.7557 0.5058 0.4194 0.3444 0.2693 0.1942 0.1285
Mt- -0.0010 -0.0010 -0.0010 -0.0010 -0.0010 -0.0010 -0.0010 -0.0010 -0.0010
Mt+ 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
58/106
My- -3.0128 -2.1341 -1.3747 -0.7653 -0.5459 -0.5839 -0.4207 -0.4950 -0.6136
My+ 1.9028 1.3924 0.9360 0.5576 0.2594 0.4610 0.7751 0.9601 1.0258
Mz- -1.8797 -1.2816 -0.7622 -0.3278 -0.1922 -0.4613 -0.6051 -0.6120 -0.4926
Mz+ 2.2164 1.4197 0.7494 0.4747 0.7093 0.7397 0.5815 0.5976 0.6260 6.- Tensiones
Barras TENSIÓN MÁXIMA
TENS. () APROV. (%) Pos. (m) N (t) Ty (t) Tz (t) Mt (t�m) My (t�m) Mz (t�m)
1/2 0.7818 78.18 0.000 -1.4019 0.9479 -1.8159 0.0002 -3.1412 1.9083
2/4 0.4696 46.96 0.000 0.0096 0.0175 -0.2470 0.0001 -0.6136 0.0345
3/4 0.5489 54.89 0.000 -1.6258 -0.0209 1.9425 0.0005 6.1281 -0.1113
4/6 0.4699 46.99 3.769 -0.3301 -0.0113 0.6101 0.0002 -0.6474 0.0219
5/6 0.7132 71.32 0.000 -1.7859 -0.0300 2.3784 0.0002 7.7699 -0.1351
6/8 0.6225 62.25 5.025 -0.2228 -0.0073 0.6514 0.0000 -0.6683 0.0182
7/8 0.7610 76.10 0.000 -1.8425 -0.0138 2.4072 0.0000 8.0699 -0.0838
8/10 0.3446 34.46 3.769 -0.1183 -0.0115 0.5266 -0.0002 -0.4730 0.0209
9/10 0.6683 66.83 0.000 -1.7880 -0.0286 2.0105 -0.0003 6.7500 -0.1290
10/13 0.5218 52.18 3.769 1.6784 0.0341 -1.2247 -0.0004 1.3130 -0.0652
11/12 0.9215 92.15 0.000 0.1153 2.3608 0.5871 -0.0007 1.5630 4.9597
12/13 0.4240 42.40 3.000 1.9121 1.3290 -0.0936 0.0014 1.0948 -2.1805
15/12 0.7309 73.09 5.025 0.2313 -0.0041 0.7907 -0.0002 -1.1520 0.0040
14/15 0.6144 61.44 0.000 -0.8330 0.0157 2.0223 -0.0003 5.9505 0.0706
17/15 0.6330 63.30 5.025 -0.0560 0.0092 0.8232 0.0000 -0.9673 -0.0278
16/17 0.6256 62.56 0.000 0.3106 1.1477 1.3147 0.0009 1.7221 2.2002
Resultados de cálculo en pórtico hastial trasero 1.- Barras: Descripción
Barras Material Perfil Peso Volumen Longitud Co.pand.xy Co.pand.xz Dist.arr.sup. Dist.arr.inf.
(kp) (m³) (m) (m) (m)
75/76 Acero (S275) HE 220 A (HEA) 403.80 0.051 8.00 0.70 1.33 8.00 8.00
76/78 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
77/78 Acero (S275) HE 240 A (HEA) 504.91 0.064 8.38 0.70 1.30 8.38 -
78/80 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
79/80 Acero (S275) HE 240 A (HEA) 527.52 0.067 8.75 0.70 1.30 8.75 -
80/82 Acero (S275) IPE 160 (IPE) 79.29 0.010 5.02 0.05 0.73 1.00 5.02
81/82 Acero (S275) HE 240 A (HEA) 557.66 0.071 9.25 0.70 1.30 9.25 -
82/84 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
83/84 Acero (S275) HE 240 A (HEA) 580.27 0.074 9.63 0.70 1.30 9.63 -
84/86 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77
85/86 Acero (S275) HE 240 A (HEA) 602.88 0.077 10.00 0.70 1.22 10.00 10.00
2.- Cargas (Barras)
Barras Hipót. Tipo Cargas Dirección
P1 P2 L1 (m) L2 (m) X Y Z
75/76 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
59/106
75/76 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
75/76 3 (V 1) Uniforme 0.147 t/m - - - 0.000 1.000 0.000
75/76 3 (V 1) Uniforme 0.175 t/m - - - 1.000 0.000 0.000
75/76 4 (V 2) Uniforme 0.147 t/m - - - 0.000 1.000 0.000
75/76 4 (V 2) Uniforme 0.175 t/m - - - 1.000 0.000 0.000
75/76 5 (V 3) Uniforme 0.104 t/m - - - 0.000 -1.000 0.000
75/76 5 (V 3) Uniforme 0.073 t/m - - - 1.000 0.000 0.000
75/76 6 (V 4) Uniforme 0.067 t/m - - - 0.000 -1.000 0.000
75/76 6 (V 4) Uniforme 0.117 t/m - - - 1.000 0.000 0.000
75/76 7 (V 5) Uniforme 0.067 t/m - - - 0.000 -1.000 0.000
75/76 7 (V 5) Uniforme 0.117 t/m - - - 1.000 0.000 0.000
75/76 8 (V 6) Uniforme 0.248 t/m - - - 0.000 -1.000 0.000
75/76 8 (V 6) Uniforme 0.117 t/m - - - -1.000 0.000 0.000
76/78 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
76/78 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
76/78 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
76/78 3 (V 1) Trapez. 0.340 t/m 0.340 t/m 0.000 2.010 0.000 -0.100 0.995
76/78 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 2.010 3.769 0.000 -0.100 0.995
76/78 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 2.010 0.000 0.100 -0.995
76/78 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 2.010 3.769 0.000 0.100 -0.995
76/78 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
76/78 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
76/78 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
76/78 8 (V 6) Trapez. 0.342 t/m 0.342 t/m 0.000 3.769 0.000 -0.100 0.995
76/78 8 (V 6) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
76/78 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
76/78 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
76/78 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
77/78 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
77/78 3 (V 1) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
77/78 4 (V 2) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
77/78 5 (V 3) Uniforme 0.146 t/m - - - 1.000 0.000 0.000
77/78 6 (V 4) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
77/78 7 (V 5) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
77/78 8 (V 6) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
78/80 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
78/80 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
78/80 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
78/80 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995
78/80 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995
78/80 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
78/80 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
78/80 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
78/80 8 (V 6) Trapez. 0.342 t/m 0.342 t/m 0.000 1.256 0.000 -0.100 0.995
78/80 8 (V 6) Trapez. 0.299 t/m 0.299 t/m 1.256 3.769 0.000 -0.100 0.995
78/80 8 (V 6) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
78/80 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
60/106
78/80 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
78/80 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
79/80 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
79/80 3 (V 1) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
79/80 4 (V 2) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
79/80 5 (V 3) Uniforme 0.170 t/m - - - 1.000 0.000 0.000
79/80 6 (V 4) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
79/80 7 (V 5) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
79/80 8 (V 6) Uniforme 0.273 t/m - - - -1.000 0.000 0.000
80/82 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
80/82 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
80/82 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
80/82 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 5.025 0.000 -0.100 0.995
80/82 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 5.025 0.000 0.100 -0.995
80/82 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
80/82 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 5.025 0.000 -0.100 0.995
80/82 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 5.025 0.000 -0.100 0.995
80/82 8 (V 6) Trapez. 0.299 t/m 0.299 t/m 0.000 5.025 0.000 -0.100 0.995
80/82 8 (V 6) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
80/82 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
80/82 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
80/82 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
81/82 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
81/82 3 (V 1) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
81/82 4 (V 2) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
81/82 5 (V 3) Uniforme 0.170 t/m - - - 1.000 0.000 0.000
81/82 6 (V 4) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
81/82 7 (V 5) Uniforme 0.295 t/m - - - 1.000 0.000 0.000
81/82 8 (V 6) Uniforme 0.273 t/m - - - -1.000 0.000 0.000
82/84 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
82/84 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
82/84 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
82/84 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995
82/84 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995
82/84 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
82/84 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
82/84 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995
82/84 8 (V 6) Trapez. 0.299 t/m 0.299 t/m 0.000 2.513 0.000 -0.100 0.995
82/84 8 (V 6) Trapez. 0.351 t/m 0.351 t/m 2.513 3.769 0.000 -0.100 0.995
82/84 8 (V 6) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
82/84 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
82/84 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
82/84 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
83/84 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
83/84 3 (V 1) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
83/84 4 (V 2) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
83/84 5 (V 3) Uniforme 0.146 t/m - - - 1.000 0.000 0.000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
61/106
83/84 6 (V 4) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
83/84 7 (V 5) Uniforme 0.234 t/m - - - 1.000 0.000 0.000
83/84 8 (V 6) Uniforme 0.234 t/m - - - -1.000 0.000 0.000
84/86 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000
84/86 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000
84/86 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000
84/86 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995
84/86 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995
84/86 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995
84/86 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 1.759 0.000 -0.100 0.995
84/86 6 (V 4) Trapez. 0.479 t/m 0.479 t/m 1.759 3.769 0.000 -0.100 0.995
84/86 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 1.759 0.000 -0.100 0.995
84/86 7 (V 5) Trapez. 0.479 t/m 0.479 t/m 1.759 3.769 0.000 -0.100 0.995
84/86 8 (V 6) Trapez. 0.351 t/m 0.351 t/m 0.000 3.769 0.000 -0.100 0.995
84/86 8 (V 6) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995
84/86 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
84/86 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
84/86 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
85/86 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000
85/86 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000
85/86 3 (V 1) Faja 0.067 t/m - 0.000 10.000 0.000 1.000 0.000
85/86 3 (V 1) Uniforme 0.117 t/m - - - 1.000 0.000 0.000
85/86 4 (V 2) Faja 0.067 t/m - 0.000 10.000 0.000 1.000 0.000
85/86 4 (V 2) Uniforme 0.117 t/m - - - 1.000 0.000 0.000
85/86 5 (V 3) Faja 0.104 t/m - 0.000 10.000 0.000 1.000 0.000
85/86 5 (V 3) Uniforme 0.073 t/m - - - 1.000 0.000 0.000
85/86 6 (V 4) Faja 0.147 t/m - 0.000 10.000 0.000 -1.000 0.000
85/86 6 (V 4) Uniforme 0.175 t/m - - - 1.000 0.000 0.000
85/86 7 (V 5) Faja 0.147 t/m - 0.000 10.000 0.000 -1.000 0.000
85/86 7 (V 5) Uniforme 0.175 t/m - - - 1.000 0.000 0.000
85/86 8 (V 6) Faja 0.248 t/m - 0.000 10.000 0.000 1.000 0.000
85/86 8 (V 6) Uniforme 0.117 t/m - - - -1.000 0.000 0.000 3.- Desplazamientos
Nudos Descripción DESPLAZAMIENTOS (EJES GENERALES)
DX (m) DY (m) DZ (m) GX (rad) GY (rad) GZ (rad)
75 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
76 Envolvente (Desplazam.) -0.0167 -0.0269 0.0000 -0.0016 -0.0013 -0.0012
0.0165 0.0175 0.0000 0.0032 0.0001 0.0016
77 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
78 Envolvente (Desplazam.) -0.0291 -0.0270 -0.0001 -0.0009 -0.0036 -0.0013
0.0289 0.0174 0.0000 0.0014 0.0024 0.0012
79 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
62/106
80 Envolvente (Desplazam.) -0.0394 -0.0270 -0.0001 -0.0014 -0.0057 -0.0017
0.0391 0.0174 0.0000 0.0018 0.0031 0.0013
81 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
82 Envolvente (Desplazam.) -0.0440 -0.0270 -0.0001 -0.0008 -0.0058 -0.0017
0.0437 0.0174 0.0000 0.0015 0.0030 0.0013
83 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
84 Envolvente (Desplazam.) -0.0384 -0.0270 -0.0001 -0.0008 -0.0037 -0.0015
0.0382 0.0174 0.0000 0.0015 0.0023 0.0010
85 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
86 Envolvente (Desplazam.) -0.0278 -0.0271 -0.0001 -0.0011 -0.0018 -0.0012
0.0279 0.0174 0.0000 0.0031 0.0003 0.0016 4.- Reacciones
Nudos Descripción REACCIONES (EJES GENERALES)
RX (t) RY (t) RZ (t) MX (t�m) MY (t�m) MZ (t�m)
75 Envolvente (Cim.equil.) -1.2040 -1.4415 -0.5134 -3.6735 -1.7237 -0.0007
1.0151 1.9811 1.5073 3.5562 2.0497 0.0006
75 Envolvente (Cim.tens.terr.) -0.7528 -0.8959 -0.0124 -2.3149 -1.0781 -0.0005
0.6331 1.2461 1.0274 2.2108 1.2777 0.0004
77 Envolvente (Cim.equil.) -2.2410 -0.2565 -1.4915 -1.8512 -6.5379 -0.0008
2.6275 0.4072 2.5847 1.1765 7.2687 0.0008
77 Envolvente (Cim.tens.terr.) -1.4625 -0.1619 -0.5021 -1.1533 -4.2551 -0.0005
1.5834 0.2534 1.7944 0.7406 4.3823 0.0005
79 Envolvente (Cim.equil.) -3.0395 -0.2037 -1.8703 -1.5980 -8.3168 -0.0009
3.1869 0.3241 3.3022 1.0132 9.1372 0.0010
79 Envolvente (Cim.tens.terr.) -2.0004 -0.1249 -0.6406 -1.0089 -5.4862 -0.0005
1.8977 0.2063 2.2998 0.6269 5.4413 0.0007
81 Envolvente (Cim.equil.) -3.0747 -0.2003 -1.7460 -1.5136 -8.6458 -0.0008
3.2589 0.3005 3.3022 0.9947 9.5684 0.0009
81 Envolvente (Cim.tens.terr.) -2.0134 -0.1293 -0.5576 -0.9370 -5.6814 -0.0005
1.9510 0.1851 2.2976 0.6351 5.7205 0.0006
83 Envolvente (Cim.equil.) -2.3445 -0.1712 -1.1706 -1.3372 -7.2337 -0.0006
2.7895 0.2481 2.6319 0.8957 8.1853 0.0008
83 Envolvente (Cim.tens.terr.) -1.5138 -0.1067 -0.2824 -0.8368 -4.6738 -0.0004
1.6973 0.1556 1.8234 0.5594 4.9703 0.0005
85 Envolvente (Cim.equil.) -1.5581 -2.2233 -0.9660 -5.6258 -2.9645 -0.0008
1.2657 1.8581 1.8838 3.7075 3.1750 0.0007
85 Envolvente (Cim.tens.terr.) -0.9741 -1.3971 -0.2014 -3.4987 -1.8535 -0.0005
0.7900 1.1564 1.2784 2.3435 1.9809 0.0004 5.- Esfuerzos
Barras Esf. ESFUERZOS (EJES LOCALES) (t)(t�m)
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
63/106
0 L 1/8 L 1/4 L 3/8 L 1/2 L 5/8 L 3/4 L 7/8 L 1 L
75/76 0.000 m 1.000 m 2.000 m 3.000 m 4.000 m 5.000 m 6.000 m 7.000 m 8.000 m
Envolvente (Acero laminado)
N- -1.3668 -1.2649 -1.1630 -1.0611 -0.9592 -0.8573 -0.7554 -0.6536 -0.5517
N+ 0.5944 0.6548 0.7152 0.7756 0.8360 0.8963 0.9567 1.0171 1.0775
Ty- -0.9521 -0.7766 -0.6011 -0.4256 -0.2501 -0.1879 -0.4504 -0.7129 -0.9754
Ty+ 1.1285 0.8660 0.6035 0.3593 0.2374 0.1279 0.1030 0.2785 0.4540
Tz- -1.8566 -1.4839 -1.1112 -0.7385 -0.5601 -0.4600 -0.3599 -0.2946 -0.4861
Tz+ 1.3532 1.1324 0.9115 0.6907 0.4698 0.2490 0.4035 0.7762 1.1489
Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005
Mt+ 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007
My- -3.4421 -2.5338 -1.7216 -1.0280 -0.6032 -0.9097 -1.0041 -0.8688 -0.5739
My+ 3.3383 2.0999 1.0735 0.5457 1.0786 1.2506 1.0649 0.8266 1.0384
Mz- -1.9228 -1.0620 -0.3697 -0.5848 -0.7987 -0.7407 -0.5485 -0.5100 -0.3663
Mz+ 1.6155 0.9144 0.4011 0.1485 0.4817 0.6406 0.6310 0.4388 1.0069
76/78 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.4782 -0.4679 -0.4576 -0.4474 -0.4371 -0.4268 -0.4166 -0.4063 -0.4016
N+ 1.1684 1.1716 1.1748 1.1780 1.1812 1.1844 1.1876 1.1909 1.1997
Ty- -0.0520 -0.0520 -0.0520 -0.0520 -0.0520 -0.0520 -0.0520 -0.0520 -0.0520
Ty+ 0.0648 0.0648 0.0648 0.0648 0.0648 0.0648 0.0648 0.0648 0.0648
Tz- -0.4878 -0.4563 -0.4717 -0.4871 -0.5173 -0.6033 -0.6893 -0.7754 -0.9347
Tz+ 0.8858 0.6582 0.4307 0.2382 0.2699 0.3747 0.4794 0.5842 0.6889
Mt- -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004
Mt+ 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003
My- -1.0379 -0.8264 -0.6601 -0.4764 -0.2538 -0.2184 -0.2038 -0.4310 -0.7299
My+ 0.5738 0.3567 0.3291 0.2750 0.1915 0.1478 0.3389 0.6604 1.0452
Mz- -0.1026 -0.0781 -0.0536 -0.0293 -0.0050 -0.0248 -0.0553 -0.0858 -0.1164
Mz+ 0.1279 0.0973 0.0668 0.0365 0.0062 0.0199 0.0444 0.0690 0.0935
77/78 0.000 m 1.047 m 2.094 m 3.141 m 4.188 m 5.234 m 6.281 m 7.328 m 8.375 m
Envolvente (Acero laminado)
N- -2.3587 -2.2735 -2.1883 -2.1031 -2.0179 -1.9327 -1.8474 -1.7622 -1.6770
N+ 1.5559 1.6064 1.6569 1.7074 1.7579 1.8084 1.8589 1.9094 1.9599
Ty- -0.3821 -0.3821 -0.3821 -0.3821 -0.3821 -0.3821 -0.3821 -0.3821 -0.3821
Ty+ 0.2403 0.2403 0.2403 0.2403 0.2403 0.2403 0.2403 0.2403 0.2403
Tz- -2.0922 -1.7297 -1.4779 -1.2486 -1.0193 -0.7901 -0.5608 -0.4025 -0.6633
Tz+ 2.4848 2.1174 1.7499 1.3825 1.0150 0.6476 0.7088 1.0763 1.4437
Mt- -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007
Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008
My- -6.1052 -4.2028 -2.5309 -1.1937 -0.4545 -1.3170 -1.8103 -1.9035 -1.9876
My+ 6.8733 4.4720 2.4400 1.2049 1.9147 2.3661 2.4482 2.2501 2.4659
Mz- -1.7369 -1.3368 -0.9368 -0.5368 -0.1408 -0.1554 -0.4069 -0.6585 -0.9101
Mz+ 1.1024 0.8509 0.5993 0.3478 0.1003 0.2634 0.6634 1.0635 1.4635
78/80 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.3933 -0.3830 -0.3727 -0.3625 -0.3522 -0.3419 -0.3317 -0.3239 -0.3207
N+ 1.1500 1.1532 1.1564 1.1596 1.1628 1.1660 1.1692 1.1750 1.1853
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
64/106
Ty- -0.0378 -0.0378 -0.0378 -0.0378 -0.0378 -0.0378 -0.0378 -0.0378 -0.0378
Ty+ 0.0498 0.0498 0.0498 0.0498 0.0498 0.0498 0.0498 0.0498 0.0498
Tz- -0.4542 -0.3445 -0.3122 -0.3276 -0.3593 -0.4453 -0.5579 -0.7553 -0.9528
Tz+ 0.7070 0.4795 0.2561 0.2109 0.2515 0.3562 0.4610 0.5657 0.6705
Mt- -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002
Mt+ 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001
My- -0.5823 -0.4460 -0.3234 -0.2459 -0.2175 -0.1202 -0.2333 -0.4761 -0.7663
My+ 0.4474 0.2984 0.2406 0.1951 0.1226 0.1713 0.3537 0.6251 0.9354
Mz- -0.0688 -0.0509 -0.0331 -0.0153 -0.0030 -0.0264 -0.0499 -0.0733 -0.0968
Mz+ 0.0909 0.0674 0.0439 0.0205 0.0025 0.0204 0.0382 0.0560 0.0738
79/80 0.000 m 1.094 m 2.187 m 3.281 m 4.375 m 5.469 m 6.562 m 7.656 m 8.750 m
Envolvente (Acero laminado)
N- -3.0165 -2.9275 -2.8385 -2.7495 -2.6604 -2.5714 -2.4824 -2.3934 -2.3044
N+ 1.9472 1.9999 2.0527 2.1054 2.1582 2.2109 2.2637 2.3164 2.3692
Ty- -0.3035 -0.3035 -0.3035 -0.3035 -0.3035 -0.3035 -0.3035 -0.3035 -0.3035
Ty+ 0.1918 0.1918 0.1918 0.1918 0.1918 0.1918 0.1918 0.1918 0.1918
Tz- -2.8354 -2.3514 -1.8674 -1.5390 -1.2601 -0.9812 -0.7103 -0.6127 -0.8988
Tz+ 3.0223 2.5744 2.1265 1.6786 1.2307 0.7828 0.9517 1.4357 1.9197
Mt- -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009
Mt+ 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009
My- -7.7566 -5.3168 -3.1698 -1.4822 -0.6385 -1.7298 -2.3508 -2.4624 -2.8125
My+ 8.6649 5.6140 3.0335 1.5989 2.7560 3.4643 3.6646 3.3998 3.6628
Mz- -1.4972 -1.1652 -0.8333 -0.5081 -0.1887 -0.1043 -0.3065 -0.5163 -0.7261
Mz+ 0.9522 0.7424 0.5326 0.3295 0.1322 0.1624 0.4943 0.8263 1.1582
80/82 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m
Envolvente (Acero laminado)
N- -0.5451 -0.5314 -0.5177 -0.5040 -0.4903 -0.4766 -0.4629 -0.4492 -0.4399
N+ 1.2461 1.2504 1.2547 1.2589 1.2632 1.2675 1.2718 1.2760 1.2847
Ty- -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158
Ty+ 0.0148 0.0148 0.0148 0.0148 0.0148 0.0148 0.0148 0.0148 0.0148
Tz- -0.6417 -0.4810 -0.3204 -0.1903 -0.1994 -0.3329 -0.5853 -0.8485 -1.1118
Tz+ 0.9942 0.7309 0.4677 0.2044 0.1290 0.2686 0.4083 0.5649 0.7272
Mt- -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001
Mt+ 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
My- -0.5130 -0.3670 -0.3352 -0.4448 -0.4939 -0.3709 -0.1389 -0.3707 -0.7570
My+ 0.6812 0.2252 0.2554 0.3096 0.3099 0.2510 0.2249 0.4724 0.9767
Mz- -0.0399 -0.0300 -0.0201 -0.0101 -0.0020 -0.0113 -0.0206 -0.0298 -0.0391
Mz+ 0.0352 0.0259 0.0166 0.0073 0.0020 0.0097 0.0197 0.0296 0.0396
81/82 0.000 m 1.156 m 2.312 m 3.469 m 4.625 m 5.781 m 6.937 m 8.094 m 9.250 m
Envolvente (Acero laminado)
N- -3.0158 -2.9217 -2.8275 -2.7334 -2.6393 -2.5452 -2.4511 -2.3570 -2.2629
N+ 1.8326 1.8884 1.9441 1.9999 2.0557 2.1114 2.1672 2.2230 2.2787
Ty- -0.2827 -0.2827 -0.2827 -0.2827 -0.2827 -0.2827 -0.2827 -0.2827 -0.2827
Ty+ 0.1874 0.1874 0.1874 0.1874 0.1874 0.1874 0.1874 0.1874 0.1874
Tz- -2.8696 -2.3580 -1.8463 -1.5244 -1.2295 -0.9347 -0.6470 -0.5993 -1.0089
Tz+ 3.0866 2.6132 2.1397 1.6662 1.1927 0.7192 0.9147 1.4263 1.9379
Mt- -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
65/106
Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008
My- -8.0665 -5.4585 -3.1777 -1.3870 -0.8303 -1.9247 -2.4935 -2.4930 -2.5658
My+ 9.0657 5.7814 3.0227 1.6040 2.8631 3.5070 3.5830 3.2462 3.6204
Mz- -1.4223 -1.0954 -0.7686 -0.4445 -0.1321 -0.1520 -0.3686 -0.5852 -0.8019
Mz+ 0.9312 0.7146 0.4979 0.2841 0.0819 0.2120 0.5388 0.8657 1.1925
82/84 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.6600 -0.6498 -0.6395 -0.6292 -0.6190 -0.6087 -0.5984 -0.5882 -0.5828
N+ 1.3574 1.3606 1.3638 1.3670 1.3702 1.3735 1.3767 1.3799 1.3880
Ty- -0.0286 -0.0286 -0.0286 -0.0286 -0.0286 -0.0286 -0.0286 -0.0286 -0.0286
Ty+ 0.0224 0.0224 0.0224 0.0224 0.0224 0.0224 0.0224 0.0224 0.0224
Tz- -0.5063 -0.3858 -0.3051 -0.3078 -0.3232 -0.3949 -0.4810 -0.6525 -0.8867
Tz+ 0.7908 0.5934 0.3960 0.2051 0.1811 0.2716 0.3764 0.4811 0.5859
Mt- -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001
Mt+ 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002
My- -0.5644 -0.4374 -0.3034 -0.2235 -0.2465 -0.1987 -0.1505 -0.3347 -0.5851
My+ 0.4996 0.2528 0.1908 0.1771 0.1344 0.1482 0.3056 0.5345 0.8210
Mz- -0.0553 -0.0419 -0.0284 -0.0150 -0.0025 -0.0076 -0.0181 -0.0287 -0.0392
Mz+ 0.0451 0.0346 0.0240 0.0135 0.0030 0.0120 0.0254 0.0389 0.0523
83/84 0.000 m 1.203 m 2.406 m 3.609 m 4.813 m 6.016 m 7.219 m 8.422 m 9.625 m
Envolvente (Acero laminado)
N- -2.4000 -2.3021 -2.2042 -2.1063 -2.0084 -1.9104 -1.8125 -1.7146 -1.6167
N+ 1.2622 1.3202 1.3782 1.4363 1.4943 1.5523 1.6104 1.6684 1.7264
Ty- -0.2326 -0.2326 -0.2326 -0.2326 -0.2326 -0.2326 -0.2326 -0.2326 -0.2326
Ty+ 0.1606 0.1606 0.1606 0.1606 0.1606 0.1606 0.1606 0.1606 0.1606
Tz- -2.1911 -1.7759 -1.4878 -1.2243 -0.9608 -0.6973 -0.4338 -0.4875 -0.9098
Tz+ 2.6321 2.2098 1.7875 1.3652 0.9429 0.5206 0.6701 1.0924 1.5147
Mt- -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008
Mt+ 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006
My- -6.7598 -4.5006 -2.5458 -0.9958 -0.8752 -1.7454 -2.1279 -1.9819 -1.6009
My+ 7.7271 4.8245 2.4098 1.2933 2.1611 2.5006 2.3524 2.4353 2.4881
Mz- -1.2535 -0.9737 -0.6947 -0.4168 -0.1388 -0.1263 -0.3195 -0.5127 -0.7059
Mz+ 0.8398 0.6466 0.4542 0.2628 0.0715 0.1455 0.4253 0.7051 0.9849
84/86 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -0.7221 -0.7119 -0.7016 -0.6913 -0.6811 -0.6708 -0.6605 -0.6503 -0.6437
N+ 1.4849 1.4881 1.4913 1.4945 1.4977 1.5009 1.5041 1.5073 1.5143
Ty- -0.0345 -0.0345 -0.0345 -0.0345 -0.0345 -0.0345 -0.0345 -0.0345 -0.0345
Ty+ 0.0442 0.0442 0.0442 0.0442 0.0442 0.0442 0.0442 0.0442 0.0442
Tz- -0.4969 -0.3764 -0.2559 -0.2024 -0.3420 -0.5675 -0.8017 -1.0630 -1.3696
Tz+ 0.6036 0.3694 0.2212 0.1833 0.2149 0.3109 0.4157 0.5204 0.6252
Mt- -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003
Mt+ 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004
My- -0.3489 -0.3122 -0.3141 -0.3341 -0.3127 -0.1715 -0.2235 -0.4009 -0.6698
My+ 0.3389 0.2422 0.2090 0.1867 0.1746 0.2308 0.4862 0.8772 1.4181
Mz- -0.0614 -0.0453 -0.0295 -0.0141 -0.0024 -0.0232 -0.0440 -0.0649 -0.0857
Mz+ 0.0808 0.0601 0.0394 0.0187 0.0036 0.0199 0.0361 0.0524 0.0686
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
66/106
85/86 0.000 m 1.250 m 2.500 m 3.750 m 5.000 m 6.250 m 7.500 m 8.750 m 10.000 m
Envolvente (Acero laminado)
N- -1.7057 -1.5617 -1.4178 -1.2739 -1.1300 -0.9861 -0.8421 -0.6982 -0.5543
N+ 1.0531 1.1384 1.2237 1.3090 1.3943 1.4796 1.5648 1.6501 1.7354
Ty- -1.1870 -0.9676 -0.7483 -0.5289 -0.3095 -0.2057 -0.5338 -0.8619 -1.1900
Ty+ 1.4606 1.1325 0.8043 0.4762 0.2934 0.1565 0.1310 0.3504 0.5697
Tz- -1.7437 -1.4677 -1.1916 -0.9156 -0.6395 -0.3902 -0.7343 -1.2002 -1.6660
Tz+ 2.0836 1.6178 1.1519 0.6861 0.3517 0.2266 0.1016 0.2140 0.4901
Mt- -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006
Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008
My- -5.2806 -3.2804 -1.6114 -1.7088 -2.2866 -2.2591 -1.6725 -0.7755 -0.6710
My+ 3.4731 1.8625 1.0288 0.3632 0.6827 1.2996 1.5861 1.5159 1.4188
Mz- -2.9778 -1.6368 -0.5590 -0.8810 -1.2496 -1.2147 -0.8507 -0.7862 -0.5575
Mz+ 2.7787 1.4141 0.6164 0.2354 0.7635 1.0078 0.9888 0.6847 1.4228 6.- Tensiones
Barras TENSIÓN MÁXIMA
TENS. () APROV. (%) Pos. (m) N (t) Ty (t) Tz (t) Mt (t�m) My (t�m) Mz (t�m)
75/76 0.7814 78.14 0.000 -0.0454 -0.9500 -1.8566 -0.0003 -3.3662 -1.9174
76/78 0.7635 76.35 0.000 -0.1712 -0.0283 -0.4409 0.0000 -1.0379 -0.0560
77/78 0.6399 63.99 0.000 1.5559 -0.1057 2.4848 0.0000 6.8733 -0.4889
78/80 0.5601 56.01 3.769 -0.1924 0.0184 0.6705 -0.0002 -0.7663 -0.0356
79/80 0.7823 78.23 0.000 1.9472 -0.0564 3.0223 -0.0002 8.6649 -0.3408
80/82 0.7042 70.42 5.025 -0.0429 0.0105 0.6877 0.0000 -0.7570 -0.0261
81/82 0.8677 86.77 0.000 1.8326 -0.1026 3.0866 -0.0005 9.0657 -0.4718
82/84 0.4471 44.71 0.000 -0.6600 -0.0275 -0.2616 0.0000 -0.5644 -0.0531
83/84 0.7622 76.22 0.000 1.2622 -0.0837 2.6321 -0.0007 7.7271 -0.4106
84/86 0.5465 54.65 3.769 1.5105 -0.0325 -1.2701 0.0003 1.4181 0.0625
85/86 0.9403 94.03 0.000 0.4195 1.4605 -1.7365 0.0008 -5.2550 2.7787
Resultados de cálculo en pórtico intermedio 1.- Barras: Descripción
Barras Material Perfil Peso Volumen Longitud Co.pand.xy Co.pand.xz Dist.arr.sup. Dist.arr.inf.
(kp) (m³) (m) (m) (m)
67/68 Acero (S275) HE 260 A (HEA) 545.10 0.069 8.00 0.70 1.33 8.00 8.00
68/69 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77
69/70 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77
70/71 Acero (S275) IPE 450 (IPE) 389.72 0.050 5.02 0.05 0.73 1.00 5.02
71/72 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77
72/74 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77
73/74 Acero (S275) HE 300 A (HEA) 883.12 0.112 10.00 0.70 1.22 10.00 10.00
2.- Cargas (Barras)
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
67/106
Barras Hipót. Tipo Cargas Dirección
P1 P2 L1 (m) L2 (m) X Y Z
67/68 1 (PP 1) Uniforme 0.068 t/m - - - 0.000 0.000 -1.000
67/68 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000
67/68 3 (V 1) Uniforme 0.294 t/m - - - 0.000 1.000 0.000
67/68 4 (V 2) Uniforme 0.294 t/m - - - 0.000 1.000 0.000
67/68 5 (V 3) Uniforme 0.207 t/m - - - 0.000 -1.000 0.000
67/68 6 (V 4) Uniforme 0.133 t/m - - - 0.000 -1.000 0.000
67/68 7 (V 5) Uniforme 0.133 t/m - - - 0.000 -1.000 0.000
67/68 8 (V 6) Uniforme 0.149 t/m - - - 0.000 -1.000 0.000
67/68 8 (V 6) Uniforme 0.232 t/m - - - 0.000 -1.000 0.000
68/69 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000
68/69 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000
68/69 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000
68/69 3 (V 1) Trapez. 0.583 t/m 0.583 t/m 0.000 2.010 0.000 -0.100 0.995
68/69 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 2.010 3.769 0.000 -0.100 0.995
68/69 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 2.010 0.000 0.100 -0.995
68/69 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 2.010 3.769 0.000 0.100 -0.995
68/69 5 (V 3) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995
68/69 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995
68/69 7 (V 5) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995
68/69 8 (V 6) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995
68/69 9 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
68/69 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
68/69 11 (N 3) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
69/70 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000
69/70 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000
69/70 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000
69/70 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 0.000 3.769 0.000 -0.100 0.995
69/70 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 3.769 0.000 0.100 -0.995
69/70 5 (V 3) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995
69/70 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995
69/70 7 (V 5) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995
69/70 8 (V 6) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995
69/70 9 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
69/70 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
69/70 11 (N 3) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
70/71 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000
70/71 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000
70/71 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000
70/71 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 0.000 5.025 0.000 -0.100 0.995
70/71 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 5.025 0.000 0.100 -0.995
70/71 5 (V 3) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995
70/71 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 5.025 0.000 -0.100 0.995
70/71 7 (V 5) Trapez. 0.334 t/m 0.334 t/m 0.000 5.025 0.000 -0.100 0.995
70/71 8 (V 6) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995
70/71 9 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
68/106
70/71 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
70/71 11 (N 3) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
71/72 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000
71/72 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000
71/72 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000
71/72 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 0.000 3.769 0.000 -0.100 0.995
71/72 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 3.769 0.000 0.100 -0.995
71/72 5 (V 3) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995
71/72 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995
71/72 7 (V 5) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995
71/72 8 (V 6) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995
71/72 9 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
71/72 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
71/72 11 (N 3) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
72/74 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000
72/74 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000
72/74 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000
72/74 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 0.000 3.769 0.000 -0.100 0.995
72/74 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 3.769 0.000 0.100 -0.995
72/74 5 (V 3) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995
72/74 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 1.759 0.000 -0.100 0.995
72/74 6 (V 4) Trapez. 0.748 t/m 0.748 t/m 1.759 3.769 0.000 -0.100 0.995
72/74 7 (V 5) Trapez. 0.334 t/m 0.334 t/m 0.000 1.759 0.000 -0.100 0.995
72/74 7 (V 5) Trapez. 0.748 t/m 0.748 t/m 1.759 3.769 0.000 -0.100 0.995
72/74 8 (V 6) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995
72/74 9 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
72/74 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000
72/74 11 (N 3) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000
73/74 1 (PP 1) Uniforme 0.088 t/m - - - 0.000 0.000 -1.000
73/74 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000
73/74 3 (V 1) Faja 0.133 t/m - 0.000 10.000 0.000 1.000 0.000
73/74 4 (V 2) Faja 0.133 t/m - 0.000 10.000 0.000 1.000 0.000
73/74 5 (V 3) Faja 0.207 t/m - 0.000 10.000 0.000 1.000 0.000
73/74 6 (V 4) Faja 0.294 t/m - 0.000 10.000 0.000 -1.000 0.000
73/74 7 (V 5) Faja 0.294 t/m - 0.000 10.000 0.000 -1.000 0.000
73/74 8 (V 6) Faja 0.381 t/m - 0.000 10.000 0.000 1.000 0.000 3.- Desplazamientos
Nudos Descripción DESPLAZAMIENTOS (EJES GENERALES)
DX (m) DY (m) DZ (m) GX (rad) GY (rad) GZ (rad)
67 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
68 Envolvente (Desplazam.) -0.0167 -0.0350 -0.0002 -0.0068 -0.0007 -0.0026
0.0164 0.0233 0.0000 0.0026 0.0006 0.0025
69 Envolvente (Desplazam.) -0.0291 -0.0357 -0.0266 -0.0064 -0.0048 -0.0032
0.0289 0.0259 0.0066 0.0010 0.0016 0.0028
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
69/106
70 Envolvente (Desplazam.) -0.0393 -0.0358 -0.0443 -0.0028 -0.0081 -0.0023
0.0391 0.0277 0.0079 -0.0001 0.0022 0.0017
71 Envolvente (Desplazam.) -0.0440 -0.0355 -0.0416 -0.0010 -0.0079 -0.0009
0.0437 0.0274 0.0045 0.0036 0.0017 0.0002
72 Envolvente (Desplazam.) -0.0384 -0.0351 -0.0222 -0.0007 -0.0044 -0.0025
0.0382 0.0254 0.0009 0.0062 0.0008 0.0020
73 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
74 Envolvente (Desplazam.) -0.0278 -0.0351 -0.0002 -0.0002 -0.0011 -0.0025
0.0279 0.0232 0.0000 0.0049 0.0011 0.0024 4.- Reacciones
Nudos Descripción REACCIONES (EJES GENERALES)
RX (t) RY (t) RZ (t) MX (t�m) MY (t�m) MZ (t�m)
67 Envolvente (Cim.equil.) -0.4008 -3.2129 -0.4119 -11.2431 -1.7001 -0.0021
0.4009 3.5685 6.6018 7.6488 1.7083 0.0022
67 Envolvente (Cim.tens.terr.) -0.2505 -1.7928 0.8153 -7.6441 -1.0623 -0.0013
0.2506 2.4661 4.6398 4.2171 1.0679 0.0014
73 Envolvente (Cim.equil.) -0.5729 -3.9016 -1.6049 -16.8960 -3.0898 -0.0026
0.5617 4.9935 7.7533 13.7137 3.0471 0.0028
73 Envolvente (Cim.tens.terr.) -0.3579 -2.6737 0.2263 -9.8550 -1.9299 -0.0016
0.3511 2.9062 5.6115 9.3435 1.9048 0.0017 5.- Esfuerzos
Barras Esf. ESFUERZOS (EJES LOCALES) (t)(t�m)
0 L 1/8 L 1/4 L 3/8 L 1/2 L 5/8 L 3/4 L 7/8 L 1 L
67/68 0.000 m 1.000 m 2.000 m 3.000 m 4.000 m 5.000 m 6.000 m 7.000 m 8.000 m
Envolvente (Acero laminado)
N- -6.0283 -5.8688 -5.7093 -5.5498 -5.3903 -5.2308 -5.0713 -4.9119 -4.7524
N+ 0.7795 0.8740 0.9685 1.0631 1.1576 1.2521 1.3466 1.4411 1.5356
Ty- -0.3758 -0.3758 -0.3758 -0.3758 -0.3758 -0.3758 -0.3758 -0.3758 -0.3758
Ty+ 0.3758 0.3758 0.3758 0.3758 0.3758 0.3758 0.3758 0.3758 0.3758
Tz- -3.3132 -2.8120 -2.6078 -2.4077 -2.2075 -2.0074 -1.8072 -1.6345 -1.6669
Tz+ 3.0910 2.6493 2.2076 1.7659 1.3242 0.8825 0.9010 1.4724 2.0439
Mt- -0.0021 -0.0021 -0.0021 -0.0021 -0.0021 -0.0021 -0.0021 -0.0021 -0.0021
Mt+ 0.0020 0.0020 0.0020 0.0020 0.0020 0.0020 0.0020 0.0020 0.0020
My- -10.4559 -7.5519 -4.8400 -2.6368 -1.4532 -2.5478 -3.2183 -3.4295 -3.2166
My+ 7.3773 4.6563 2.6521 1.5502 2.5879 3.5878 4.7933 6.3579 7.9348
Mz- -1.6014 -1.2256 -0.8500 -0.4745 -0.0993 -0.2848 -0.6606 -1.0364 -1.4122
Mz+ 1.5941 1.2183 0.8426 0.4672 0.0921 0.2776 0.6534 1.0291 1.4049
68/69 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -2.0834 -2.0564 -2.0294 -2.0024 -1.9754 -1.9484 -1.9214 -1.8944 -1.8674
N+ 2.1102 2.1184 2.1265 2.1346 2.1428 2.1509 2.1590 2.1672 2.1753
Ty- -0.2343 -0.2343 -0.2343 -0.2343 -0.2343 -0.2343 -0.2343 -0.2343 -0.2343
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
70/106
Ty+ 0.2587 0.2587 0.2587 0.2587 0.2587 0.2587 0.2587 0.2587 0.2587
Tz- -4.2105 -3.9404 -3.6703 -3.4002 -3.1300 -2.8599 -2.5898 -2.3197 -2.0496
Tz+ 2.0270 1.6966 1.3661 1.1328 1.0637 0.9946 0.9255 0.8564 0.7872
Mt- -0.0092 -0.0092 -0.0092 -0.0092 -0.0092 -0.0092 -0.0092 -0.0092 -0.0092
Mt+ 0.0056 0.0056 0.0056 0.0056 0.0056 0.0056 0.0056 0.0056 0.0056
My- -7.9354 -6.7330 -6.0819 -5.5154 -4.9481 -4.7714 -4.9132 -4.9793 -4.9753
My+ 3.2165 2.3426 1.6181 1.6161 2.0606 2.8529 3.9257 4.8816 5.7296
Mz- -0.4727 -0.3623 -0.2520 -0.1416 -0.0312 -0.0813 -0.2030 -0.3249 -0.4468
Mz+ 0.5283 0.4064 0.2845 0.1626 0.0408 0.0793 0.1895 0.2998 0.4102
69/70 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -1.9026 -1.8756 -1.8486 -1.8216 -1.7946 -1.7675 -1.7405 -1.7135 -1.6865
N+ 2.2018 2.2099 2.2181 2.2262 2.2343 2.2425 2.2506 2.2588 2.2669
Ty- -0.1574 -0.1574 -0.1574 -0.1574 -0.1574 -0.1574 -0.1574 -0.1574 -0.1574
Ty+ 0.1759 0.1759 0.1759 0.1759 0.1759 0.1759 0.1759 0.1759 0.1759
Tz- -2.5468 -2.2766 -2.0065 -1.7364 -1.4663 -1.1962 -0.9261 -0.7757 -0.7642
Tz+ 0.7386 0.6694 0.6003 0.5312 0.4621 0.3930 0.3239 0.2548 0.1856
Mt- -0.0065 -0.0065 -0.0065 -0.0065 -0.0065 -0.0065 -0.0065 -0.0065 -0.0065
Mt+ 0.0032 0.0032 0.0032 0.0032 0.0032 0.0032 0.0032 0.0032 0.0032
My- -4.9755 -5.2581 -5.4707 -5.6073 -5.6740 -5.6648 -5.5857 -5.4306 -5.2056
My+ 5.7292 6.6507 7.4643 8.2978 9.0097 9.5879 10.0429 10.3643 10.5625
Mz- -0.1448 -0.0706 -0.0288 -0.0690 -0.1517 -0.2344 -0.3171 -0.3998 -0.4826
Mz+ 0.1804 0.0975 0.0146 0.0784 0.1524 0.2264 0.3004 0.3744 0.4485
70/71 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m
Envolvente (Acero laminado)
N- -1.7675 -1.7314 -1.6954 -1.6594 -1.6234 -1.5874 -1.5514 -1.5154 -1.4793
N+ 2.3129 2.3238 2.3346 2.3455 2.3563 2.3672 2.3780 2.3889 2.3997
Ty- -0.0497 -0.0497 -0.0497 -0.0497 -0.0497 -0.0497 -0.0497 -0.0497 -0.0497
Ty+ 0.0639 0.0639 0.0639 0.0639 0.0639 0.0639 0.0639 0.0639 0.0639
Tz- -1.3726 -1.0125 -0.6523 -0.4190 -0.4543 -0.6607 -0.8671 -1.0735 -1.2800
Tz+ 0.5346 0.4173 0.3000 0.1868 0.2964 0.6146 0.9370 1.3005 1.6640
Mt- -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009
Mt+ 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009
My- -5.2062 -5.3758 -5.4209 -5.3311 -5.1169 -4.7678 -4.2943 -3.6859 -2.9530
My+ 10.5624 11.2250 11.6685 11.8745 11.8613 11.6107 11.1409 10.4336 9.5072
Mz- -0.0749 -0.1117 -0.1514 -0.1912 -0.2311 -0.2709 -0.3108 -0.3507 -0.3907
Mz+ 0.1070 0.1378 0.1687 0.1995 0.2304 0.2613 0.2921 0.3231 0.3543
71/72 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -1.5475 -1.5205 -1.4935 -1.4665 -1.4395 -1.4125 -1.3855 -1.3584 -1.3314
N+ 2.4763 2.4844 2.4926 2.5007 2.5088 2.5170 2.5251 2.5332 2.5414
Ty- -0.0761 -0.0761 -0.0761 -0.0761 -0.0761 -0.0761 -0.0761 -0.0761 -0.0761
Ty+ 0.0932 0.0932 0.0932 0.0932 0.0932 0.0932 0.0932 0.0932 0.0932
Tz- -0.4873 -0.6421 -0.7969 -0.9517 -1.1066 -1.2614 -1.4162 -1.5710 -1.7258
Tz+ 0.9499 1.1885 1.4271 1.6658 1.9182 2.1908 2.4634 2.7360 3.0086
Mt- -0.0039 -0.0039 -0.0039 -0.0039 -0.0039 -0.0039 -0.0039 -0.0039 -0.0039
Mt+ 0.0069 0.0069 0.0069 0.0069 0.0069 0.0069 0.0069 0.0069 0.0069
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
71/106
My- -2.9536 -2.6861 -2.3486 -1.9988 -1.9316 -1.8423 -1.7131 -1.5409 -1.3289
My+ 9.5077 9.0510 8.5714 7.9876 7.2816 6.4433 5.4829 4.3901 3.3146
Mz- -0.3917 -0.3558 -0.3199 -0.2841 -0.2482 -0.2124 -0.1768 -0.1417 -0.1066
Mz+ 0.4211 0.3772 0.3333 0.2894 0.2455 0.2016 0.1581 0.1149 0.0718
72/74 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m
Envolvente (Acero laminado)
N- -1.3430 -1.3160 -1.2890 -1.2620 -1.2350 -1.2080 -1.1810 -1.1540 -1.1269
N+ 2.6343 2.6425 2.6506 2.6587 2.6669 2.6750 2.6831 2.6913 2.6994
Ty- -0.2179 -0.2179 -0.2179 -0.2179 -0.2179 -0.2179 -0.2179 -0.2179 -0.2179
Ty+ 0.2376 0.2376 0.2376 0.2376 0.2376 0.2376 0.2376 0.2376 0.2376
Tz- -1.2242 -1.3790 -1.5338 -1.6886 -1.9213 -2.3688 -2.8162 -3.2636 -3.7111
Tz+ 2.8045 3.0431 3.2987 3.5713 3.8439 4.1165 4.3891 4.6617 4.9343
Mt- -0.0042 -0.0042 -0.0042 -0.0042 -0.0042 -0.0042 -0.0042 -0.0042 -0.0042
Mt+ 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082
My- -1.3287 -1.3446 -1.9867 -3.1643 -4.8767 -6.7059 -8.6431 -10.6971 -12.8591
My+ 3.3152 2.9833 2.9588 3.2784 4.1112 5.1260 6.3430 7.7793 9.4179
Mz- -0.4402 -0.3376 -0.2350 -0.1323 -0.0297 -0.0912 -0.2031 -0.3151 -0.4270
Mz+ 0.4683 0.3564 0.2445 0.1326 0.0207 0.0730 0.1756 0.2782 0.3809
73/74 0.000 m 1.250 m 2.500 m 3.750 m 5.000 m 6.250 m 7.500 m 8.750 m 10.000 m
Envolvente (Acero laminado)
N- -7.0843 -6.8509 -6.6175 -6.3841 -6.1507 -5.9173 -5.6839 -5.4505 -5.2171
N+ 1.9553 2.0937 2.2320 2.3703 2.5086 2.6469 2.7852 2.9235 3.0618
Ty- -0.5265 -0.5265 -0.5265 -0.5265 -0.5265 -0.5265 -0.5265 -0.5265 -0.5265
Ty+ 0.5372 0.5372 0.5372 0.5372 0.5372 0.5372 0.5372 0.5372 0.5372
Tz- -4.7601 -4.2080 -3.6559 -3.1038 -2.5516 -1.9995 -1.4474 -2.1583 -2.8726
Tz+ 3.6255 3.3115 3.0613 2.8111 2.5609 2.3107 2.0606 1.8104 1.6048
Mt- -0.0026 -0.0026 -0.0026 -0.0026 -0.0026 -0.0026 -0.0026 -0.0026 -0.0026
Mt+ 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025
My- -16.0985 -10.5072 -5.5785 -2.6692 -4.0793 -5.5941 -8.3324 -10.7455 -12.8584
My+ 12.7509 8.4614 4.4722 1.1738 2.1809 5.0115 7.1796 8.6300 9.4178
Mz- -2.8564 -2.1985 -1.5405 -0.8826 -0.2249 -0.4606 -1.1321 -1.8037 -2.4752
Mz+ 2.8971 2.2258 1.5545 0.8833 0.2122 0.4346 1.0927 1.7508 2.4089 6.- Tensiones
Barras TENSIÓN MÁXIMA
TENS. () APROV. (%) Pos. (m) N (t) Ty (t) Tz (t) Mt (t�m) My (t�m) Mz (t�m)
67/68 0.6965 69.65 0.000 -3.0590 0.0008 -3.0080 0.0001 -10.4558 0.0317
68/69 0.2654 26.54 0.000 -1.8084 -0.0361 -2.7131 -0.0037 -7.9309 -0.0766
69/70 0.2441 24.41 3.769 -1.6865 0.0163 -0.2788 -0.0063 10.5625 -0.0389
70/71 0.2683 26.83 2.010 -1.6522 0.0089 -0.0808 0.0007 11.8937 0.0019
71/72 0.2191 21.91 0.000 -1.5474 0.0137 0.8276 0.0069 9.5068 0.0300
72/74 0.4209 42.09 3.769 -1.1101 0.0448 4.7133 0.0064 -12.8588 -0.0945
73/74 0.7485 74.85 0.000 1.9553 0.0712 -4.7601 -0.0002 -16.0985 0.4599
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
72/106
2.2.2 Cimentación
La cimentación se realizará mediante zapatas centradas para todos los
pilares, arriostradas mediante vigas de atado de hormigón armado.
Tanto las zapatas como las vigas de atado se realizarán con hormigón
armado HA-35/B/20/IV-Qc sobre cama de hormigón de limpieza HM-10 de 10
cm de espesor, y armadura de redondos de acero B-400-S.
• Acciones adoptadas en el cálculo
Para los elementos de cimentación de hormigón armado, se han
considerado las siguientes acciones:
Densidad del hormigón armado 2.50 tn/m² (2.30 t/m3 para hormigones en masa y poco armados)
Cargas y sobrecargas: Las consideradas en el CTE DB SE-A
Acciones de la estructura sobre la cimentación.
• Métodos de cálculo e hipótesis de carga
Para el cálculo de los elementos de hormigón se han considerado los
siguientes coeficientes de seguridad, correspondientes a la EHE.
COEFICIENTE DE PONDERACIÓN Y SEGURIDAD
Coeficiente de minoración de resistencia del hormigón γc = 1,50
Coeficiente de minoración de resistencia del acero γs = 1,15
Coeficiente de mayoración de las acciones γf = 1,60
• Resultados obtenidos en el cálculo de la cimentación
Descripción
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
73/106
Referencias Materiales Geometría Armado
Nudo 1 Nudo 75
Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa
Zapata cuadrada Ancho: 215.0 cm Canto: 50.0 cm
Sup X: 10Ø12c/22 Sup Y: 10Ø12c/22 Inf X: 10Ø12c/22 Inf Y: 10Ø12c/22
Nudo 36
Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa
Zapata cuadrada Ancho: 280.0 cm Canto: 65.0 cm
Sup X: 16Ø12c/17 Sup Y: 16Ø12c/17 Inf X: 16Ø12c/17 Inf Y: 16Ø12c/17
Nudo 11 Nudo 16 Nudo 41 Nudo 85
Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa
Zapata cuadrada Ancho: 235.0 cm Canto: 55.0 cm
Sup X: 12Ø12c/20 Sup Y: 12Ø12c/20 Inf X: 12Ø12c/20 Inf Y: 12Ø12c/20
Nudo 18 Nudo 30 Nudo 43 Nudo 51 Nudo 59 Nudo 67
Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa
Zapata rectangular centrada Ancho zapata X: 295.0 cm Ancho zapata Y: 200.0 cm Canto: 70.0 cm
Sup X: 18Ø12c/16 Sup Y: 12Ø12c/16 Inf X: 18Ø12c/16 Inf Y: 12Ø12c/16
Nudo 49 Nudo 57 Nudo 65 Nudo 73
Hormigón: HA-35, Yc=1.5 Acero: B 500 S, Ys=1.15 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa
Zapata rectangular centrada Ancho zapata X: 360.0 cm Ancho zapata Y: 240.0 cm Canto: 85.0 cm
Sup X: 27Ø12c/13 Sup Y: 18Ø12c/13 Inf X: 27Ø12c/13 Inf Y: 18Ø12c/13
Nudo 3 Nudo 5 Nudo 7 Nudo 9 Nudo 77 Nudo 79 Nudo 81 Nudo 83
Hormigón: HA-35, Yc=1.5 Acero: B 500 S, Ys=1.15 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa
Zapata rectangular centrada Ancho zapata X: 295.0 cm Ancho zapata Y: 195.0 cm Canto: 70.0 cm
Sup X: 18Ø12c/16 Sup Y: 12Ø12c/16 Inf X: 18Ø12c/16 Inf Y: 12Ø12c/16
Nudo 14 Nudo 24 Nudo 28 Nudo 39
Hormigón: HA-35, Yc=1.5 Acero: B 500 S, Ys=1.15 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa
Zapata rectangular centrada Ancho zapata X: 275.0 cm Ancho zapata Y: 195.0 cm Canto: 65.0 cm
Sup X: 16Ø12c/17 Sup Y: 11Ø12c/17 Inf X: 16Ø12c/17 Inf Y: 11Ø12c/17
Comprobación
A continuación mostramos las comprobaciones para una zapata de cada
tipo:
• Zapata NUDO 1:
Referencia: 1
Dimensiones: 215 x 215 x 50
Armados: Xi:Ø12c/22 Yi:Ø12c/22 Xs:Ø12c/22 Ys:Ø12c/22
Comprobación Valores Estado
Tensiones sobre el terreno:
Criterio de CYPE Ingenieros
-Tensión media en situaciones persistentes:
Máximo: 2 kp/cm² Calculado: 0.175 kp/cm²
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
74/106
-Tensión máxima en situaciones persistentes sin viento:
Máximo: 2.5 kp/cm² Calculado: 0.158 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes con viento:
Máximo: 2.5 kp/cm² Calculado: 0.435 kp/cm²
Cumple
Vuelco de la zapata:
Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.
-En dirección X:
Reserva seguridad: 153.1 %
Cumple
-En dirección Y:
Reserva seguridad: 69.8 %
Cumple
Flexión en la zapata:
-En dirección X:
Momento: 1.58 t�m
Cumple
-En dirección Y:
Momento: 2.59 t�m
Cumple
Cortante en la zapata:
-En dirección X:
Cortante: 1.80 t
Cumple
-En dirección Y:
Cortante: 3.08 t
Cumple
Compresión oblicua en la zapata:
-Situaciones persistentes:
Criterio de CYPE Ingenieros
Máximo: 509.68 t/m² Calculado: 5.72 t/m²
Cumple
Canto mínimo:
Artículo 59.8.1 (norma EHE-98)
Mínimo: 25 cm Calculado: 50 cm
Cumple
Espacio para anclar arranques en cimentación:
-1:
Mínimo: 0 cm Calculado: 43 cm
Cumple
Cuantía geométrica mínima:
Criterio de CYPE Ingenieros
Mínimo: 0.002
-En dirección X:
Calculado: 0.0021
Cumple
-En dirección Y:
Calculado: 0.0021
Cumple
Cuantía mínima necesaria por flexión:
Artículo 42.3.2 (norma EHE-98)
Calculado: 0.0011
-Armado inferior dirección X:
Mínimo: 0.0002
Cumple
-Armado inferior dirección Y:
Mínimo: 0.0003
Cumple
-Armado superior dirección X:
Mínimo: 0.0002
Cumple
-Armado superior dirección Y:
Mínimo: 0.0002
Cumple
Diámetro mínimo de las barras:
Recomendación del Artículo 59.8.2 (norma EHE-
Mínimo: 12 mm
-Parrilla inferior:
Calculado: 12 mm
Cumple
-Parrilla superior:
Calculado: 12 mm
Cumple
Separación máxima entre barras:
Artículo 59.8.2 (norma EHE-98)
Máximo: 30 cm
-Armado inferior dirección X:
Calculado: 22 cm
Cumple
-Armado inferior dirección Y:
Calculado: 22 cm
Cumple
-Armado superior dirección X:
Calculado: 22 cm
Cumple
-Armado superior dirección Y:
Calculado: 22 cm
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
75/106
Separación mínima entre barras:
Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 10 cm
-Armado inferior dirección X:
Calculado: 22 cm
Cumple
-Armado inferior dirección Y:
Calculado: 22 cm
Cumple
-Armado superior dirección X:
Calculado: 22 cm
Cumple
-Armado superior dirección Y:
Calculado: 22 cm
Cumple
Longitud de anclaje:
Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 15 cm
-Armado inf. dirección X hacia der:
Calculado: 54 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 54 cm
Cumple
-Armado inf. dirección Y hacia arriba:
Calculado: 54 cm
Cumple
-Armado inf. dirección Y hacia abajo:
Calculado: 54 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 54 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 54 cm
Cumple
-Armado sup. dirección Y hacia arriba:
Calculado: 54 cm
Cumple
-Armado sup. dirección Y hacia abajo:
Calculado: 54 cm
Cumple
Se cumplen todas las comprobaciones
Información adicional:
- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))
- Relación rotura pésima (En dirección X): 0.11
- Relación rotura pésima (En dirección Y): 0.18
- Cortante de agotamiento (En dirección X): 27.21 t
- Cortante de agotamiento (En dirección Y): 27.21 t
• Zapata NUDO 41:
Referencia: 41
Dimensiones: 235 x 235 x 55
Armados: Xi:Ø12c/20 Yi:Ø12c/20 Xs:Ø12c/20 Ys:Ø12c/20
Comprobación Valores Estado
Tensiones sobre el terreno:
Criterio de CYPE Ingenieros
-Tensión media en situaciones persistentes:
Máximo: 2 kp/cm² Calculado: 0.171 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes sin viento:
Máximo: 2.5 kp/cm² Calculado: 0.248 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes con viento:
Máximo: 2.5 kp/cm² Calculado: 0.376 kp/cm²
Cumple
Vuelco de la zapata:
Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.
-En dirección X:
Reserva seguridad: 175.9 %
Cumple
-En dirección Y:
Reserva seguridad: 34.7 %
Cumple
Flexión en la zapata:
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
76/106
-En dirección X:
Momento: 1.52 t�m
Cumple
-En dirección Y:
Momento: 3.47 t�m
Cumple
Cortante en la zapata:
-En dirección X:
Cortante: 1.59 t
Cumple
-En dirección Y:
Cortante: 4.01 t
Cumple
Compresión oblicua en la zapata:
-Situaciones persistentes:
Criterio de CYPE Ingenieros
Máximo: 509.68 t/m² Calculado: 6.46 t/m²
Cumple
Canto mínimo:
Artículo 59.8.1 (norma EHE-98)
Mínimo: 25 cm Calculado: 55 cm
Cumple
Espacio para anclar arranques en cimentación:
-41:
Mínimo: 0 cm Calculado: 48 cm
Cumple
Cuantía geométrica mínima:
Criterio de CYPE Ingenieros
Mínimo: 0.002
-En dirección X:
Calculado: 0.0021
Cumple
-En dirección Y:
Calculado: 0.0021
Cumple
Cuantía mínima necesaria por flexión:
Artículo 42.3.2 (norma EHE-98)
Calculado: 0.0011
-Armado inferior dirección X:
Mínimo: 0.0002
Cumple
-Armado inferior dirección Y:
Mínimo: 0.0003
Cumple
-Armado superior dirección X:
Mínimo: 0.0002
Cumple
-Armado superior dirección Y:
Mínimo: 0.0002
Cumple
Diámetro mínimo de las barras:
Recomendación del Artículo 59.8.2 (norma EHE-
Mínimo: 12 mm
-Parrilla inferior:
Calculado: 12 mm
Cumple
-Parrilla superior:
Calculado: 12 mm
Cumple
Separación máxima entre barras:
Artículo 59.8.2 (norma EHE-98)
Máximo: 30 cm
-Armado inferior dirección X:
Calculado: 20 cm
Cumple
-Armado inferior dirección Y:
Calculado: 20 cm
Cumple
-Armado superior dirección X:
Calculado: 20 cm
Cumple
-Armado superior dirección Y:
Calculado: 20 cm
Cumple
Separación mínima entre barras:
Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 10 cm
-Armado inferior dirección X:
Calculado: 20 cm
Cumple
-Armado inferior dirección Y:
Calculado: 20 cm
Cumple
-Armado superior dirección X:
Calculado: 20 cm
Cumple
-Armado superior dirección Y:
Calculado: 20 cm
Cumple
Longitud de anclaje:
Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 15 cm
-Armado inf. dirección X hacia der:
Calculado: 60 cm
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
77/106
-Armado inf. dirección X hacia izq:
Calculado: 60 cm
Cumple
-Armado inf. dirección Y hacia arriba:
Calculado: 60 cm
Cumple
-Armado inf. dirección Y hacia abajo:
Calculado: 60 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 60 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 60 cm
Cumple
-Armado sup. dirección Y hacia arriba:
Calculado: 60 cm
Cumple
-Armado sup. dirección Y hacia abajo:
Calculado: 60 cm
Cumple
Se cumplen todas las comprobaciones
Información adicional:
- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))
- Relación rotura pésima (En dirección X): 0.08
- Relación rotura pésima (En dirección Y): 0.18
- Cortante de agotamiento (En dirección X): 32.33 t
- Cortante de agotamiento (En dirección Y): 32.33 t
• Zapata NUDO 36:
Referencia: 36
Dimensiones: 280 x 280 x 65
Armados: Xi:Ø12c/17 Yi:Ø12c/17 Xs:Ø12c/17 Ys:Ø12c/17
Comprobación Valores Estado
Tensiones sobre el terreno:
Criterio de CYPE Ingenieros
-Tensión media en situaciones persistentes:
Máximo: 2 kp/cm² Calculado: 0.286 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes sin viento:
Máximo: 2.5 kp/cm² Calculado: 0.462 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes con viento:
Máximo: 2.5 kp/cm² Calculado: 0.605 kp/cm²
Cumple
Vuelco de la zapata:
Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.
-En dirección X:
Reserva seguridad: 165.1 %
Cumple
-En dirección Y:
Reserva seguridad: 20.1 %
Cumple
Flexión en la zapata:
-En dirección X:
Momento: 4.60 t�m
Cumple
-En dirección Y:
Momento: 10.14 t�m
Cumple
Cortante en la zapata:
-En dirección X:
Cortante: 3.86 t
Cumple
-En dirección Y:
Cortante: 8.56 t
Cumple
Compresión oblicua en la zapata:
-Situaciones persistentes:
Criterio de CYPE Ingenieros
Máximo: 509.68 t/m² Calculado: 20.09 t/m²
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
78/106
Canto mínimo:
Artículo 59.8.1 (norma EHE-98)
Mínimo: 25 cm Calculado: 65 cm
Cumple
Espacio para anclar arranques en cimentación:
-36:
Mínimo: 0 cm Calculado: 58 cm
Cumple
Cuantía geométrica mínima:
Criterio de CYPE Ingenieros
Mínimo: 0.002
-En dirección X:
Calculado: 0.0021
Cumple
-En dirección Y:
Calculado: 0.0021
Cumple
Cuantía mínima necesaria por flexión:
Artículo 42.3.2 (norma EHE-98)
Calculado: 0.0011
-Armado inferior dirección X:
Mínimo: 0.0003
Cumple
-Armado inferior dirección Y:
Mínimo: 0.0005
Cumple
-Armado superior dirección X:
Mínimo: 0.0002
Cumple
-Armado superior dirección Y:
Mínimo: 0.0003
Cumple
Diámetro mínimo de las barras:
Recomendación del Artículo 59.8.2 (norma EHE-
Mínimo: 12 mm
-Parrilla inferior:
Calculado: 12 mm
Cumple
-Parrilla superior:
Calculado: 12 mm
Cumple
Separación máxima entre barras:
Artículo 59.8.2 (norma EHE-98)
Máximo: 30 cm
-Armado inferior dirección X:
Calculado: 17 cm
Cumple
-Armado inferior dirección Y:
Calculado: 17 cm
Cumple
-Armado superior dirección X:
Calculado: 17 cm
Cumple
-Armado superior dirección Y:
Calculado: 17 cm
Cumple
Separación mínima entre barras:
Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 10 cm
-Armado inferior dirección X:
Calculado: 17 cm
Cumple
-Armado inferior dirección Y:
Calculado: 17 cm
Cumple
-Armado superior dirección X:
Calculado: 17 cm
Cumple
-Armado superior dirección Y:
Calculado: 17 cm
Cumple
Longitud de anclaje:
Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 15 cm
-Armado inf. dirección X hacia der:
Calculado: 71 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 71 cm
Cumple
-Armado inf. dirección Y hacia arriba:
Calculado: 72 cm
Cumple
-Armado inf. dirección Y hacia abajo:
Calculado: 72 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 71 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 71 cm
Cumple
-Armado sup. dirección Y hacia arriba:
Calculado: 72 cm
Cumple
-Armado sup. dirección Y hacia abajo:
Calculado: 72 cm
Cumple
Se cumplen todas las comprobaciones
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
79/106
Información adicional:
- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))
- Relación rotura pésima (En dirección X): 0.14
- Relación rotura pésima (En dirección Y): 0.31
- Cortante de agotamiento (En dirección X): 44.55 t
- Cortante de agotamiento (En dirección Y): 44.55 t
• Zapata NUDO 18:
Referencia: 18
Dimensiones: 200 x 295 x 70
Armados: Xi:Ø12c/16 Yi:Ø12c/16 Xs:Ø12c/16 Ys:Ø12c/16
Comprobación Valores Estado
Tensiones sobre el terreno:
Criterio de CYPE Ingenieros
-Tensión media en situaciones persistentes:
Máximo: 2 kp/cm² Calculado: 0.273 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes sin viento:
Máximo: 2.5 kp/cm² Calculado: 0.434 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes con viento:
Máximo: 2.5 kp/cm² Calculado: 0.559 kp/cm²
Cumple
Vuelco de la zapata:
Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.
-En dirección X:
Reserva seguridad: 409.0 %
Cumple
-En dirección Y:
Reserva seguridad: 68.6 %
Cumple
Flexión en la zapata:
-En dirección X:
Momento: 1.89 t�m
Cumple
-En dirección Y:
Momento: 6.93 t�m
Cumple
Cortante en la zapata:
-En dirección X:
Cortante: 1.15 t
Cumple
-En dirección Y:
Cortante: 5.50 t
Cumple
Compresión oblicua en la zapata:
-Situaciones persistentes:
Criterio de CYPE Ingenieros
Máximo: 509.68 t/m² Calculado: 15.4 t/m²
Cumple
Canto mínimo:
Artículo 59.8.1 (norma EHE-98)
Mínimo: 25 cm Calculado: 70 cm
Cumple
Espacio para anclar arranques en cimentación:
-18:
Mínimo: 0 cm Calculado: 63 cm
Cumple
Cuantía geométrica mínima:
Criterio de CYPE Ingenieros
Mínimo: 0.002
-En dirección X:
Calculado: 0.0021
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
80/106
-En dirección Y:
Calculado: 0.0021
Cumple
Cuantía mínima necesaria por flexión:
Artículo 42.3.2 (norma EHE-98)
Calculado: 0.0011
-Armado inferior dirección X:
Mínimo: 0.0001
Cumple
-Armado inferior dirección Y:
Mínimo: 0.0004
Cumple
-Armado superior dirección X:
Mínimo: 0.0001
Cumple
-Armado superior dirección Y:
Mínimo: 0.0002
Cumple
Diámetro mínimo de las barras:
Recomendación del Artículo 59.8.2 (norma EHE-
Mínimo: 12 mm
-Parrilla inferior:
Calculado: 12 mm
Cumple
-Parrilla superior:
Calculado: 12 mm
Cumple
Separación máxima entre barras:
Artículo 59.8.2 (norma EHE-98)
Máximo: 30 cm
-Armado inferior dirección X:
Calculado: 16 cm
Cumple
-Armado inferior dirección Y:
Calculado: 16 cm
Cumple
-Armado superior dirección X:
Calculado: 16 cm
Cumple
-Armado superior dirección Y:
Calculado: 16 cm
Cumple
Separación mínima entre barras:
Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 10 cm
-Armado inferior dirección X:
Calculado: 16 cm
Cumple
-Armado inferior dirección Y:
Calculado: 16 cm
Cumple
-Armado superior dirección X:
Calculado: 16 cm
Cumple
-Armado superior dirección Y:
Calculado: 16 cm
Cumple
Longitud de anclaje:
Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 15 cm
-Armado inf. dirección X hacia der:
Calculado: 29 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 29 cm
Cumple
-Armado inf. dirección Y hacia arriba:
Calculado: 77 cm
Cumple
-Armado inf. dirección Y hacia abajo:
Calculado: 77 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 29 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 29 cm
Cumple
-Armado sup. dirección Y hacia arriba:
Calculado: 77 cm
Cumple
-Armado sup. dirección Y hacia abajo:
Calculado: 77 cm
Cumple
Se cumplen todas las comprobaciones
Información adicional:
- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))
- Relación rotura pésima (En dirección X): 0.05
- Relación rotura pésima (En dirección Y): 0.26
- Cortante de agotamiento (En dirección X): 49.86 t
- Cortante de agotamiento (En dirección Y): 33.62 t
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
81/106
• Zapata NUDO 49:
Referencia: 49
Dimensiones: 240 x 360 x 85
Armados: Xi:Ø12c/13 Yi:Ø12c/13 Xs:Ø12c/13 Ys:Ø12c/13
Comprobación Valores Estado
Tensiones sobre el terreno:
Criterio de CYPE Ingenieros
-Tensión media en situaciones persistentes:
Máximo: 2 kp/cm² Calculado: 0.31 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes sin viento:
Máximo: 2.5 kp/cm² Calculado: 0.49 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes con viento:
Máximo: 2.5 kp/cm² Calculado: 0.621 kp/cm²
Cumple
Vuelco de la zapata:
Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.
-En dirección X:
Reserva seguridad: 522.9 %
Cumple
-En dirección Y:
Reserva seguridad: 23.6 %
Cumple
Flexión en la zapata:
-En dirección X:
Momento: 3.49 t�m
Cumple
-En dirección Y:
Momento: 14.50 t�m
Cumple
Cortante en la zapata:
-En dirección X:
Cortante: 1.65 t
Cumple
-En dirección Y:
Cortante: 10.78 t
Cumple
Compresión oblicua en la zapata:
-Situaciones persistentes:
Criterio de CYPE Ingenieros
Máximo: 509.68 t/m² Calculado: 15.26 t/m²
Cumple
Canto mínimo:
Artículo 59.8.1 (norma EHE-98)
Mínimo: 25 cm Calculado: 85 cm
Cumple
Espacio para anclar arranques en cimentación:
-49:
Mínimo: 0 cm Calculado: 78 cm
Cumple
Cuantía geométrica mínima:
Criterio de CYPE Ingenieros
Mínimo: 0.002
-En dirección X:
Calculado: 0.0021
Cumple
-En dirección Y:
Calculado: 0.0021
Cumple
Cuantía mínima necesaria por flexión:
Artículo 42.3.2 (norma EHE-98)
Calculado: 0.0011
-Armado inferior dirección X:
Mínimo: 0.0001
Cumple
-Armado inferior dirección Y:
Mínimo: 0.0005
Cumple
-Armado superior dirección X:
Mínimo: 0.0001
Cumple
-Armado superior dirección Y:
Mínimo: 0.0003
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
82/106
Diámetro mínimo de las barras:
Recomendación del Artículo 59.8.2 (norma EHE-
Mínimo: 12 mm
-Parrilla inferior:
Calculado: 12 mm
Cumple
-Parrilla superior:
Calculado: 12 mm
Cumple
Separación máxima entre barras:
Artículo 59.8.2 (norma EHE-98)
Máximo: 30 cm
-Armado inferior dirección X:
Calculado: 13 cm
Cumple
-Armado inferior dirección Y:
Calculado: 13 cm
Cumple
-Armado superior dirección X:
Calculado: 13 cm
Cumple
-Armado superior dirección Y:
Calculado: 13 cm
Cumple
Separación mínima entre barras:
Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 10 cm
-Armado inferior dirección X:
Calculado: 13 cm
Cumple
-Armado inferior dirección Y:
Calculado: 13 cm
Cumple
-Armado superior dirección X:
Calculado: 13 cm
Cumple
-Armado superior dirección Y:
Calculado: 13 cm
Cumple
Longitud de anclaje:
Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 15 cm
-Armado inf. dirección X hacia der:
Calculado: 35 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 35 cm
Cumple
-Armado inf. dirección Y hacia arriba:
Calculado: 96 cm
Cumple
-Armado inf. dirección Y hacia abajo:
Calculado: 96 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 35 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 35 cm
Cumple
-Armado sup. dirección Y hacia arriba:
Calculado: 96 cm
Cumple
-Armado sup. dirección Y hacia abajo:
Calculado: 96 cm
Cumple
Se cumplen todas las comprobaciones
Información adicional:
- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))
- Relación rotura pésima (En dirección X): 0.05
- Relación rotura pésima (En dirección Y): 0.30
- Cortante de agotamiento (En dirección X): 72.52 t
- Cortante de agotamiento (En dirección Y): 48.12 t
• Zapata NUDO 7:
Referencia: 7
Dimensiones: 195 x 295 x 70
Armados: Xi:Ø12c/16 Yi:Ø12c/16 Xs:Ø12c/16 Ys:Ø12c/16
Comprobación Valores Estado
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
83/106
Tensiones sobre el terreno:
Criterio de CYPE Ingenieros
-Tensión media en situaciones persistentes:
Máximo: 2 kp/cm² Calculado: 0.24 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes sin viento:
Máximo: 2.5 kp/cm² Calculado: 0.303 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes con viento:
Máximo: 2.5 kp/cm² Calculado: 0.481 kp/cm²
Cumple
Vuelco de la zapata:
Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.
-En dirección X:
Reserva seguridad: 705.2 %
Cumple
-En dirección Y:
Reserva seguridad: 3.3 %
Cumple
Flexión en la zapata:
-En dirección X:
Momento: 1.11 t�m
Cumple
-En dirección Y:
Momento: 7.88 t�m
Cumple
Cortante en la zapata:
-En dirección X:
Cortante: 0.65 t
Cumple
-En dirección Y:
Cortante: 6.65 t
Cumple
Compresión oblicua en la zapata:
-Situaciones persistentes:
Criterio de CYPE Ingenieros
Máximo: 509.68 t/m² Calculado: 8.33 t/m²
Cumple
Canto mínimo:
Artículo 59.8.1 (norma EHE-98)
Mínimo: 25 cm Calculado: 70 cm
Cumple
Espacio para anclar arranques en cimentación:
-7:
Mínimo: 0 cm Calculado: 63 cm
Cumple
Cuantía geométrica mínima:
Criterio de CYPE Ingenieros
Mínimo: 0.002
-En dirección X:
Calculado: 0.0021
Cumple
-En dirección Y:
Calculado: 0.0021
Cumple
Cuantía mínima necesaria por flexión:
Artículo 42.3.2 (norma EHE-98)
Calculado: 0.0011
-Armado inferior dirección X:
Mínimo: 0.0001
Cumple
-Armado inferior dirección Y:
Mínimo: 0.0005
Cumple
-Armado superior dirección X:
Mínimo: 0.0001
Cumple
-Armado superior dirección Y:
Mínimo: 0.0003
Cumple
Diámetro mínimo de las barras:
Recomendación del Artículo 59.8.2 (norma EHE-98)
Mínimo: 12 mm
-Parrilla inferior:
Calculado: 12 mm
Cumple
-Parrilla superior:
Calculado: 12 mm
Cumple
Separación máxima entre barras:
Artículo 59.8.2 (norma EHE-98)
Máximo: 30 cm
-Armado inferior dirección X:
Calculado: 16 cm
Cumple
-Armado inferior dirección Y:
Calculado: 16 cm
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
84/106
-Armado superior dirección X:
Calculado: 16 cm
Cumple
-Armado superior dirección Y:
Calculado: 16 cm
Cumple
Separación mínima entre barras:
Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 10 cm
-Armado inferior dirección X:
Calculado: 16 cm
Cumple
-Armado inferior dirección Y:
Calculado: 16 cm
Cumple
-Armado superior dirección X:
Calculado: 16 cm
Cumple
-Armado superior dirección Y:
Calculado: 16 cm
Cumple
Longitud de anclaje:
Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 15 cm
-Armado inf. dirección X hacia der:
Calculado: 27 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 27 cm
Cumple
-Armado inf. dirección Y hacia arriba:
Calculado: 77 cm
Cumple
-Armado inf. dirección Y hacia abajo:
Calculado: 77 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 27 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 27 cm
Cumple
-Armado sup. dirección Y hacia arriba:
Calculado: 77 cm
Cumple
-Armado sup. dirección Y hacia abajo:
Calculado: 77 cm
Cumple
Se cumplen todas las comprobaciones
Información adicional:
- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))
- Relación rotura pésima (En dirección X): 0.03
- Relación rotura pésima (En dirección Y): 0.31
- Cortante de agotamiento (En dirección X): 49.86 t
- Cortante de agotamiento (En dirección Y): 32.76 t
• Zapata NUDO 14:
Referencia: 14
Dimensiones: 195 x 275 x 65
Armados: Xi:Ø12c/17 Yi:Ø12c/17 Xs:Ø12c/17 Ys:Ø12c/17
Comprobación Valores Estado
Tensiones sobre el terreno:
Criterio de CYPE Ingenieros
-Tensión media en situaciones persistentes:
Máximo: 2 kp/cm² Calculado: 0.208 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes sin viento:
Máximo: 2.5 kp/cm² Calculado: 0.21 kp/cm²
Cumple
-Tensión máxima en situaciones persistentes con viento:
Máximo: 2.5 kp/cm² Calculado: 0.427 kp/cm²
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
85/106
Vuelco de la zapata:
Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.
-En dirección X:
Reserva seguridad: 623.1 %
Cumple
-En dirección Y:
Reserva seguridad: 1.9 %
Cumple
Flexión en la zapata:
-En dirección X:
Momento: 1.05 t�m
Cumple
-En dirección Y:
Momento: 6.04 t�m
Cumple
Cortante en la zapata:
-En dirección X:
Cortante: 0.82 t
Cumple
-En dirección Y:
Cortante: 5.69 t
Cumple
Compresión oblicua en la zapata:
-Situaciones persistentes:
Criterio de CYPE Ingenieros
Máximo: 509.68 t/m² Calculado: 6.86 t/m²
Cumple
Canto mínimo:
Artículo 59.8.1 (norma EHE-98)
Mínimo: 25 cm Calculado: 65 cm
Cumple
Espacio para anclar arranques en cimentación:
-14:
Mínimo: 0 cm Calculado: 58 cm
Cumple
Cuantía geométrica mínima:
Criterio de CYPE Ingenieros
Mínimo: 0.002
-En dirección X:
Calculado: 0.0021
Cumple
-En dirección Y:
Calculado: 0.0021
Cumple
Cuantía mínima necesaria por flexión:
Artículo 42.3.2 (norma EHE-98)
Calculado: 0.0011
-Armado inferior dirección X:
Mínimo: 0.0001
Cumple
-Armado inferior dirección Y:
Mínimo: 0.0004
Cumple
-Armado superior dirección X:
Mínimo: 0.0001
Cumple
-Armado superior dirección Y:
Mínimo: 0.0003
Cumple
Diámetro mínimo de las barras:
Recomendación del Artículo 59.8.2 (norma EHE-
Mínimo: 12 mm
-Parrilla inferior:
Calculado: 12 mm
Cumple
-Parrilla superior:
Calculado: 12 mm
Cumple
Separación máxima entre barras:
Artículo 59.8.2 (norma EHE-98)
Máximo: 30 cm
-Armado inferior dirección X:
Calculado: 17 cm
Cumple
-Armado inferior dirección Y:
Calculado: 17 cm
Cumple
-Armado superior dirección X:
Calculado: 17 cm
Cumple
-Armado superior dirección Y:
Calculado: 17 cm
Cumple
Separación mínima entre barras:
Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 10 cm
-Armado inferior dirección X:
Calculado: 17 cm
Cumple
-Armado inferior dirección Y:
Calculado: 17 cm
Cumple
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
86/106
-Armado superior dirección X:
Calculado: 17 cm
Cumple
-Armado superior dirección Y:
Calculado: 17 cm
Cumple
Longitud de anclaje:
Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991
Mínimo: 15 cm
-Armado inf. dirección X hacia der:
Calculado: 32 cm
Cumple
-Armado inf. dirección X hacia izq:
Calculado: 32 cm
Cumple
-Armado inf. dirección Y hacia arriba:
Calculado: 72 cm
Cumple
-Armado inf. dirección Y hacia abajo:
Calculado: 72 cm
Cumple
-Armado sup. dirección X hacia der:
Calculado: 32 cm
Cumple
-Armado sup. dirección X hacia izq:
Calculado: 32 cm
Cumple
-Armado sup. dirección Y hacia arriba:
Calculado: 72 cm
Cumple
-Armado sup. dirección Y hacia abajo:
Calculado: 72 cm
Cumple
Se cumplen todas las comprobaciones
Información adicional:
- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))
- Relación rotura pésima (En dirección X): 0.04
- Relación rotura pésima (En dirección Y): 0.27
- Cortante de agotamiento (En dirección X): 43.75 t
- Cortante de agotamiento (En dirección Y): 30.86 t
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
87/106
( )
=
∑=
221
mMj
om
McalA
RCqG
Qs
n
i
aiii
3.1 Caracterización
3.1.1 Configuración
De acuerdo con el Real Decreto 2267/2004, de 3 de Diciembre, que
aprueba el Reglamento de Seguridad contra incendios en establecimientos
industriales, el establecimiento es del tipo E.
3.1.2 Carga de fuego de las áreas de incendio
Para el cálculo del nivel de riesgo intrínseco del establecimiento
procederemos al cálculo de la densidad de carga al fuego del establecimiento
mediante la metodología dada por el anteriormente citado R.D. 2267/2004:
Calculamos en primer lugar la densidad de carga de fuego de cada uno de
los sectores de incendio en los que está dividida la instalación, y que en este
caso coincidirán con cada una de los distintos edificios de los que está
compuesta:
donde:
QS = densidad de carga de fuego, ponderada y corregida, del sector o área de
incendio, en MJ/m2 o Mcal/m2.
3
3 Cálculo del sistema contra incendios
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
88/106
( )
=
∑=
221
mMj
om
McalA
RCSq
Qs
n
i
aiisi
Gi = masa, en kg, de cada uno de los combustibles (i) que existen en el sector
o área de incendio (incluidos los materiales constructivos combustibles).
qi = poder calorífico, en MJ/kg o Mcal/kg, de cada uno de los combustibles (i)
que existen en el sector de incendio.
n= número de combustibles diferentes que existen en el sector de incendios.
Ci = coeficiente adimensional que pondera el grado de peligrosidad (por la
combustibilidad) de cada uno de los combustibles (i) que existen en el sector de
incendio.
Ra = coeficiente adimensional que corrige el grado de peligrosidad (por la
activación) inherente a la actividad industrial que se desarrolla en el sector de
incendio, producción, montaje, transformación, reparación, almacenamiento,
etc.
A = superficie construida del sector de incendio o superficie ocupada del área
de incendio, en m2.
Como alternativa a la fórmula anterior se puede evaluar la densidad de
carga de fuego, ponderada y corregida, Qs, del sector de incendio aplicando las
siguientes expresiones:
a) Para actividades de producción, transformación, reparación o cualquier otra
distinta al almacenamiento:
donde:
QS, Ci , Ra y A tienen la misma significación que en el apartado anterior.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
89/106
( )
=
∑=
221
mMj
om
McalA
RhCqS
Qs
n
i
aiivii
qsi = densidad de carga de fuego de cada zona con proceso diferente según los
distintos procesos que se realizan en el sector de incendio (i), en MJ/m2 o
Mcal/m2.
Si = superficie de cada zona con proceso diferente y densidad de carga de
fuego, qsi diferente, en m2.
n= número de procesos diferentes que se llevan a cabo en el sector de
incendios.
Los valores de la densidad de carga de fuego media, qsi, pueden
obtenerse de la tabla 1.2.
b) Para actividades de almacenamiento:
donde:
QS, Ci, Ra y A tienen la misma significación que en el apartado anterior.
qvi = carga de fuego, aportada por cada m3 de cada zona con diferente tipo de
almacenamiento (i) existente en el sector de incendio, en MJ/m3 o Mcal/m3.
hi = altura del almacenamiento de cada uno de los combustibles, (i), en m.
si = superficie ocupada en planta por cada zona con diferente tipo de
almacenamiento (i) existente en el sector de incendio en m2.
n= número de combustibles diferentes almacenados en el sector de incendios.
Los valores de la carga de fuego, por metro cúbico qvi, aportada por cada
uno de los combustibles, pueden obtenerse de la tabla 1.2.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
90/106
( )
=
∑
∑
=
=22
1
1
mMj
om
Mcal
A
AQ
Qen
i
i
n
i
isi
( )
=
∑
∑
=
=22
1
1
mMj
om
Mcal
A
RAQ
Qn
i
ei
n
i
aeiei
E
El nivel de riesgo intrínseco de un edificio o un conjunto de sectores y/o
áreas de incendio de un establecimiento industrial, a los efectos de la aplicación
de este reglamento, se evaluará calculando la siguiente expresión, que
determina la densidad de carga de fuego, ponderada y corregida, Qe, de dicho
edificio industrial.
donde:
Qe = densidad de carga de fuego, ponderada y corregida, del edificio industrial,
en MJ/m2 o Mcal/m2.
Qsi = densidad de carga de fuego, ponderada y corregida, de cada uno de los
sectores o áreas de incendio, (i), que componen el edificio industrial, en MJ/m2
o Mcal/m2.
Ai = superficie construida de cada uno de los sectores o áreas de incendio, (i),
que componen el edificio industrial, en m2.
n= número de sectores o áreas de incendios del edificio.
A los efectos de este reglamento, el nivel de riesgo intrínseco de un
establecimiento industrial, cuando desarrolla su actividad en más de un edificio,
ubicados en un mismo recinto, se evaluará calculando la siguiente expresión,
que determina la carga de fuego, ponderada y corregida, QE, de dicho
establecimiento industrial:
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
91/106
donde:
QE = densidad de carga de fuego, ponderada y corregida, del establecimiento
industrial, en MJ/m2 o Mcal/m2.
Qei = densidad de carga de fuego, ponderada y corregida, de cada uno de los
edificios industriales, (i), que componen el establecimiento industrial en MJ/m2
o Mcal/m2.
Aei = superficie construida de cada uno de los edificios industriales, (i), que
componen el establecimiento industrial, en m2.
n= número de edificios diferentes que componen el establecimiento industrial.
Evaluada la densidad de carga de fuego ponderada, y corregida de un
sector o área de incendio, (QS), de un edificio industrial (Qe) o de un
establecimiento industrial (QE), según cualquiera de los procedimientos
expuestos en los apartados anteriores, el nivel de riesgo intrínseco del sector o
área de incendio, del edificio industrial, o del establecimiento industrial, se
deduce de la tabla 1.3.
A continuación calculamos el nivel de riesgo intrínseco de cada área del
establecimiento:
3.1.2.1 Área de almacenamiento
Esta área se ubica en el edificio de almacenamiento de troncos. En ella se
almacenan los troncos de eucalipto que llegan a la planta. Además en esta
área se realiza el astillado de la madera y un almacenamiento primario de las
astillas. Los datos a tener en cuenta para el cálculo del nivel de riesgo
intrínseco, considerando que es tanto una actividad de almacenamiento como
una actividad de maquinaria, son:
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
92/106
Almacenamiento de troncos:
• Densidad de carga al fuego media (qs) � 6300 MJ/m3
• Riesgo de activación (Ra) � 1,5
• Coef. de peligrosidad por comb. (Ci) � 1,3
• Superficie almacenamiento � 185 m2
• Altura de almacenamiento (h) � 3 m
• Qs � 24570 MJ/m2
Almacenamiento de astillas:
• Densidad de carga al fuego media (qs) � 2100 MJ/m3
• Riesgo de activación (Ra) � 2,0
• Coef. de peligrosidad por comb. (Ci) � 1,3
• Superficie almacenamiento � 25 m2
• Altura de almacenamiento (h) � 5 m
• Qs � 13650 MJ/m2
Maquinaria:
• Densidad de carga al fuego media (qs) � 200 MJ/m2
• Riesgo de activación (Ra) � 1,5
• Coef. de peligrosidad por comb. (Ci) � 1,3
• Superficie � 15 m2
• Qs � 260 MJ/m2
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
93/106
La superficie total del área es 600 m2 y haciendo la combinación las
actividades tenemos que la carga de fuego ponderada para esta área es de
12226 MJ/m2.
3.1.2.2 Área silo principal
Esta área junto al edificio de proceso. En ella se realiza el
almacenamiento de las astillas previo al secado de las mismas. Los datos a
tener en cuenta para el cálculo del nivel de riesgo intrínseco, considerando que
es una actividad de almacenamiento:
• Densidad de carga al fuego media (qs) � 2100 MJ/m3
• Riesgo de activación (Ra) � 2,0
• Coef. de peligrosidad por comb. (Ci) � 1,3
• Superficie almacenamiento � 100 m2
• Altura de almacenamiento (h) � 11 m
• Qs � 30030 MJ/m2
La superficie total del área es 100 m2 y haciendo la combinación las
actividades tenemos que la carga de fuego ponderada para esta área es de
60060 MJ/m2.
3.1.2.3 Área proceso
Esta área en el edificio de proceso. Los datos a tener en cuenta para el
cálculo del nivel de riesgo intrínseco, considerando que es tanto una actividad
de almacenamiento como de maquinaria:
Almacenamiento de astillas:
• Densidad de carga al fuego media (qs) � 2100 MJ/m3
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
94/106
• Riesgo de activación (Ra) � 2,0
• Coef. de peligrosidad por comb. (Ci) � 1,3
• Superficie almacenamiento � 8 m2
• Altura de almacenamiento (h) � 2 m
• Qs � 5460 MJ/m2
Maquinaria:
• Densidad de carga al fuego media (qs) � 200 MJ/m2
• Riesgo de activación (Ra) � 1,5
• Coef. de peligrosidad por comb. (Ci) � 1,3
• Superficie � 500 m2
• Qs � 260 MJ/m2
La superficie total del área es 700 m2 y haciendo la combinación las
actividades tenemos que la carga de fuego ponderada para esta área es de
290 MJ/m2.
3.1.2.4 Área sala de control
Esta área se encuentra en el edificio de proceso. En ella se encuentran los
equipos necesarios para el control del proceso de generación de energía. Los
datos a tener en cuenta para el cálculo del nivel de riesgo intrínseco son:
• Densidad de carga al fuego media (qs) � 600 MJ/m3
• Riesgo de activación (Ra) � 1,5
• Coef. de peligrosidad por comb. (Ci) � 1,0
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
95/106
• Superficie � 100 m2
• Qs � 30030 MJ/m2
La superficie total del área es 100 m2, por lo que la carga de fuego
ponderada para esta área es de 900 MJ/m2.
3.1.2.5 Área de transformación
Esta área se encuentra en el edificio de proceso. En ella se encuentra el
transformador elevador. Los datos a tener en cuenta para el cálculo del nivel
de riesgo intrínseco son:
• Densidad de carga al fuego media (qs) � 300 MJ/m3
• Riesgo de activación (Ra) � 1,5
• Coef. de peligrosidad por comb. (Ci) � 1,3
• Superficie � 100 m2
• Qs � 390 MJ/m2
La superficie total del área es 100 m2, por lo que la carga de fuego
ponderada para esta área es de 585 MJ/m2.
3.1.2.6 Área exterior
Esta área comprende todas las zonas al aire libre del establecimiento,
formada por los viales, zonas de aparcamiento, acerados, y la zona donde se
encuentran el depósito de agua para proceso y las torres de refrigeración. Los
datos a tener en cuenta para el cálculo del nivel de riesgo intrínseco son:
• Densidad de carga al fuego media (qs) � 200 MJ/m3
• Riesgo de activación (Ra) � 1,0
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
96/106
• Coef. de peligrosidad por comb. (Ci) � 1,0
• Superficie � 5946 m2
• Qs � 200 MJ/m2
La superficie total del área es 5946 m2, por lo que la carga de fuego
ponderada para esta área es de 200 MJ/m2.
3.1.2.7 Área caseta de control de acceso
En ella se encuentra la caseta donde se registran las entradas y salidas de
camiones, midiéndose además la humedad de los troncos de entrada y la
cantidad de los mismos. Los datos a tener en cuenta para el cálculo del nivel
de riesgo intrínseco son:
• Densidad de carga al fuego media (qs) � 400 MJ/m3
• Riesgo de activación (Ra) � 1,0
• Coef. de peligrosidad por comb. (Ci) � 1,0
• Superficie � 54 m2
• Qs � 400 MJ/m2
La superficie total del área es 54 m2, por lo que la carga de fuego
ponderada para esta área es de 400 MJ/m2.
3.1.2.8 Área edificio servicios generales
Esta área se regula según el Código Técnico de la Edificación (BOE nº 74
de 28 de marzo de 2006) y su Documento Básico, Seguridad en caso de
incendio (DB-SI), puesto que en ella se realiza una actividad no industrial y el
área construida es superior a 250 m2.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
97/106
El Documento Básico DB-SI especifica parámetros objetivos y
procedimientos cuyo cumplimiento asegura la satisfacción de las exigencias
básicas y la superación de los niveles mínimos de calidad propios del requisito
básico de seguridad en caso de incendio, excepto en el caso de los edificios,
establecimientos y zonas de uso industrial a los que les sea de aplicación el
“Reglamento de seguridad contra incendios en los establecimiento industriales”,
en los cuales las exigencias básicas se cumplen mediante dicha aplicación.
Exigencia básica SI 1: Propagación Interior: se limitará el riesgo de
propagación del incendio por el interior del edificio.
Exigencia básica SI 2: Propagación exterior: se limitará el riego de
propagación del incendio por el exterior, tanto en el edificio considerado como
otros edificios.
Exigencia básica SI 3: Evacuación de ocupantes: el edificio dispondrá de
los medios de evacuación adecuados para que los ocupantes puedan
abandonarlo o alcanzar un lugar seguro dentro del mismo en condiciones de
seguridad.
Exigencia básica SI 4: Instalaciones de protección contra incendios: el
edificio dispondrá de los equipos e instalaciones adecuados para hacer posible
la detección, el control y la extinción del incendio, así como la transmisión de la
alarma a los ocupantes.
Exigencia básica SI 5: Intervención de bomberos: se facilitará la
intervención de los equipos de rescate y de extinción de incendios.
Exigencia básica SI 6: Resistencia al fuego de la estructura: la estructura
portante mantendrá su resistencia al fuego durante el tiempo necesario para
que puedan cumplirse las anteriores exigencias básicas.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
98/106
Compartimentación en sectores de incendio
El edificio de servicios generales constituye un único sector de incendios,
ya que al ser catalogado como de pública concurrencia tiene un área construida
menor que 2500 m2, separado del resto de los edificios industriales mediante
paramentos con la resistencia al fuego requerida en el CT. El área construida
de dicho sector es:
S= 500 m2
Para el cálculo de la densidad carga de fuego emplearemos el ANEJO B.4
del Documento Básico, Seguridad en caso de incendio (DB-SI). El valor de
cálculo de la densidad de carga de fuego se determina en función del valor
característico de la carga de fuego del sector, así como de la probabilidad de
activación y de las previsibles consecuencias del incendio, como:
qf,d =q f,k * m * δq1 * δq2 * δn * δc
siendo:
qf,k valor característico de la densidad de carga de fuego, según B.5.
m coeficiente de combustión que tiene en cuenta la fracción del
combustible que arde en el incendio. En los casos en los que el material
incendiado sea de tipo celulósico (madera, papel, tejidos, etc.) puede tomarse
m= 0,8. Cuando se trate de otro tipo de material y no se conozca su coeficiente
de combustión puede tomarse m=1 del lado de la seguridad.
δq1 coeficiente que tiene en cuenta el riesgo de iniciación debido al
tamaño del sector.
δq2 coeficiente que tiene en cuenta el riesgo de iniciación debido al tipo de
uso o actividad.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
99/106
δn coeficiente que tiene en cuenta las medidas activas voluntarias
existentes, δn = δn1 δn2 δn3
δc coeficiente de corrección según las consecuencias del incendio.
Por tanto, el valor de cálculo de la densidad de carga de fuego del área
SG01-EDIFICIO SERVICIOS GENERALES es:
3.2 Sectorización
La máxima superficie construida admisible de cada sector de incendio
será la que se indica en la siguiente tabla:
Máxima superficie construida admisible de cada sector de incendio
Riesgo intrínseco del sector de incendio Configuración del establecimiento Tipo A m2
Tipo B m2
Tipo C m2
Bajo: (1) (2) (3) (2) (3) (5) (3) (4) 1 2.000 6.000 SIN LÍMITE 2 1.000 4.000 6.000
Medio:
(1) (2) (3) (2) (3) (3) (4) 3 500 3.500 5.000 4 400 3.000 4.000 5 300 2.500 3.500
Alto:
(3) (3) (4) 6
No admitido 2.000 3.000
7 1.500 2.500 8 No admitido 2.000
3.2.1 Sectores de incendio
Un sector de incendio puede estar formado por una o varias áreas de
incendio. En nuestro caso el establecimiento estará formado por cinco sectores
de incendios. A continuación se muestra una tabla donde se enumeran los
2, 6310.187.025.159.11365m
MJq df =⋅⋅⋅⋅⋅=
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
100/106
distintos sectores con las áreas de incendio que los componen, además de los
valores de las cargas de fuego y el nivel de riesgo intrínseco de cada sector.
Cabe destacar que en el sector “servicios generales” no tiene sentido hablar de
nivel de riesgo ni de configuración, ya que este sector se rige por el CTE.
SECTORES ÁREAS QUE LO
FORMAN SUPERFICIE DEL ÁREA
(m2) CARGA DE FUEGO
(MJ/m2) NIVEL DE RIESGO
CONFIGURACIÓN
EXTERIOR EXTERIOR 5946 200
CASETA DE COTROL DE ACCESO
54 400
SECTOR 6000 202 BAJO 1 E
ALMACENAMIENTO ALMACENAMIENTO 600 8151
SECTOR 600 8151 ALTO 7 C
SILO PRINCIPAL SILO PRINCIPAL 100 60060
SECTOR 100 60060 ALTO 8 C
PROCESO PROCESO 700 290
SALA DE CONTROL 50 900
SALA DE TRANSFORMACIÓN
50 585
SECTOR 800 347 BAJO 1 C
SERVICIOS GENERALES
SERVICIOS GENERALES
500 588
SECTOR 500 631 CTE -
Fig. 7: Cálculo de la carga de fuego de las áreas/sectores
3.2.2 Nivel de riesgo del establecimiento
Hasta ahora hemos calculado el nivel de riesgo intrínseco de los sectores
de incendio que componen la instalación completa, por lo que calcularemos a
continuación el nivel de riesgo intrínseco de todo el establecimiento.
( )21587m
MJQE =
El nivel de riesgo intrínseco del establecimiento es por tanto medio 4.
3.3 Instalaciones necesarias
De acuerdo con lo establecido en el Reglamento de Instalaciones de
Protección Contra Incendios en los Establecimientos Industriales 2267/2004, de
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
101/106
3 de Diciembre; en este apartado se cuestiona la necesidad de las
instalaciones y actuaciones para el cumplimiento de la citada norma.
3.3.1 Hidrantes exteriores
Debido a que los sectores de incendios que conforman el establecimiento
tienen una configuración tipo C o E, a que todos los sectores tienen una
superficie inferior a 2000 m2 (excepto el exterior), y puesto que el sector
exterior tiene riesgo intrínseco bajo, no es necesario la instalación de hidrantes
exteriores según el RD 2267/2004.
3.3.2 Red de bocas de incendio equipadas (BIEs)
Según el RD 2267/2004, será necesaria la instalación de una red de BIEs
en el sector ALMACENAMIENTO, puesto que tiene una configuración tipo C, su
nivel de riesgo intrínseco es alto y su superficie total construida es mayor de
500 m2.
Se instalarán dos BIEs de 25 mm con toma de 45 mm, puesto que son
suficientes para cubrir todo el sector.
3.3.3 Rociadores automáticos
Debido a que los sectores de incendios de riesgo intrínseco alto tienen una
superficie inferior a 1000 m2, no es necesaria la instalación de rociadores
automáticos según el RD 2267/2004.
3.3.4 Columna seca
No es necesaria la instalación de sistemas de columna seca según el RD
2267/2004 puesto que la altura de evacuación del establecimiento industrial es
inferior a 15 m.
3.3.5 Sistema de abastecimiento de agua y grupo de bombeo
Será necesaria la instalación de un sistema de abastecimiento de agua
para las BIEs del sector Almacenamiento.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
102/106
El grupo de bombeo estará formado por una bomba eléctrica y una jockey
para la presurización del sistema. Se dispondrá además de un depósito con
agua suficiente para el funcionamiento en continuo de las dos BIEs durante 60
min, que estará destinado exclusivamente a tal fin.
3.3.6 Extintores de incendio
Se instalarán extintores de incendio portátiles en todos los sectores de
incendio, menos en el área exterior ya que es de configuración tipo E y su nivel
de riesgo es bajo 1. Los extintores empleados serán de polvo polivalente ABC
de 6kg, con una eficacia mínima de 34A.
Junto a los cuadros eléctricos se instalarán además extintores de anhídrido
carbónico (CO2) para evitar los posibles conatos de incendio de origen eléctrico,
puesto que los de polvo ABC no se permiten por norma para este fin al ser
conductores de la electricidad.
3.3.7 Detectores automáticos
Según el RD 2267/2004 no es necesario la instalación de detectores
automáticos de incendio en ningún sector, puesto que en los de riesgo
intrínseco bajo no es necesario, los sectores de riesgo intrínseco alto tienen una
superficie menor de 800 m2.
3.3.8 Sistemas manuales de alarma de incendios
Se instalarán sistemas manuales de alarma de incendios (pulsadores) en
todos los sectores de nuestro establecimiento. Se colocarán siempre junto a las
salidas de los diferentes sectores.
3.3.9 Estabilidad al fuego de los elementos constru ctivos portantes
Todos los sectores de incendio cumplirán la estabilidad al fuego que fijada
por el Real Decreto 2267/2004, es decir:
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
103/106
• Sectores de riesgo alto: EF-90
• Sectores de riesgo medio: EF-60
• Sectores de riesgo bajo: EF-30
Además todas las escaleras que sean recorridos de evacuación deben
cumplir con las exigencias anteriores.
Cuando una medianería o un elemento constructivo de compartimentación
en sectores de incendio acometa a la cubierta, la resistencia al fuego de esta
será, al menos, igual a la mitad de la exigida a aquel elemento constructivo, en
una franja cuya anchura sea igual a 1 m. Esta franja podrá encontrarse:
• Integrada en la propia cubierta, siempre que se justifique la permanencia
de la franja tras el colapso de las partes de la cubierta no resistente.
• Fijada en la estructura de la cubierta, cuando esta tenga al menos la
misma estabilidad al fuego que la resistencia exigida a la franja.
• Formada por una barrera de un m de ancho que justifique la resistencia
al fuego requerida y se sitúe por debajo de la cubierta fijada a la
medianería. La barrera no se instalará en ningún caso a una distancia
mayor de 40 cm de la parte inferior de la cubierta.
No obstante, si la medianería o el elemento compartimentador se prolonga
un metro por encima de la cubierta, como mínimo, no es necesario que la
cubierta cumpla la condición anterior.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
104/106
3.3.10 Evacuación
• Recorridos de evacuación:
Las distancias máximas de los recorridos de evacuación de los sectores de
incendio no superarán los valores indicados en el Real Decreto 2267/2004,
serán los siguientes:
Riesgo 1 salida recorrido único 2 salidas alternativas
Bajo 35 m (*) 50 m
Medio 25 m (**) 50 m
Alto - 25 m
(*) La distancia se podrá aumentar a 50 m si la ocupación es inferior a 25
personas.
(**) La distancia se podrá aumentar a 35 m si la ocupación es inferior a
25 personas.
• Puertas de evacuación:
Las puertas situadas en los recorridos de las vías de evacuación abrirán
siempre en el sentido de la evacuación y se deberán poder abrir en cualquier
momento desde el interior sin ayuda especial.
Las puertas de evacuación deberán ser abatibles, de eje vertical y con una
anchura de al menos 80 cm. Estas puertas no pueden estar instaladas sobre los
portones para vehículos, sean estos motorizados o no. Los portones para
vehículos no se considerarán salidas de evacuación.
El mecanismo de apertura de las puertas de de evacuación la planta serán
barras de emergencia conforme a UNE EN 1125 en los sectores de mayor
ocupación. En el resto de zonas pueden instalarse manillas o pulsadores
conforme UNE EN 179.
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
105/106
• Alumbrado de emergencia:
El alumbrado de emergencia se realizará de acuerdo a lo especificado en
el apartado “3.16. Instalación de alumbrado” de la Especificación General de
Equipos Electromecánicos, electricidad, control e instrumentación.
La instalación de alumbrado de emergencia se diseñará de acuerdo con lo
indicado en la ITC-BT-028 del REBT y el CTE.
Para otros casos, se establecerán como mínimo los requerimientos
siguientes en su diseño:
Niveles de iluminación:
Tipo de alumbrado Nivel de iluminación Alumbrado de evacuación para reconocer y utilizar las
rutas de evacuación en los ejes de los pasos principales (medido en el suelo)
1 lux
Alumbrado de evacuación para identificar los puntos de los servicios contra incendios (puestos de control locales y
BIEs) y cuadros locales de fuerza y alumbrado 5 lux
Alumbrado de ambiente para identificar y acceder a las rutas de evacuación 0,5 lux
Alumbrado de reemplazamiento en salas eléctricas. 150 lux (50 % del alumbrado de la sala)
Alumbrado de reemplazamiento en salas de control. 250 lux (50 % del alumbrado de la sala)
La instalación de los sistemas de alumbrado de emergencia será fija,
estará provista de fuente propia de energía y será capaz de mantener la
intensidad indicada en cada caso al menos durante una hora.
• Señalización:
Se señalizarán todas las salidas de uso habitual y de emergencia, así como
los medios de protección contra incendios de utilización manual, según la
norma UNE 23034 y en base a los siguientes criterios:
CÁLCULOS
PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW
106/106
a) Las salidas de recinto, planta o edificio de más de 50 m2 tendrán
una señal con el rótulo “SALIDA”, que serán fácilmente visibles
desde todo punto de dichos recintos.
b) La señal con el rótulo “Salida de emergencia” se utilizará en toda
salida prevista para uso exclusivo en caso de emergencia.
c) Se dispondrá de señales indicativas de dirección de los recorridos,
visibles desde todo origen de evacuación desde el que no se
perciban directamente las salidas o sus señales indicativas.
d) En los puntos de los recorridos de evacuación en los que existan
alternativas que puedan inducir a error, también se dispondrán las
señales antes citadas, de forma que quede claramente indicada la
alternativa correcta. Tal es el caso de determinados cruces o
bifurcaciones de pasillos, así como de aquellas escaleras que, en la
planta de salida del edificio, continúen su trazado hacia plantas más
bajas, etc.
e) En dichos recorridos, junto a las puertas que no sean salida y que
puedan inducir a error en la evacuación debe disponerse la señal
con el rótulo “SIN SALIDA” en lugar fácilmente visible.
f) Las señales se instalarán a una altura y en una posición apropiadas
en relación al ángulo visual, teniendo en cuenta posibles
obstáculos.
g) Bajo ningún pretexto se colocarán las señales en las hojas de las
puertas, ya que, en caso de que ésta quedase abierta no sería
visible.